Incoherent Diffraction Imaging with a Pseudo-Thermal Light Source

arXiv:2501.05417 · physics.optics · Submitted 2025-01-09 · Read on arXiv

Listen

Radio episode about this paper

Transcript

Introduction to the show: ident: Physics. The day in general physics: instruments, methods and results across the field.

Kai: We're looking at the paper: "Incoherent Diffraction Imaging with a Pseudo-Thermal Light Source".

Mira: Here's the gist of the paper. Incoherent Diffraction Imaging (IDI) is a diffraction-based imaging technique that exploits second-order spatial correlations of partially coherent light to retrieve structural information from scattering centers The paper proposes an alternative experimental set-up based on a table-top Pseudo-Thermal Light Source (PTLS) to explore IDI under a wide range of physically relevant conditions and benchmark numerical models IDI is named in analogy to Coherent Diffraction Imaging (CDI), highlighting its reliance on a comparatively lower degree of coherence This technique requires the recording of the diffracted light within a timescale shorter or comparable to the coherence time, tauc, of the light field The autocorrelation of the recorded intensity is insensitive to these spatial variations and will thus progressively build-up when averaging over multiple acquisitions A key application of IDI is to retrieve the structural information of an object via incoherent scattering processes, namely fluorescence Fluorescence is typically considered as incoherent light due to the quantum (random) nature of its emission Experimental Set-up and PTLS Characterization The Pseudo-Thermal Light Source (PTLS) is constructed using a ground-glass diffuser illuminated by a CW diode laser of 660 nm to control spatial coherence via the illumination area The second-order temporal coherence can be controlled by the rotation speed of the diffuser, which is inversely proportional to the illumination area The brightness of this PTLS, namely the number of photons per pixel per frame mu, can be controlled via laser power and additional filtering The temporal gating of the incoherent light is carried out via the exposure time of the detector Measuring Structural Information Second-order spatial correlations are used to extract structural information of the scatterers distribution given a finite degree of coherence of a PTLS The normalized g(2) (®q) maps are shown on Fig.

Kai: 2(d,e,f), where the diffraction patterns associated with each object intensity distribution are clearly visible in these second order spatial correlations Numerical simulations of the computed g(2)(®q) maps reproduce well the experimental features The object intensity distributions shown in Fig.

Mira: 2(a,b) were mostly intended to reproduce what was done in the first IDI experiment

16: and the first high-order correlation imaging experiment

19: Assessing Imaging Capabilities The versatility of this PTLS optical set-up allows for benchmarking analytical and numerical models of IDI The study assesses the scalings of the visibility for different source brightness (mu) and number of temporal modes accumulated in each frame An optimal SBR of ≈ 0.7 is found for a large enough brightness (mu ≳ 0.1) and for M ∼ 1 The overall trends observed both in simulations and experimental data are in good agreement with this scaling, both with respect to μ and M This table-top set-up enables the experimental exploration of IDI over an unprecedented range of physically relevant parameters The measured visibility and trends are found to be in reasonably good agreement with existing numerical and analytical methods used to model IDI experiments This set-up can experimentally benchmark the IDI methodology and thus efficiently address the potential of IDI to realize nanometer scale diffraction-based imaging using partially coherent light sources References J.

Kai: Miao, P.

Paper summary: Kai: To recap, this paper introduces Incoherent Diffraction Imaging with a Pseudo-Thermal Light Source, or PTLS, as a way to test IDI with conditions that are physically relevant. They are exploring how second order spatial correlations can retrieve structure from scattering centers using partially coherent light.

Mira: The core thesis is that by using a table-top setup like the PTLS, they can experimentally probe IDI and compare their measurements against analytical and numerical models of this technique.

Lev: The paper describes building this PTLS with a ground-glass diffuser and a laser to control the coherence time via rotation speed, which is inversely proportional to the illumination area.

Kai: They also show how they measure structural information using normalized g sub two maps, which clearly show the diffraction patterns of different object intensity distributions in these correlations <ref:2501.05417#pg1>.

Mira: The authors then focus on assessing how the imaging capabilities scale with source brightness mu and the number of temporal modes accumulated in each frame.

Lev: They found that an optimal signal to background ratio is around zero point seven for a brightness mu greater than zero point one and M equal to one, which matches what they see in their simulations.

