Energy calibration of bulk events in the BULLKID detector
Listen
Radio episode about this paper
Transcript
Introduction to the show: ident: Physics. The day in general physics: instruments, methods and results across the field.
Kai: I'm Kai.
Mira: And I'm Mira, here with Lev.
Kai: We're looking at the paper: "Energy calibration of bulk events in the BULLKID detector".
Paper summary: Mira: Thinking about the title "Energy calibration of bulk events in the BULLKID detector" and who wrote it, we see that this work is fundamentally about making sure we can accurately measure energy when particles interact deep inside this large silicon array.
Kai: It’s important to remember that they are not just checking a simple energy scale; they are specifically looking at the performance of the bulk reconstruction method, which is key for finding those dark matter candidates or coherent neutrino-nucleus scattering signals.
Lev: For real hardware, this paper confirms that you need a calibration strategy that accounts for how the signal spreads across multiple dice, not just one isolated measurement. If you try to run this on actual hardware without these corrections, the noise and systematic errors will dominate very quickly.
Mira: So in simple terms, what they claim is that by using this method with their two hundred forty-one americium source, they’ve established a reliable way to map the energy deposits deep within the detector material <ref:2510.17423#pg2>.
Kai: It means that when we go looking for dark matter interactions, we have a more grounded understanding of what the raw signal actually represents before we start trying to extract any physics from it.
Lev: The implication is that if you want a real detector to work, you need this kind of detailed energy calibration because the hardware itself introduces these kinds of spatial dependencies that make simple scaling fail.
Mira: So the authors are showing us a path forward for making sure that when we finally look for those rare events, the measurement isn't just noisy background; it’s actually telling us something about dark matter or neutrinos.
Conclusion: Kai: So we've looked at how they calibrated their detector using that two hundred forty-one americium source, and now we're coming to the conclusion of this paper on "Energy calibration of bulk events in the BULLKID detector."
Mira: It really boils down to making sure that when you look deep inside a big block of silicon, you know what energy deposit you're actually seeing. They used a fifty-nine point five kiloelectron volt gamma ray to test this.
Lev: And what they found is that the resolution for that peak was five percent sigma, and it stayed pretty stable when they compared it to their older optical calibration method.
Kai: That stability is important because it means the physics signal you're looking for isn't being washed out by a messy energy scale. But remember, they also said the resolution gets better if you combine signals from neighboring dice.
Mira: Right, that suggests that just looking at one die deep isn't enough; you need to look at how all the dice work together to get a cleaner picture of the bulk interaction.
Lev: If we were trying to run this on actual hardware, combining signals across those dice would be a big challenge for error correction algorithms because you have all that spatial dependence.
Kai: So what does this mean for us looking at dark matter? It confirms that their setup is robust enough to handle the complexity of bulk interactions.
Mira: It gives us confidence in the data coming from this type of detector for coherent neutrino scattering searches because we know the energy measurement isn't totally unreliable.
Lev: But they also flagged a limitation—the calorimetric amplitude correction, which fixes that anti-correlation, doesn't fully account for every single effect happening at the interaction point.
Kai: So while they nailed the calibration of the bulk event itself, there’s still a layer of physical uncertainty left in how those energy losses are distributed.
Mira: Exactly. It means we have a good foundation now, but we still have to worry about how that energy loss is happening in the first place.
Lev: Next time, we need to look at the real overhead of implementing that kind of complex spatial correction on a system with thousands of detectors instead of just sixty dice.
