Imaging performance of a Single-Plane Readout Compton Camera
Listen
Radio episode about this paper
Transcript
Introduction to the show: ident: Physics. The day in general physics: instruments, methods and results across the field.
Kai: We're looking at the paper: "Imaging performance of a Single-Plane Readout Compton Camera".
Mira: Here's the gist of the paper. This work presents the design, development, and characterization of a compact Compton camera employing a novel single-plane readout architecture.
Kai: The proposed concept simplifies conventional multilayer Compton cameras by optically coupling the scatterer and absorber into a single compact detector element using a light guide, enabling readout exclusively from one side with silicon photomultipliers.
Mira: System Design and Architecture The prototype comprises 64 detector elements arranged in an 8 × 8 matrix, read out by an 8 × 8 silicon photomultiplier array.
Kai: Each element consists of two GAGG:Ce scintillators coupled by a 20 mm long light guide.
Paper summary: Kai: So we've just covered the basic setup described in this paper, which focuses on designing and characterizing a compact Compton camera using a novel single-plane readout architecture.
Mira: This architecture simplifies traditional multilayer Compton cameras by optically coupling the scatterer and absorber into one single compact detector element using a light guide.
Lev: The core claim is that this optical coupling enables readout exclusively from one side with silicon photomultipliers, which is a significant simplification over conventional designs.
Kai: And they validated this concept through Monte Carlo simulations, prototype construction, and experimental characterization using standard gamma-ray sources to optimize the event selection strategy.
Mira: They used these simulations based on the Geant4 framework to optimize performance specifically for five hundred eleven keV and six hundred sixty-two keV photons during the guiding of event selection <ref:2609.20841#pg1,for 511 keV and 662 keV photons>.
Lev: The reconstruction part relies on coincidence detection consistent with Compton scattering kinematics, and then image reconstruction is performed using a maximum likelihood expectation maximization algorithm.
Kai: They optimized the system by choosing an inter-pixel distance cut of ten millimeters for one hundred thirty seven cesium and thirteen millimeters for two hundred twenty sodium to improve the result.
Mira: That strict event selection process helped them get about eighty one percent of correctly reconstructed events, which they found quite effective.
Lev: I’m thinking about scaling this up; what does that eighty one percent efficiency take to run on real hardware, and where does the overhead really land compared to a full array.
Kai: The prototype itself is an eight by eight matrix of sixty four detector elements, with each element having two GAGG:Ce scintillators coupled by a twenty millimeter long light guide <ref:2609.20841#pg1>.
Mira: They chose GAGG:Ce scintillators for both the scatterer and absorber because they offer high light yield, high density, and a good atomic number for interaction probability.
Lev: From an engineering view, I'm curious about the physical assembly; how were these elements arranged in the housing with ESR sheets and vertical strips inserted between them?
Kai: The readout electronics are built around a sixty four channel silicon photomultiplier array connected to a TOFPET2 data acquisition system. That’s how they capture the signal from those detectors.
Mira: They measured energy resolutions of eight point nine percent plus one point nine percent for the front layer and ten point eight percent plus one point six percent for the back layer. Those are key performance metrics here.
Lev: So, to summarize this section: they've built a physical prototype demonstrating a compact system with single-plane readout and measured those energy resolutions using the specified scintillators.
Kai: And they also report their angular resolutions, which were twelve point four degrees minus fourteen point three degrees at five hundred eleven keV and fourteen point three degrees minus sixteen point eight degrees at six hundred sixty two keV.
Mira: So, this paper establishes the baseline performance metrics for this specific single-plane readout Compton camera design.
Lev: That sets a benchmark for what we need to consider when moving from simulation to something that can actually run on real hardware, especially concerning those reconstruction algorithms they mentioned.
Conclusion: Kai: So looking at the title "Imaging performance of a Single-Plane Readout Compton Camera", this paper is essentially presenting a working design and characterization of this compact camera concept.
