Characterization of CRYO ASIC for charge readout in the nEXO experiment
Listen
Radio episode about this paper
Transcript
Introduction to the show: ident: Physics. The day in general physics: instruments, methods and results across the field.
Kai: I'm Kai.
Mira: And I'm Mira, here with Lev.
Kai: We're looking at the paper: "Characterization of CRYO ASIC for charge readout in the nEXO experiment".
Mira: Here's the gist of the paper. nEXO is a proposed next-generation experiment searching for neutrinoless double beta decay of 136Xe using a tonne-scale liquid xenon (LXe) time projection chamber (TPC) The CRYO ASIC achieves the desired performance at LXe temperatures, showing relative response variations below 0.2% for nearly all channels during a 14-hour interval These results establish CRYO ASIC as a viable low-noise in-LXe charge readout solution for nEXO ASIC Design and Functionality The CRYO ASIC is a System-on-Chip (SoC) waveform digitizer and serializer implemented in TSMC’s 130 nm CMOS process, designed specifically for noble liquid TPC experiments The ASIC integrates both analog and digital functions into a single chip, providing 64 input channels each sampled at 2 MSPS with 12-bit resolution across a 1.6 V range Data are read at a rate of 896 Mbps The design minimizes the need for external components by employing on-chip supply regulation by distributing low-dropout (LDO) voltage regulators across the chip CRYO ASIC has been designed using known best-practices for extended operation in cryogenic temperatures
5: and enables the user to correct for temperature-dependent effects by directly programming the voltage levels in core sections through internal registers Cryogenic Testing and Stability The initial performance of CRYO ASIC are demonstrated in the gas-nitrogen environmental chamber with both Cold Board and the FEMB boards The optimized register settings for the LXe temperature is then applied to all tests presented in this work The pulse response of the FEMB board is verified by enabling the internal pulser on ASICs, as illustrated in the block diagram in Fig.
Kai: 1, using configurations with four different peaking times The channel gains are measured once per hour using both the internal and the external pulser calibration systems The average amplitudes of both systems calibrated on one representative channel (channel 27) are shown in the lower left panel of Fig.
Mira: 5, where the two gain-variation curves track each other well which indicates the ability of self-calibration by the internal pulses In-LXe Noise Performance Significant boiling is observed after the CRYO ASIC is powered on, once the LXe conditions stabilize at a pressure of 0.095 MPa and a temperature of 170.45 K, as shown in the left panel of Fig.
Kai: 6 The mitigation of LXe boiling is confirmed by both the camera monitoring and the CRYO ASIC noise measurements Under these conditions, the ASIC achieves an average noise performance of 156 e− ENC at a gain of 28.6 mV/fC, a peaking time of 1.
Paper summary: Kai: So, this paper is about testing a chip called CRYO ASIC for reading out signals in the nEXO experiment.
Mira: It's basically checking if this specific piece of hardware can actually handle the liquid xenon conditions it needs to work in.
Kai: The authors are looking at how stable this chip is when you run it at those very low temperatures and pressures.
Mira: They are showing that the response variations stay below point zero two percent for nearly all channels over a fourteen hour period in liquid xenon.
Kai: That level of stability, if they can maintain it under real detector conditions, means we have a much more reliable way to measure the tiny signals they're looking for.
Mira: But we need to remember the big picture here, this chip is just one part of a tonne-scale experiment searching for neutrinoless double beta decay.
Kai: Right, so it’s not about finding the decay itself right now, but making sure we have a trustworthy tool to measure what happens if it does occur.
Mira: The main implication is that this chip proves it’s viable as a low-noise readout solution for the nEXO experiment.
Kai: And they're setting up the next steps to see how this component fits into the whole detector design and overall system performance.
Conclusion: Kai: So we're wrapping up this look at the "Characterization of CRYO ASIC for charge readout in the nEXO experiment."
Mira: Basically, they're showing that this specific chip can handle the liquid xenon environment well enough to be a reliable readout component.
Kai: The authors are focused on proving that this hardware works under those specific low temperatures and pressures they need.
Mira: They demonstrate that the response variations stay below zero point two percent for almost every channel over a fourteen hour test period in liquid xenon.
Kai: That level of stability means we have a much more dependable way to measure those tiny signals they're hunting for in the experiment.
Mira: But we gotta remember this chip is just one part of the whole thing, which is searching for neutrinoless double beta decay across a tonne-scale detector.
Kai: Right, so the main point isn't finding that decay right now, but making sure we have a trustworthy tool ready to measure it when it happens.
Mira: The big takeaway here is that this chip proves itself viable as a low-noise readout solution for the nEXO experiment.
Kai: And they’re already planning what comes next, figuring out how this component fits into the overall detector design and system performance.
Mira: That leads us right into whether this chip can actually handle the scale and complexity required for a tonne-scale search.