M. Folcarellia, D. Delicato, A. Acevedo-Rentería, L. E. Ardila-Perez, L. Bandiera, M. Calvo, M. Cappelli, R.¡ Caravita, É Carillo, ○ Chowdhury, D.○ Crovo, A.○ Cruciani, A.♄ D’Addabbo, M. De Lucia, G. Del Castello, M. del Gallo Roccagiovine, É Ferraro, S. Fu, ¡ Gartmann, M. Grassi, V.üd Guidi, ○ Helis, T. Lari, L.♄ Malagutti, A. Mazzolari, É Monfardini, T. Muscheid, D. Nicolóo, F.¡ Paolucci, D.○ Pasciuto, L. Pesce, ○ Puglia, D.○ Quaranta, É M. A. Roda, S. Roddaro, M. Romagnoni, G. Signorelli, F.¡ Simon, A.¡ Tartari, ○ Vazquez-Jáuregui, M. Vignati, ○ Zao
Dipartimento di Fisica, Sapienza University of Rome · INFN Sezione di Roma · Dipartimento di Fisica Enrico Fermi, University of Pisa · INFN Sezione di Pisa · Instituto de Física, Universidad Nacional Autónoma de Mexico · INFN Sezione di Ferrara · University Grenoble Alpes, CNRS, Grenoble INP · INFN Laboratori Nazionali del Gran Sasso
physics.ins-det
Submitted: 2025-10-20
Updated: 2026-11-17
Comments: 7 pages, 5 figures Published version, Open Access under CC BY 4.0
Journal ref: Eur. Phys. J. C 86, 301 (2026)
DOI: 10.1140/epjc/s10052-026-15523-4
License: http://creativecommons.org/licenses/by/4.0/
Importance score: 79/100
The gist: BULLKID is a cryogenic, solid-state detector designed for direct searches of particle Dark Matter candidates and coherent neutrino-nucleus scattering.
Key concepts
- BULLKID
- A cryogenic, solid-state detector made of a monolithic array of silicon dice carved in crystal. It uses phonon-mediated Kinetic Inductance Detectors (KIDs) to sense interactions and is designed for direct searches of particle Dark Matter and neutrino scattering.
- 59.5 keV Gamma-ray Calibration
- The energy scale was calibrated by reconstructing a known 59.5 keV gamma-ray peak from a radioactive 241Am source. This served as the validation method, comparing the detector's measured response against an established energy standard derived from optical photon calibration.
- Bulk Event Reconstruction
- This involves studying how interactions occurring in the bulk position of Americium affect neighboring dice. By measuring amplitude ratios ($R_n$), researchers investigated anti-correlations and developed a calorimetric amplitude correction to improve resolution.
- Calorimetric Amplitude Correction
- The formula $A_{cal} = A/Q + ext{Σ } n_{ ext{neigh}}$ is used to correct for the anti-correlation observed in bulk events. This correction successfully improved the energy resolution from 5% (sigma) to 2% (sigma), indicating that simple calorimetric energy alone is insufficient.
Terminology
Summary
BULLKID is a cryogenic, solid-state detector designed for direct searches of particle Dark Matter candidates and coherent neutrino-nucleus scattering. p. 0 Moro 2, 00185 Roma, Italy
3Dipartimento di Fisica "Enrico Fermi", Università di Pisa, Largo Bruno Pontecorvo 3, 56127 Pisa, Italy
4
INFN Sezione di Pisa, Largo Bruno Pontecorvo 3, 56127 Pisa, Italy
5
Instituto de Física, Universidad Nacional Autónoma de México, A. 20-364, Ciudad de México 01000, México
6
INFN Sezione di Ferrara, Via Saragat 1, 44122 Ferrara, Italy
7University Grenoble Alpes, CNRS, Grenoble INP, Institut Néel, 38000 Grenoble, France
8
INFN Laboratori Nazionali del Gran Sasso, 67100 Assergi (AQ), Italy
9
Institute for Data Processing and Electronics, Karlsruhe Institute of Technology, Hermann-von-Helmholtz-Platz 1 76344,
Eggenstein-Leopoldshafen, Germany
10INFN - TIFPA, Via Sommarive 14, 38123 Povo (Trento), Italy
11Dipartimento di Fisica e Scienze della Terra, Università di Ferrara, Via Saragat 1, 44100 Ferrara, Italy
12Dipartimento di Neuroscienze e Riabilitazione, Università di Ferrara, Via Luigi Borsari 46, 44121 Ferrara, Italy
13Gran Sasso Science Institute, Viale Francesco Crispi, 7 Rectorate, Via Michele Iacobucci, 2, 67100 L’Aquila AQ, Italy
October 21, 2025
Abstract BULLKID is a cryogenic, solid-state detector designed for direct searches of particle Dark Matter candidates,
with mass ≲ 1 GeV/c2
, and coherent neutrino-nucleus scattering. In previous works, the array was calibrated