Mira: The authors are showing how to simplify conventional multilayer cameras by using a light guide for coupling and enabling single-sided readout with siPMs.
Lev: The implication here is that we can achieve better field-of-view than older mechanical collimator based systems without sacrificing too much sensitivity through Compton scattering kinematics two <ref:2609.20841#pg2>.
Kai: It confirms that this approach is feasible for achieving gamma-ray imaging in various fields like environmental monitoring or homeland security.
Mira: This work shows the performance metrics achieved at specific energies, such as twelve point four degrees minus fourteen point three degrees for five hundred eleven keV and fourteen point three degrees minus sixteen point eight degrees for six hundred sixty two keV photons.
Lev: It highlights the trade-off between achieving good spatial resolution and maintaining the overall efficiency of correctly reconstructed events.
Kai: The paper is a demonstration that we can develop more compact, lower-cost detectors for source localization in portable applications.
Mira: Overall, it shows a reliable method for building these systems using single-plane readout and GAGG:Ce scintillators.
University of Zagreb Faculty of Science Department of Physics
physics.ins-det
Submitted: 2026-08-03
Updated: 2026-11-11
Comments: This work has been accepted for publication in IEEE Transactions on Nuclear Science
License: http://creativecommons.org/licenses/by/4.0/
Importance score: 77/100
The gist: This work presents the design, development, and characterization of a compact Compton camera employing a novel single-plane readout architecture.
Key concepts
- Single-Plane Readout Architecture
- This is a new design where the scatterer and absorber are combined into a single compact detector unit using a light guide. Instead of reading out from multiple sides, the system is designed to be read exclusively from one side using silicon photomultipliers (SiPMs), which simplifies the electronics and reduces complexity.
- GAGG:Ce Scintillators
- These are special scintillating materials chosen for both parts of the camera. They offer high light yield, meaning they produce a strong signal when hit by gamma rays, high density, and a good atomic number. These properties ensure efficient interaction with gamma rays and good image quality.
- LM-MLEM Algorithm
- This is a mathematical method used to reconstruct the original source distribution from the measured data. List-mode Maximum Likelihood Expectation Maximization (LM-MLEM) helps determine where the gamma rays originated by comparing what was actually detected with what a model predicts, improving image accuracy.
- SiPM Array
- Silicon Photomultipliers are the sensors used to read out the light signals from the detector elements. They convert light into measurable electrical pulses. An array of these SiPMs forms the readout system for the 64 detector elements, allowing for precise measurement of gamma-ray interactions.
Terminology
Summary
This work presents the design, development, and characterization of a compact Compton camera employing a novel single-plane readout architecture. p. 0 Imaging performance of a Single-Plane Readout
Compton Camera∗
Om Prakash Dash, Tomislav Bokulić, Damir Bosnar,
and Mihael Makek†
University of Zagreb Faculty of Science, Department of Physics,
Zagreb, 10000, Croatia
Abstract
This work presents the design, development, and characterization of a
compact Compton camera employing a novel single-plane readout architecture. The proposed concept simplifies conventional multilayer Compton cameras by optically coupling the scatterer and absorber into a single compact detector element using a light guide, enabling readout exclusively from one side with silicon photomultipliers. Imaging performance of a Single-Plane Readout
Compton Camera∗
Om Prakash Dash, Tomislav Bokulić, Damir Bosnar,
and Mihael Makek†
University of Zagreb Faculty of Science, Department of Physics,
Zagreb, 10000, Croatia
Abstract
This work presents the design, development, and characterization of a
compact Compton camera employing a novel single-plane readout architecture. The proposed concept simplifies conventional multilayer Compton cameras by optically coupling the scatterer and absorber into a single compact detector element using a light guide, enabling readout exclusively from one side with silicon photomultipliers.Where the paper says it
