The gist: The muon transfer method allows access to radioactive/rare atomic nuclei for determining their charge radii via muonic x-ray spectroscopy.
Abstract
The muon transfer method allows access to radioactive/rare atomic nuclei for determining their charge radii via muonic x-ray spectroscopy. In this study we present a new muon transfer cell based on liquid hydrogen optimized for low-energy x-ray spectroscopy by employing a thin-walled Mylar cell for the container of the liquid hydrogen. Based on simulations, the present liquid hydrogen cell achieves competitive efficiencies compared to existing devices using the muon transfer method. Additionally, the liquid-hydrogen-based muon transfer setup provides a short timescale for the diffusion process of the muonic hydrogen atoms in the cell, well below 200~ns.
Related papers
- Cryogenic Mechanical Loss of GaAs/AlGaAs Crystalline Coatings
- The physical design of the superfluid helium-4 UCN source at CSNS
- A new diffuse reflector filament for additive manufacturing of 3D printing finely-segmented plastic scintillator
- Characterization of CRYO ASIC for charge readout in the nEXO experiment
- Reconstructing High-Fidelity Light Yield Maps for Surface LArTPCs Using Crossing Cosmic Muons