with bursts of optical photons, which are absorbed in the
first hundreds nanometers of the dice and give rise to surface
events. In this work, we present the reconstruction of bulk
events through the 59. In this work, we present the reconstruction of bulk
events through the 59. 5 keV 𝛾-ray generated by an 241Am
source, which emulates more closely the interaction of Dark
Matter and neutrinos.Where the paper says it
Where the paper says it
Where the paper says it
Detector Architecture and Calibration Method
BULLKID is a monolithic array of dice carved in silicon crystal and sensed by phonon-mediated cryogenic Kinetic Inductance Detectors (KIDs). The main challenge in this low-energy regime is the energy calibration, which was previously performed with bursts of 400 nm optical photons. p. 0 It is designed for the detection of sub-keV energy depositions from particle interactions within the crystal, making
it suitable for direct Dark-Matter (DM) searches [11–16] and
coherent elastic neutrino-nucleus scattering (CE𝜈NS) [17–
19] experiments. One of the main challenges in this lowenergy regime is the energy calibration, which is currently
performed with a method based on bursts of 400 nm optical
photons [9, 20]. Validating this optical calibration
method, using bulk events from particle interactions, is thus
of critical importance to confirm the detector’s performance
under realistic conditions. In this work, we present such a
validation by reconstructing the 59. In this work, we present such a
validation by reconstructing the 59. 5 keV 𝛾-ray peak from a
radioactive 241Am source using a BULLKID detector.Where the paper says it
Where the paper says it
Where the paper says it
Data Acquisition and Analysis
The experimental setup utilized a monolithic silicon wafer with 60 dice and identified 57 working KIDs due to fabrication issues. The energy of a particle interacting in a die is converted to thermal phonons, which are absorbed by the KID or by non-sensitive elements. p. 1 The energy of a particle interacting in a die is converted
to athermal phonons (Fig. 2) that, in part, are absorbed by
the KID or by non-sensitive elements, e. The strategy of the acquisition has the aim of fiducializing the
active mass, discarding all the events in which the interaction
did not take place in a main die. The incoming data stream is
triggered online, selecting all the signals with an amplitude
30 times greater than the standard deviation of the noise.Where the paper says it
Where the paper says it
Calibration Validation Findings
The results confirm the performance of the detector in view of the physics goals for dark matter search. The peak resolution is 5% (sigma) and its position is shifted by less than 10% with respect to the optical calibration. p. 0 5 keV 𝛾-ray generated by an 241Am
source, which emulates more closely the interaction of Dark
Matter and neutrinos. The peak resolution is 5% (𝜎) and
its position is shifted by less than 10% with respect to the
optical calibration. The peak resolution is 5% (𝜎) and
its position is shifted by less than 10% with respect to the
optical calibration. We observe that the resolution is further
improved by a factor 2 combining the signal from neighboring dice.Where the paper says it
Where the paper says it
Bulk Event Reconstruction
Effects related to the interaction in the bulk position of Americium can be investigated by studying the partition between main and neighboring dice. The ratio of amplitudes is defined as R n = A n / (A · Q / Q n). p. 3 4 Neighbor analysis for bulk events
Effects related to the interaction in the bulk position of
Americium can be investigated by studying the partition between main and neighboring dice. This is evaluated as the
ratio of the amplitudes of the two dice (𝐴 for the main KIDs
and 𝐴𝑛 for the neighbors), corrected for their corresponding
quality factors from Eq. The position of the subplot corresponds
to the neighbor considered; the central one shows the energy
spectrum of KID 49. For all the main KIDs, we measure