Where the paper says it
System Design and Architecture
The prototype comprises 64 detector elements arranged in an 8 × 8 matrix, read out by an 8 × 8 silicon photomultiplier array. Each element consists of two GAGG:Ce scintillators coupled by a 20 mm long light guide. p. 0 The prototype comprises 64 detector elements arranged in an 8 × 8 matrix, read out by an 8 × 8 silicon photomultiplier array. Each element
consists of two GAGG:Ce scintillators coupled by a 20 mm long light
guide. The matrix was assembled row by row. ESR sheets were placed along the
inner walls of the housing, followed by placement of eight pixels per row. The SiPM array was then connected to the TOFPET2
[27] data acquisition system for testing and characterization. 3 Readout Electronics
Data acquisition was performed using the TOFPET2 ASIC, a high-performance
readout and digitization chip optimized for Silicon Photomultiplier (SiPM) signals.Where the paper says it
Where the paper says it
Where the paper says it
Detector Material Selection and Performance
GAGG:Ce scintillators were chosen for both the scatterer and absorber elements due to their high light yield, high density, and effective atomic number which provide a high gamma-ray interaction probability. The measured energy resolutions were 8. p. 0 Each element
consists of two GAGG:Ce scintillators coupled by a 20 mm long light
guide. Measured energy resolutions were 8. 4 Measurements and Data Processing
The detector consists of two GAGG:Ce layers arranged in a sandwiched geometry and read out from one side by a SiPM array. The layer adjacent to the
SiPM is referred to as the back layer, while the opposite layer is defined as the
front layer. 4 Measurements and Data Processing
The detector consists of two GAGG:Ce layers arranged in a sandwiched geometry and read out from one side by a SiPM array. The layer adjacent to the
SiPM is referred to as the back layer, while the opposite layer is defined as the
front layer. 6%
for the front and back layers, respectively. Successful gamma-ray imaging
was demonstrated for Na-22 and Cs-137 sources, achieving angular resolutions of 12. The system was
validated through Monte Carlo simulations, prototype construction, and
experimental characterization using standard gamma-ray sources. Detector performance for 511 keV and 662 keV photons was optimized using
simulations based on the Geant4 framework, by guiding event selection
strategy. The system was
validated through Monte Carlo simulations, prototype construction, and
experimental characterization using standard gamma-ray sources. Detector performance for 511 keV and 662 keV photons was optimized using
simulations based on the Geant4 framework, by guiding event selection
strategy.Where the paper says it
Where the paper says it
Where the paper says it
Where the paper says it
Where the paper says it
Where the paper says it
Experimental Validation and Analysis
The detector characterization involved two measurement campaigns, first for energy calibration and second for imaging characterization. The analysis employed a list-mode Maximum Likelihood Expectation Maximization (LM-MLEM) algorithm to reconstruct the source distribution. p. 4 In simple back-projection (BP), the reconstructed image is formed by directly
back-projecting the measured Compton cones into the image space. Maximum
Likelihood Expectation Maximization (MLEM) reconstructs the same image
iteratively using a statistical model of the imaging system, where repeated forward projection and back-projection refine the activity distribution, typically
resulting in improved localization, contrast, and reduced image artifacts. Dataset Purpose Source Position Distance Duration
1 Low-energy calibration 241Am (59. 4 keV) Center (front) In contact 24 h
2 Low-energy calibration (partial) 241Am Left / Right sides Side exposure 24 h (each)
3 Photopeak calibration 22Na (511 keV) Right (front & back) Side exposure 24 h
4 Photopeak calibration 137Cs (662 keV) Right front (a) & back (b) Side exposure 24 h
5 Photopeak calibration 137Cs (662 keV) Right front (a) & back (b) Side exposure 24 h
6 Imaging (central) 137Cs (0, 0) 5 cm 24 h