Kai: This gives us concrete data on how the imaging performance behaves with respect to the source brightness and the number of temporal modes involved.

Mira: It also points out that these long acquisition times, around five hours for this experiment, are a consequence of low detected photons per pixel per frame mu equal to seven point seven times ten to minus three and a rather long FEL pulse duration of six point two femtoseconds compared to the coherence time of four point zero femtoseconds.

Lev: That comparison between the pulse duration and the coherence time resulted in a beta value of zero point eighteen, which is important for understanding how things scale.

Kai: So they are using this setup not just to get a picture, but to rigorously test the limits of IDI for physically relevant parameters like coherence time and source brightness.

Mira: The paper also points out that long acquisition times mean imaging more complex objects has been difficult so far because of the demand for XFEL access.

Lev: They explicitly state that rigorous tests are needed for IDI performance at these physical parameters to fully understand the technique.

Conclusion: Kai: So, looking at this paper "Incoherent Diffraction Imaging with a Pseudo-Thermal Light Source", the authors have built a table-top setup to experimentally explore IDI across physically relevant conditions.

Mira: They found that their measured visibility and trends align reasonably well with existing numerical and analytical methods used to model IDI experiments.

Lev: This experimental benchmark shows the potential for using this set-up to test IDI methodology and address the potential of it for nanometer scale diffraction-based imaging using partially coherent light sources.

Kai: In simple terms, they’ve shown that their table-top setup can give us good data that supports the theoretical models they use for IDI.

Mira: The implication is that this technique might be a viable path toward achieving nanometer scale imaging by using these kinds of partially coherent light sources in the future.

Lev: It confirms that testing IDI with source brightness and coherence time is a necessary step before we can really expect it to perform on more complex objects.

Kai: So, this work provides a tangible experimental platform for understanding how IDI works in practice right now.

PABLO SAN MIGUEL CLAVERIA, –SEBASTIÃOŗ⺔NTE ANTUNES, –PEER BIESTERFELD, –MATILDE FERNANDES, –MATILDE GARCIA, –MATILDE NUNES, –LUCAS ANSIA FERNANDEZ, –GARETH O. WILLIAMS, –SVEN FROEHLICH, –DAVID THEIDEL, –PHILIP MOSEL, IHSAN FSAIFES, ANDREA TRABATTONI, MARCO PICCARDO, –JEAN-CHRISTOPHE CHANTELOUP, –MILUTIN KOVACEV, –HAMED MERDJI, AND MARTA FAJARDO

GoLP/Instituto de Plasmas e Fusóo Nuclear, Instituto Superior Técnico, Universidade de Lisboa · Institut für Quantenoptik, Leibniz University Hannover · Laboratoire d’Optique Appliquພ, ENSTA Paris, CNRS, Ecole Polytechnique, Institut Polytechnique de Paris · LULI, CNRS, Ecole Polytechnique, CEA

physics.optics

Submitted: 2025-01-09

Updated: 2025-01-09

DOI: 10.1088/1367-2630/aeb3a4

License: http://creativecommons.org/licenses/by/4.0/

Importance score: 78/100

The gist: Incoherent Diffraction Imaging (IDI) is a diffraction-based imaging technique that exploits second-order spatial correlations of partially coherent light to retrieve structural information from…

Key concepts

Incoherent Diffraction Imaging (IDI)
A technique that uses the second-order spatial correlations of partially coherent light to reconstruct structural information from scattering centers. It relies on recording diffracted light within a specific timescale relative to the light's coherence time, often applied to incoherent sources like fluorescence.
Pseudo-Thermal Light Source (PTLS)
A table-top optical setup built with a ground-glass diffuser illuminated by a 660 nm diode laser. This source allows control over spatial coherence by adjusting the illumination area and temporal coherence via diffuser rotation speed, enabling exploration of different physical conditions.
Second-order Spatial Correlations (g(2)(q) maps)
These are measurements used to extract structural data about the distribution of scatterers. The normalized g(2)(q) maps show diffraction patterns associated with object intensity distributions, which are then compared against numerical simulations to validate the imaging process.