an average energy ratio of (17 ± 1)% in the vertical and
horizontal directions and (10 ± 1)% in the diagonal one. LED events, that
all happen on the surface of a die, and have an estimated light
spot size of approximately 1 mm, do not show any sign of
correlation between neighboring dice. Following the model of the phonon leakage just exposed,
the sum of the amplitudes of all the KIDs (main + neighbors) should be able to compensate for the anti-correlation,
improving the resolution of the 241Am peak.Where the paper says it
Where the paper says it
Where the paper says it
Resolution Improvement
The calorimetric amplitude Acal = A/Q + Σ n neigh. is used to correct for the anti-correlation, and this leads to an improvement of the resolution by a factor of 2, reaching the value of 2% (sigma). p. 3 An improvement of the resolution by a factor 2 is measured, reaching
the value of 2% (𝜎). 5 (right) it is represented one of
the LED acquisitions, used for the optical calibration, in the
same energy range of Americium. We evaluate a resolution
of 1% (𝜎) that is dominated by the photo-statistics of multiple photon bursts. This suggests that the calorimetric energy
does not fully correct the dependence on the interaction point
or other effects of energy loss. This suggests that the calorimetric energy
does not fully correct the dependence on the interaction point
or other effects of energy loss. Moreover, LED events are not
only localized in depth but also along the plane parallel to
the lithography.Where the paper says it
Where the paper says it
Where the paper says it
Green — the paper says it, and the page is printed. Red — no passage carries it, so treat that sentence as unverified. The same check runs on your own text: check a summary against its source, $5.
Improvements for AI systems
-
Improved energy calibration accuracy for bulk events by using a calorimetric amplitude Acal which
includes this leakage
to map to energy, resulting in a resolution improvement from 5% to 2% (sigma). -
Enhanced ability to distinguish between surface and bulk events by exploiting the anti-correlation observed in Americium events between the energy deposited in the main die and in neighboring dice, pointing to
positional effects related to the depth of the interaction point.
-
Development of a calibration function that maps calorimetric amplitude to energy, enabling
the reconstruction of the new energy spectrum of the Americium peak
with a resolution improvement by a factor 2.
Abstract
BULLKID is a cryogenic, solid-state detector designed for direct searches of particle Dark Matter candidates, with mass 1 GeV/c squared, and coherent neutrino-nucleus scattering. It is based on an array of dice carved in 5 mm thick silicon crystal, sensed by phonon-mediated Kinetic Inductance Detectors. In previous works, the array was calibrated with bursts of optical photons, which are absorbed in the first hundreds nanometers of the dice and give rise to surface events. In this work, we present the reconstruction of bulk events through the 59.5 keV γ-ray generated by an 241 Am source, which emulates more closely the interaction of Dark Matter and neutrinos. The peak resolution is 5% (σ) and its position is shifted by less than 10% with respect to the optical calibration. We observe that the resolution is further improved by a factor 2 combining the signal from neighboring dice. These results confirm the performance of the detector in view of the physics goals of the BULLKID-DM experiment for dark matter search.
Related papers
- Cryogenic Mechanical Loss of GaAs/AlGaAs Crystalline Coatings
- The physical design of the superfluid helium-4 UCN source at CSNS
- A new diffuse reflector filament for additive manufacturing of 3D printing finely-segmented plastic scintillator
- Characterization of CRYO ASIC for charge readout in the nEXO experiment
- Reconstructing High-Fidelity Light Yield Maps for Surface LArTPCs Using Crossing Cosmic Muons
- OASIS-ERIS: Open Acquisition System for IEPE Sensors - Electrically Refined and Inter-device Synchronization