7 Imaging (central) 137Cs (0, 0) 10 cm 24 h
8 Imaging (off-axis) 137Cs (0 mm, ±10 mm), (±8 mm, ±8 mm) 10 cm 24 h (each)
9 Imaging (central) 22Na (0, 0) 10 cm 24 h
10 Imaging (off-axis) 22Na (0, 0), (10 mm, 0), (30 mm, 0) 10 cm 24 h (each)
10 1:
cos θg =
(P1 − P0) · (P2 − P1)
|P1 − P0| |P2 − P1|
. (4)
The ARM distribution is centered around zero for correctly reconstructed
events, and its full width at half maximum (FWHM) is used as a measure of
the system angular resolution.Where the paper says it
Where the paper says it
Where the paper says it
Imaging Results and Conclusions
The reconstructed images confirmed that the source position is correctly reconstructed in both X and Y directions with the positioning and imaging accuracy. Angular resolutions of 14. p. 0 6%
for the front and back layers, respectively. Successful gamma-ray imaging
was demonstrated for Na-22 and Cs-137 sources, achieving angular resolutions of 12. The system was
validated through Monte Carlo simulations, prototype construction, and
experimental characterization using standard gamma-ray sources. Detector performance for 511 keV and 662 keV photons was optimized using
simulations based on the Geant4 framework, by guiding event selection
strategy. The system was
validated through Monte Carlo simulations, prototype construction, and
experimental characterization using standard gamma-ray sources. Detector performance for 511 keV and 662 keV photons was optimized using
simulations based on the Geant4 framework, by guiding event selection
strategy. 3
◦
–16. 8
◦
at 662 keV, confirming
the feasibility of the proposed single-plane architecture for compact and
cost-effective gamma-ray imaging applications.Where the paper says it
Where the paper says it
Where the paper says it
Where the paper says it
References
[1] H. O. Anger, “Scintillation camera,” Rev. p. 1 In particular, gamma-ray imaging plays a critical role in medical
diagnostics through techniques such as Positron Emission Tomography (PET)
and Single-photon Emission Computed Tomography (SPECT), as well as in
the detection and localization of radioactive materials in environmental and
security-related scenarios. Conventional gamma-ray imaging systems, such as Anger cameras, rely
on mechanical collimators to determine the direction of incoming photons [1].Where the paper says it
[2] A. H. Compton, “A quantum theory of the scattering of X-rays by light elements,” Phys. p. 6 Silicon photomultiplier arrays from Hamamatsu (S13361-3050AE-08) was chosen owing to the fair compatibility of its quantum efficiency with the GAGG
emission spectrum. To enhance light collection efficiency and prevent optical cross-talk between
adjacent detector elements, 3M™ Enhanced Specular Reflector (ESR) film was
7Where the paper says it
[3] V. Schönfelder, A. p. 1 Compton cameras aim to overcome these limitations by exploiting the kinematics of Compton scattering [2]
to perform electronic collimation, enabling wider field-of-view, and improved
sensitivity. Since their first proposal by Schönfelder et al. The proposed concept simplifies conventional multilayer Compton cameras by optically coupling the scatterer and absorber into a single compact detector element using a light guide, enabling readout exclusively from one side with silicon photomultipliers. The system was
validated through Monte Carlo simulations, prototype construction, and
experimental characterization using standard gamma-ray sources.Where the paper says it
Where the paper says it
[4] R. W. Todd, J. M. Nightingale, and D. B. Everett, A proposed γ camera,
Nature, vol. 251, no. 5471, pp. 132–134, 1974
[5] S. Watanabe et al., “Development of a semiconductor Compton camera,” Nucl. p. 0 Imaging performance of a Single-Plane Readout
Compton Camera∗
Om Prakash Dash, Tomislav Bokulić, Damir Bosnar,
and Mihael Makek†
University of Zagreb Faculty of Science, Department of Physics,
Zagreb, 10000, Croatia
Abstract
This work presents the design, development, and characterization of a
compact Compton camera employing a novel single-plane readout architecture. The proposed concept simplifies conventional multilayer Compton cameras by optically coupling the scatterer and absorber into a single compact detector element using a light guide, enabling readout exclusively from one side with silicon photomultipliers. 20841v1 [physics. ins-det] 3 Aug 2026Where the paper says it