Terminology

Summary

Incoherent Diffraction Imaging (IDI) is a diffraction-based imaging technique that exploits second-order spatial correlations of partially coherent light to retrieve structural information from scattering centers The paper proposes an alternative experimental set-up based on a table-top Pseudo-Thermal Light Source (PTLS) to explore IDI under a wide range of physically relevant conditions and benchmark numerical models

Introduction to IDI

IDI is named in analogy to Coherent Diffraction Imaging (CDI), highlighting its reliance on a comparatively lower degree of coherence This technique requires the recording of the diffracted light within a timescale shorter or comparable to the coherence time, tauc, of the light field The autocorrelation of the recorded intensity is insensitive to these spatial variations and will thus progressively build-up when averaging over multiple acquisitions A key application of IDI is to retrieve the structural information of an object via incoherent scattering processes, namely fluorescence Fluorescence is typically considered as incoherent light due to the quantum (random) nature of its emission

Experimental Set-up and PTLS Characterization

The Pseudo-Thermal Light Source (PTLS) is constructed using a ground-glass diffuser illuminated by a CW diode laser of 660 nm to control spatial coherence via the illumination area The second-order temporal coherence can be controlled by the rotation speed of the diffuser, which is inversely proportional to the illumination area The brightness of this PTLS, namely the number of photons per pixel per frame mu, can be controlled via laser power and additional filtering The temporal gating of the incoherent light is carried out via the exposure time of the detector

Measuring Structural Information

Second-order spatial correlations are used to extract structural information of the scatterers distribution given a finite degree of coherence of a PTLS The normalized g(2) (®q) maps are shown on Fig. 2(d,e,f), where the diffraction patterns associated with each object intensity distribution are clearly visible in these second order spatial correlations Numerical simulations of the computed g(2)(®q) maps reproduce well the experimental features The object intensity distributions shown in Fig. p. 5

Where the paper says it

of the intensity auto-correlations we roll each frame on itself in order to have a same number of realisations for each 𝑞 [12]. The diffraction patterns associated to each object intensity distribution are clearly visible in these second order spatial correlations, despite the varying level of visibility.

2(a,b) were mostly intended to reproduce what was done in the first IDI experiment [16] and the first high-order correlation imaging experiment [19]

Assessing Imaging Capabilities

The versatility of this PTLS optical set-up allows for benchmarking analytical and numerical models of IDI The study assesses the scalings of the visibility for different source brightness (mu) and number of temporal modes accumulated in each frame An optimal SBR of ≈ 0.7 is found for a large enough brightness (mu ≳ 0. p. 6

Where the paper says it

Using 100 frames for the calculation of each 𝑔 (2) ( ®𝑞), we found an optimal SBR of ≈ 0. 7 for a large enough brightness (𝜇 ≳ 0.

1) and for M ∼ 1 The overall trends observed both in simulations and experimental data are in good agreement with this scaling, both with respect to μ and M

Conclusion of the Study

This table-top set-up enables the experimental exploration of IDI over an unprecedented range of physically relevant parameters The measured visibility and trends are found to be in reasonably good agreement with existing numerical and analytical methods used to model IDI experiments This set-up can experimentally benchmark the IDI methodology and thus efficiently address the potential of IDI to realize nanometer scale diffraction-based imaging using partially coherent light sources

References

J. Miao, P. Charalambous, J. p. 7

Where the paper says it

References 1. Charalambous, J.

Kirz, and D. p. 7
Where the paper says it

Charalambous, J. Kirz, and D.

Sayre, “Extending the methodology of x-ray crystallography to allow imaging of micrometre-sized non-crystalline specimens,” Nature 400, 342–344 (1999)

H. N. Chapman, A. p. 7

Where the paper says it

Sayre, “Extending the methodology of x-ray crystallography to allow imaging of micrometre-sized non-crystalline specimens,” Nature 400, 342–344 (1999). Chapman, A.

Barty, M. J. Bogan, et al. p. 7
Where the paper says it

Chapman, A. Bogan, et al.

, “Femtosecond diffractive imaging with a soft-x-ray free-electron laser,” Nat. p. 7
Where the paper says it

Bogan, et al. , “Femtosecond diffractive imaging with a soft-x-ray free-electron laser,” Nat.

Phys. 2, 839–843 (2006)

A. Ravasio, D. p. 7

Where the paper says it

2, 839–843 (2006). Ravasio, D.

Gauthier, F. p. 7
Where the paper says it

Ravasio, D. Gauthier, F.

