CMS ECAL Phase-2 upgrade: characterisation and stability analysis of a three-stage low-voltage power-conversion system
physics.ins-det, cs.SY, eess.SY, hep-ex
Submitted: 2026-11-04
Updated: 2026-11-04
Comments: 7 pages, 6 figures. Proceedings of the Topical Workshop on Electronics for Particle Physics (TWEPP 2026), 28 September - 2 October 2026, Castelldefels, Spain. Submitted to JINST
License: http://creativecommons.org/licenses/by/4.0/
The gist: As part of the High-Luminosity upgrade of the Large Hadron Collider, the front-end electronics of the Compact Muon Solenoid electromagnetic calorimeter barrel are being replaced.
Terminology
Abstract
As part of the High-Luminosity upgrade of the Large Hadron Collider, the front-end electronics of the Compact Muon Solenoid electromagnetic calorimeter barrel are being replaced. A three-stage low-voltage power-conversion system supplies the upgraded electronics. As the cascade dynamics require characterisation to ensure stable operation, interactions between the three converter stages are assessed at their two interfaces using the Nyquist criterion. A validated shunt-injection setup using a Bode 100 frequency-response analyser provides in-situ impedance measurements under load to assess the accuracy of the averaged converter models. Results show that both interfaces are stable over the evaluated configurations, with modelled minimum distances to the critical point of 0.76 and 0.79, respectively. A turn-on study identifies capacitor charging at Stage 3 as the main cause of inrush currents triggering Stage 2 overcurrent protection. Two Stage 3 board variants stagger converter enables within and between boards, keeping the measured two-tower current below 5 A, within the 8.0 A protection threshold.
Related papers
- Cryogenic Mechanical Loss of GaAs/AlGaAs Crystalline Coatings
- The physical design of the superfluid helium-4 UCN source at CSNS
- A new diffuse reflector filament for additive manufacturing of 3D printing finely-segmented plastic scintillator
- Characterization of CRYO ASIC for charge readout in the nEXO experiment
- Reconstructing High-Fidelity Light Yield Maps for Surface LArTPCs Using Crossing Cosmic Muons
- OASIS-ERIS: Open Acquisition System for IEPE Sensors - Electrically Refined and Inter-device Synchronization