Where the paper says it
[6] T. Takahashi and S. Watanabe, “Recent progress in semiconductor Compton cameras,” IEEE Trans. p. 1 Although scintillator-based systems typically exhibit slightly
lower intrinsic resolution compared to semiconductor detectors, they offer significantly higher detection efficiency, reduced cost, and simpler system integration,
making them highly suitable for imaging applications [11, 10]. Building on these advantages, scintillator-based Compton cameras have evolved
into several optimized configurations that balance efficiency, spatial resolution,
and compactness.Where the paper says it
[7] T. Tanimori et al., “MeV γ-ray imaging detector with micro-TPC,” New Astron. p. 2 By reducing the number of readout channels relative to
conventional dual-layer Compton cameras, this design offers a simpler and more
compact architecture while preserving the information necessary for Compton
image reconstruction. The detector performance is assessed through experimental measurements with 511 keV and 662 keV gamma-ray sources, providing an
evaluation of the performance and imaging capabilities of the proposed concept.Where the paper says it
[8] G. Llosá et al., “SiPMbased Compton camera for medical imaging,” Nucl. p. 2 6 ns, enabling interaction position estimation via timeof-arrival information and offering potential for intensity mapping and multisource imaging. Additionally, Barrientos developed the three-layer MACACO II
Compton camera for medical imaging, employing two continuous and one monolithic LaBr3 scintillator layers read out by pixelated SiPM arrays, achieving energy resolutions of 5.Where the paper says it
[9] R. K. Parajuli et al., “Development and applications of Compton cameras: A review,” Sensors, vol. p. 0 Imaging performance of a Single-Plane Readout
Compton Camera∗
Om Prakash Dash, Tomislav Bokulić, Damir Bosnar,
and Mihael Makek†
University of Zagreb Faculty of Science, Department of Physics,
Zagreb, 10000, Croatia
Abstract
This work presents the design, development, and characterization of a
compact Compton camera employing a novel single-plane readout architecture. The proposed concept simplifies conventional multilayer Compton cameras by optically coupling the scatterer and absorber into a single compact detector element using a light guide, enabling readout exclusively from one side with silicon photomultipliers.Where the paper says it
[10] J. P. Zhang et al., “Prototype of an array SiPM-based scintillator Compton camera,” Radiat. p. 2 More recently, hybrid scintillator configurations, such as GAGG-based Compton–
PET systems, have demonstrated the potential for multimodal imaging by combining high energy resolution with flexible and versatile detector geometries [18]. Despite these advances, conventional multi-plane Compton camera architectures remain limited by mechanical complexity, large channel counts, and
increased system thickness, which hinder portability and scalability.Where the paper says it
[11] S. Jiang et al., “A prototype of SiPM-based scintillator Compton camera with capacitive multiplexing readout,” J. p. 5 3 Experimental setup
To validate the feasibility of the proposed single-plane, single-side readout Compton camera concept, a series of preliminary laboratory measurements were performed on individual and sandwiched scintillator detector elements. These studies focused on optimizing optical coupling, reflector materials, light guide geometry, SiPM selection and readout performance prior to assembling the full
6Where the paper says it
[12] V. Schönfelder et al. p. 1 Compton cameras aim to overcome these limitations by exploiting the kinematics of Compton scattering [2]
to perform electronic collimation, enabling wider field-of-view, and improved
sensitivity. Since their first proposal by Schönfelder et al.Where the paper says it
The imaging Compton telescope (COMPTEL) on the Gamma Ray Observatory,
IEEE Transactions on Nuclear Science, vol. 31, no. 1, pp. 766–770, 1984
[13] J. Kasper et al., The SiFi-CC project—feasibility study of a scintillation-fiber-based Compton camera for proton therapy monitoring,
Physica Medica, vol. 76, pp. 317–325, 2020