University of Hawaii at Manoa · SLAC National Accelerator Laboratory · Stanford University · Drexel University · University of California San Diego · University of Alabama · È Amherst Center for Fundamental Interactions and Physics Department, University of Massachusetts Amherst Center for Fundamental Interactions and Physics Department, University of Massachusetts Amherst Center for Fundamental Interactions and Physics Department, University of Massachusetts Amherst Center for Fundamental Interactions and Physics Department, University of Massachusetts Amherst Center for Fundamental Interactions and Physics Department, University of Massachusetts Amherst Center for Fundamental Interactions and Physics Department · Pacific Northwest National Laboratory · Université de Sherbrooke · National Research Center “Kurchatov Institute” · Lawrence Livermore National Laboratory · ž McGill University · ƒ SNOLAB Lively, ON P3Y 1N2 Canada · Institute of High Energy Physics, Chinese Academy of Sciences Beijing, 100049 China · Institute of Microelectronics, Chinese Academy of Sciences Beijing, 100029 China · Department of Physics and Astronomy University of Kentucky Lexington KY 40506 USA · Brookhaven National Laboratory Upton NY 11973 USA · Rensselaer Polytechnic Institute Troy NY 12180 USA · ž TRIUMF Vancouver BC V6T 2A3 Canada · Department of Physics and Astronomy University of Windsor Windsor ON N9B 3P4 Canada · Oak Ridge National Laboratory Oak Ridge TN 37831 USA · Colorado School of Mines Golden CO 80401 USA
physics.ins-det, nucl-ex
Submitted: 2025-12-11
Updated: 2026-11-10
Code: https://github.com/slaclab/surf
Project page: https://slaclab.github.io/rogue
License: http://creativecommons.org/licenses/by/4.0/
Importance score: 99/100
The gist: nEXO is a proposed next-generation experiment searching for neutrinoless double beta decay of 136Xe using a tonne-scale liquid xenon (LXe) time projection chamber (TPC) The CRYO ASIC achieves the…
Key concepts
- CRYO ASIC
- This is the System-on-Chip device designed to digitize and serialize charge signals from the liquid xenon detector. It integrates analog and digital functions onto a single chip, using 64 channels sampled at 2 MSPS with 12-bit resolution, while minimizing external components through on-chip power regulation.
- LXe Boiling Mitigation
- When the CRYO ASIC is powered on in liquid xenon (LXe) conditions, significant boiling occurs. The experiment confirmed that monitoring and noise measurements allowed for successful mitigation of this boiling effect once the LXe stabilized at 170.45 K.
- ENC
- Electronic Noise Charge (ENC) is a key metric used to assess the noise performance of the readout system. The ASIC achieved an average ENC of 156 e- at a gain of 28.6 mV/fC, indicating its low noise capability for detecting rare events in the experiment.
Terminology
Summary
nEXO is a proposed next-generation experiment searching for neutrinoless double beta decay of 136Xe using a tonne-scale liquid xenon (LXe) time projection chamber (TPC) The CRYO ASIC achieves the desired performance at LXe temperatures, showing relative response variations below 0. p. 2 Abstract: nEXO is a proposed next-generation experiment searching for the neutrinoless double
beta decay of 136Xe using a tonne-scale liquid xenon (LXe) time projection chamber (TPC). To
image the ionization signals from events in the LXe, the detector will employ metallized fusedsilica charge collection tiles instrumented with cryogenic application-specific integrated circuits
(ASICs), referred to as CRYO ASIC, which are designed to operate directly in LXe to minimize
input capacitance and pick-up noise.Where the paper says it
ASIC Design and Functionality
The CRYO ASIC is a System-on-Chip (SoC) waveform digitizer and serializer implemented in TSMC’s 130 nm CMOS process, designed specifically for noble liquid TPC experiments The ASIC integrates both analog and digital functions into a single chip, providing 64 input channels each sampled at 2 MSPS with 12-bit resolution across a 1.6 V range Data are read at a rate of 896 Mbps The design minimizes the need for external components by employing on-chip supply regulation by distributing low-dropout (LDO) voltage regulators across the chip CRYO ASIC has been designed using known best-practices for extended operation in cryogenic temperatures [5] and enables the user to correct for temperature-dependent effects by directly programming the voltage levels in core sections through internal registers
Cryogenic Testing and Stability
The initial performance of CRYO ASIC are demonstrated in the gas-nitrogen environmental chamber with both Cold Board and the FEMB boards The optimized register settings for the LXe temperature is then applied to all tests presented in this work The pulse response of the FEMB board is verified by enabling the internal pulser on ASICs, as illustrated in the block diagram in Fig. 1, using configurations with four different peaking times The channel gains are measured once per hour using both the internal and the external pulser calibration systems The average amplitudes of both systems calibrated on one representative channel (channel 27) are shown in the lower left panel of Fig. p. 9 The channel gains are measured once per hour using both the internal and