[14] L. Barrientos et al. p. 2 6 ns, enabling interaction position estimation via timeof-arrival information and offering potential for intensity mapping and multisource imaging. Additionally, Barrientos developed the three-layer MACACO II
Compton camera for medical imaging, employing two continuous and one monolithic LaBr3 scintillator layers read out by pixelated SiPM arrays, achieving energy resolutions of 5.Where the paper says it
Performance evaluation of MACACO II Compton camera,
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, vol. 1014, p. 165702, 2021
[15] J. Roser et al., “Radiopharmaceutical imaging of phantoms and patients with MACACO III Compton camera,” Physica Medica, vol. p. 2 Recently, newly developed MACACO
III Compton camera, comprising three continuous LaBr3:Ce scintillator planes
coupled to SiPM arrays. The system demonstrated enhanced background rejection and successful clinical imaging of radiopharmaceuticals such as 131I and
18F-FDG, highlighting its potential for nuclear medicine applications.Where the paper says it
[16] J. Kataoka et al. p. 1 In parallel, monolithic scintillator detectors have been introduced to enhance
detection efficiency by minimizing dead space while enabling continuous position estimation through light-sharing techniques. For instance, Kataoka et al.Where the paper says it
Handy Compton camera using 3D position-sensitive scintillators coupled with large-area monolithic MPPC arrays,
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, vol. 732, pp. 403–407, 2013
[17] D. Turecek et al. p. 2 Further improvements in
three-dimensional event reconstruction have been achieved using DOI-enabled
designs, which enhance angular resolution by resolving the interaction depth
within the scintillator volume. Recent developments also explore alternative detector technologies, such as
the single-layer CdTe Compton camera with Timepix3 readout reported by
Turecek [17], featuring a 256 × 256 pixel matrix with 55 µm pitch and excellent
timing resolution of 1.Where the paper says it
Single layer Compton camera based on Timepix3 technology,
Journal of Instrumentation, vol. 15, no. 01, p. C01014, 2020
[18] K. Shimazoe et al., Development of simultaneous PET and Compton imaging using GAGG-SiPM based pixel detectors,
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, vol. 954, p. 161499, 2020
[19] O. P. Dash et al. p. 0 Imaging performance of a Single-Plane Readout
Compton Camera∗
Om Prakash Dash, Tomislav Bokulić, Damir Bosnar,
and Mihael Makek†
University of Zagreb Faculty of Science, Department of Physics,
Zagreb, 10000, Croatia
Abstract
This work presents the design, development, and characterization of a
compact Compton camera employing a novel single-plane readout architecture. The proposed concept simplifies conventional multilayer Compton cameras by optically coupling the scatterer and absorber into a single compact detector element using a light guide, enabling readout exclusively from one side with silicon photomultipliers. Imaging performance of a Single-Plane Readout
Compton Camera∗
Om Prakash Dash, Tomislav Bokulić, Damir Bosnar,
and Mihael Makek†
University of Zagreb Faculty of Science, Department of Physics,
Zagreb, 10000, Croatia
Abstract
This work presents the design, development, and characterization of a
compact Compton camera employing a novel single-plane readout architecture. The proposed concept simplifies conventional multilayer Compton cameras by optically coupling the scatterer and absorber into a single compact detector element using a light guide, enabling readout exclusively from one side with silicon photomultipliers.Where the paper says it
Where the paper says it
[20] Y. F. Du et al., “Evaluation of a Compton scattering camera using 3-D position sensitive CdZnTe detectors,” Nucl. p. 4 The angular resolution is commonly quantified using the Angular
Resolution Measure (ARM), defined as the difference between the Compton
scattering angle obtained from energy deposition and that derived from detector geometry:
ARM = θ − θg, (3)
where θ is calculated from the measured energy deposits according to Compton
kinematics (see Eq. 2), and θg is the geometrical scattering angle determined
from the known source position P0 and measured interaction positions P1 and
P2 as shown in Fig.Where the paper says it
[21] A Kishimoto, “Study of ultra-compact Compton camera based on 3-D position sensitive scintillator for environmental and medical gamma-ray imaging,” Ph.D. dissertation, Waseda Univ., Tokyo, Japan, 2016
[22] W. R. Leo, Techniques for Nuclear and Particle Physics Experiments: A How-To Approach. p. 0 1 Introduction
Gamma rays, located at the high-energy end of the electromagnetic spectrum,
possess strong penetrating power and carry unique information about radioactive sources and physics processes. Their interaction with matter enables a wide
range of imaging and spectroscopic techniques that are essential in applications
∗This work has been submitted to the IEEE Transactions on Nuclear Science for possible
publication.Where the paper says it
[23] O. P. Dash, Development and characterization of a compact singleplane readout Compton camera,
Ph.D. dissertation, Sveučilište u Zagrebu, Prirodoslovno-matematički fakultet, 2026
[24] K. Kamada et al., “Composition engineering in cerium-doped (Lu,Gd)3(Ga,Al)5O12 single-crystal scintillators,” Cryst. p. 6 Particular attention was therefore given to the choice of scintillator, reflective material, light guide, and photo-sensor to ensure efficient optical
coupling and reliable signal reconstruction. For both the scatterer and absorber elements, GAGG:Ce (Gadolinium Aluminum Gallium Garnet doped with Cerium) scintillators were employed.Where the paper says it
[25] P. Průša et al., “Light yield of (Lu,Y,Gd)3Al2Ga3O12:Ce garnets,” Radiat. p. 6 For both the scatterer and absorber elements, GAGG:Ce (Gadolinium Aluminum Gallium Garnet doped with Cerium) scintillators were employed. GAGG:Ce
offers a high light yield up to 57000 photons per 1 MeV gamma energy, high density (6.Where the paper says it
[26] A Yoshikawa et al., “Crystal growth and characterization of Ce:Gd3(Ga,Al)5O12 single crystal using floating zone method in different O2 partial pressure,” Opt. p. 8 Due to differences in number of optically transmissive and reflective
sides, the two layers exhibit slightly different light yields and energy responses. Detector characterization and imaging measurements were performed during
two measurement campaigns.Where the paper says it
[27] A Di Francesco et al., TOFPET2: a high-performance ASIC for time and amplitude measurements of SiPM signals in time-of-flight applications,
Journal of Instrumentation, vol. 11, p. C03042, Mar. 2016
[28] M. Makek et al. p. 0 Imaging performance of a Single-Plane Readout
Compton Camera∗
Om Prakash Dash, Tomislav Bokulić, Damir Bosnar,
and Mihael Makek†
University of Zagreb Faculty of Science, Department of Physics,
Zagreb, 10000, Croatia
Abstract
This work presents the design, development, and characterization of a
compact Compton camera employing a novel single-plane readout architecture. The proposed concept simplifies conventional multilayer Compton cameras by optically coupling the scatterer and absorber into a single compact detector element using a light guide, enabling readout exclusively from one side with silicon photomultipliers.Where the paper says it
Investigation of GaGG: Ce with TOFPET2 ASIC readout for applications in gamma imaging systems,
Crystals, vol. 10, no. 12, p. 1073, 2020
[29] L. A. Shepp and Y. Vardi, Imaging performance of a Single-Plane Readout
Compton Camera∗
Om Prakash Dash, Tomislav Bokulić, Damir Bosnar,
and Mihael Makek†
University of Zagreb Faculty of Science, Department of Physics,
Zagreb, 10000, Croatia
Abstract
This work presents the design, development, and characterization of a
compact Compton camera employing a novel single-plane readout architecture. The proposed concept simplifies conventional multilayer Compton cameras by optically coupling the scatterer and absorber into a single compact detector element using a light guide, enabling readout exclusively from one side with silicon photomultipliers.Maximum likelihood reconstruction for emission tomography,
IEEE Trans. Med. Imaging, vol. p. 0Where the paper says it
[30] S. J. Wilderman et al., Improved modeling of system response in list mode EM reconstruction of Compton scatter camera images,
IEEE Trans. Nucl. Sci., vol. 48, no. 1, pp. 111–116, 2001
[31] S. Agostinelli et al., GEANT4—a simulation toolkit,
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, vol. 506, no. 3, pp.