the external pulser calibration systems. The external pulse generator and associated cabling adds
significant noise to the input when connected, and several grounding configurations were tested to
minimize pickup noise to acceptable levels (∼ 20 ADC RMS).Where the paper says it
In-LXe Noise Performance
Significant boiling is observed after the CRYO ASIC is powered on, once the LXe conditions stabilize at a pressure of 0.095 MPa and a temperature of 170. p. 4 To comply with the stringent lowradioactivity requirements, the design minimizes the need for external components by employing
on-chip supply regulation by distributing low-dropout (LDO) voltage regulators across the chip. CRYO ASIC has been designed using known best-practices for extended operation in cryogenic
temperatures [5], and enables the user to correct for temperature-dependent effects by directly
programming the voltage levels in core sections through internal registers. Data is transmitted using a custom high-speed cable from SAMTEC. 2 Cryogenic test stands
A liquid-nitrogen-cooled environmental chamber [12], shown in the left panel of Fig. 2 Study of boiling conditions during LXe operation 8
3. 3 Noise measurements with CRYO ASIC in LXe 9
4 Summary and outlook 10
5 Acknowledgments 11
1 Introduction
The nEXO experiment is a proposed next-generation search for neutrinoless double beta decay
(0𝜈𝛽𝛽), aiming to achieve a half-life sensitivity beyond 1028 years using an isotopically-enriched
liquid xenon (LXe) time projection chamber (TPC) [1]. The ASIC integrates both analog and digital functions into a single chip, providing 64 input channels
each sampled at 2 MSPS with 12-bit resolution across a 1. The gain and peaking time of
the front end are configurable between four different values each to optimize between resolution,
dynamic range, and noise.Where the paper says it
Where the paper says it
Where the paper says it
Where the paper says it
Green — the paper says it, and the page is printed. Red — no passage carries it, so treat that sentence as unverified. The same check runs on your own text: check a summary against its source, $5.
Improvements for AI systems
-
System can achieve low-noise in-LXe charge readout by employing CRYO ASIC which is
designed to operate directly in LXe to minimize input capacitance and pick-up noise.
This allows for a noise level of 156 e minus ENC at a gain of 28.6 mV/fC and a peaking time of 1.2 us with an input capacitance of 22 pF. -
System can mitigate LXe boiling to enable stable in-LXe operation by
operating the system above ~0.1 MPa,
which is confirmed to be sufficient for nEXO operating conditions around 0.15 MPa, as the resultsindicate that the CRYO ASIC will not induce boiling under the planned detector operating conditions.
-
System can perform periodic in-situ calibration of channel response by utilizing an
internal pulser system
which can be used to track charge response, and gains calibrated by both internal and external pulsers are shown to satisfy the "<0.2% variation requirement for nEXO."
Abstract
nEXO is a proposed next-generation experiment searching for the neutrinoless double beta decay of 136 Xe using a tonne-scale liquid xenon (LXe) time projection chamber (TPC). To image the ionization signals from events in the liquid xenon, the detector will employ metallized fused-silica charge collection tiles instrumented with cryogenic application-specific integrated circuits (ASICs), referred to as CRYO ASIC, which are designed to operate directly in LXe to minimize input capacitance and pick-up noise. Here we present the performance of the CRYO ASIC mounted on an auxiliary printed circuit board and evaluated both in a cryogenic environmental chamber and in a dedicated LXe test stand. We demonstrate that the ASICs achieve the desired performance at liquid xenon temperatures, showing a gain stability better than 0.2% over 24-hour operation and reliable in-situ calibration using an on-chip pulser. In the LXe test stand, we show that boiling caused by the chip heat dissipation can be mitigated by operating the system above 0.1 MPa. The in-LXe noise measured agrees with simulation, which indicates it the 150 e- design requirement can be satisfied. These results establish CRYO ASIC as a viable low-noise in-LXe charge readout solution for nEXO.
Sources
- NEXO: Neutrinoless double beta decay search beyond $10^{28}$ year half-life sensitivity
- A flexible test facility for liquid xenon detector development
- The EXO-200 detector, part II: Auxiliary Systems
- Measurement of the onset of nucleate boiling in liquid xenon
- Ultra-low radioactivity flexible printed cables
- nEXO Pre-Conceptual Design Report
Related papers
- Cryogenic Mechanical Loss of GaAs/AlGaAs Crystalline Coatings
- The physical design of the superfluid helium-4 UCN source at CSNS
- A new diffuse reflector filament for additive manufacturing of 3D printing finely-segmented plastic scintillator
- Reconstructing High-Fidelity Light Yield Maps for Surface LArTPCs Using Crossing Cosmic Muons
- OASIS-ERIS: Open Acquisition System for IEPE Sensors - Electrically Refined and Inter-device Synchronization
- Low-energy nuclear recoil calibration of the LUX-ZEPLIN experiment with a photoneutron source