Green — the paper says it, and the page is printed. Red — no passage carries it, so treat that sentence as unverified. The same check runs on your own text: check a summary against its source, $5.
Improvements for AI systems
-
Single-plane readout architecture enables simpler and more compact architecture while preserving information necessary for Compton image reconstruction by reducing readout channels relative to conventional dual-layer Compton cameras. This allows for a system that is
simpler and more compact
compared to traditional designs, which hinders portability and scalability due to mechanical complexity. -
The use of pixelated GAGG:Ce scintillators coupled via light guides read out by a single SiPM array facilitates the development of portable gamma imaging applications suitable for rapid deployment. This configuration demonstrates the
feasibility of the proposed single-plane architecture for compact and cost-effective gamma-ray imaging applications.
-
The system can perform accurate source localization in both X and Y directions for point sources, with angular resolutions reaching 14.3 degrees–16.8 degrees for 662 keV photons and 12.4 degrees–14.3 degrees for 511 keV photons. This high fidelity reconstruction is achieved through the application of Maximum Likelihood Expectation Maximization (MLEM) algorithm on list-mode Compton camera data, confirming
accurate Compton scattering reconstruction.
-
The system can accurately distinguish between correctly reconstructed forward scattering events and background contributions by applying optimized selection criteria, such as an asymmetric cut on the total deposited energy. This refinement increases the fraction of correctly reconstructed events to about 81% while suppressing background contributions that lead to image degradation.
-
The improved analysis allows for accurate determination of interaction sequence by assigning the pixel with lower deposited energy to the first interaction in the scatterer and higher deposited energy to the second interaction in the absorber. This
enabled an unambiguous determination of the interaction sequence.
Abstract
This work presents the design, development, and characterization of a compact Compton camera employing a novel single-plane readout architecture. The proposed concept simplifies conventional multilayer Compton cameras by optically coupling the scatterer and absorber into a single compact detector element using a light guide, enabling readout exclusively from one side with silicon photomultipliers. The system was validated through Monte Carlo simulations, prototype construction, and experimental characterization using standard gamma-ray sources. Detector performance for 511 keV and 662 keV photons was optimized using simulations based on the Geant4 framework, by guiding event selection strategy. Event reconstruction relied on coincidence detection consistent with Compton scattering kinematics, while image reconstruction was performed using maximum likelihood expectation maximization algorithm. The prototype comprises 64 detector elements arranged in an 8 times8 matrix, read out by an 8 times8 silicon photomultiplier array. Each element consists of two GAGG:Ce scintillators coupled by a 20 mm long light guide. Measured energy resolutions were 8.9% plus or minus1.9% and 10.8% plus or minus1.6% for the front and back layers, respectively. Successful gamma-ray imaging was demonstrated for Na-22 and Cs-137 sources, achieving angular resolutions of 12.4 -- 14.3 at 511 keV and 14.3 -- 16.8 at 662 keV, confirming the feasibility of the proposed single-plane architecture for compact and cost-effective gamma-ray imaging applications.
Related papers
- Cryogenic Mechanical Loss of GaAs/AlGaAs Crystalline Coatings
- The physical design of the superfluid helium-4 UCN source at CSNS
- A new diffuse reflector filament for additive manufacturing of 3D printing finely-segmented plastic scintillator
- Characterization of CRYO ASIC for charge readout in the nEXO experiment
- Reconstructing High-Fidelity Light Yield Maps for Surface LArTPCs Using Crossing Cosmic Muons
- OASIS-ERIS: Open Acquisition System for IEPE Sensors - Electrically Refined and Inter-device Synchronization