R. N. C. Maia, et al. p. 7
Where the paper says it

Gauthier, F. Maia, et al.

, “Single-shot diffractive imaging with a table-top femtosecond soft x-ray laser-harmonics source,” Phys. p. 7
Where the paper says it

Maia, et al. , “Single-shot diffractive imaging with a table-top femtosecond soft x-ray laser-harmonics source,” Phys.

Rev. Lett. 103, 028104 (2009)

R. Neutze, R. Wouts, D. van der Spoel, et al. p. 7

Where the paper says it

103, 028104 (2009). van der Spoel, et al.

, “Potential for biomolecular imaging with femtosecond x-ray pulses,” Nature 406, 752–757 (2000)

I. K. Robinson, I. p. 7

Where the paper says it

, “Potential for biomolecular imaging with femtosecond x-ray pulses,” Nature 406, 752–757 (2000). Robinson, I.

A. Vartanyants, G. p. 7
Where the paper says it

Robinson, I. Vartanyants, G.

J. Williams, et al. p. 7
Where the paper says it

Vartanyants, G. Williams, et al.

, “Reconstruction of the shapes of gold nanocrystals using coherent x-ray diffraction,” Phys. p. 7
Where the paper says it

Williams, et al. , “Reconstruction of the shapes of gold nanocrystals using coherent x-ray diffraction,” Phys.

Rev. Lett. 87, 195505 (2001)

J. Duarte, R. Cassin, J. Huijts, et al. p. 7

Where the paper says it

87, 195505 (2001). Huijts, et al.

, “Computed stereo lensless x-ray imaging,” Nat. p. 7
Where the paper says it

Huijts, et al. , “Computed stereo lensless x-ray imaging,” Nat.

Photonics 13, 449–453 (2019)

A. Munke, J. Andreasson, A. p. 7

Where the paper says it

Photonics 13, 449–453 (2019). Andreasson, A.

Aquila, et al. p. 7
Where the paper says it

Andreasson, A. Aquila, et al.

, “Coherent diffraction of single rice dwarf virus particles using hard x-rays at the linac coherent light source,” Sci. p. 7
Where the paper says it

Aquila, et al. , “Coherent diffraction of single rice dwarf virus particles using hard x-rays at the linac coherent light source,” Sci.

Data 3, 160064 (2016)

P. J. Ho, C. Knight, and L. p. 8

Where the paper says it

119, 053401 (2017). Knight, and L.

Young, “Fluorescence intensity correlation imaging with high spatial resolution and elemental contrast using intense x-ray pulses,” Struct. p. 8
Where the paper says it

Knight, and L. Young, “Fluorescence intensity correlation imaging with high spatial resolution and elemental contrast using intense x-ray pulses,” Struct.

Dyn. 8, 044101 (2021)

H. E. White et al. p. 6

Where the paper says it

(b) Measured SBR (see text for details) for different 𝜇 and M (𝑁M). The actual measurements were performed at the white crosses, and the colormap shows interpolated results.

, Introduction to Atomic Spectra (McGraw-Hill Book Co. p. 8
Where the paper says it

White et al. , Introduction to Atomic Spectra (McGraw-Hill Book Co.

, Inc., 1934)

F. Trost, K. Ayyer, and H. p. 8

Where the paper says it

, Introduction to Atomic Spectra (McGraw-Hill Book Co. Ayyer, and H.

N. Chapman, “Photon statistics and signal to noise ratio for incoherent diffraction imaging,” New J. p. 8
Where the paper says it

Ayyer, and H. Chapman, “Photon statistics and signal to noise ratio for incoherent diffraction imaging,” New J.

Phys. 22, 083070 (2020)

N. Nakamura, S. p. 8

Where the paper says it

Goodman, Statistical Optics (Wiley, 1985). Nakamura, S.

Matsuyama, T. p. 8
Where the paper says it

Nakamura, S. Matsuyama, T.

Inoue, et al. p. 8
Where the paper says it

Matsuyama, T. Inoue, et al.

, “Focus characterization of an X-ray free-electron laser by intensity correlation measurement of X-ray fluorescence,” J. p. 8
Where the paper says it

Inoue, et al. , “Focus characterization of an X-ray free-electron laser by intensity correlation measurement of X-ray fluorescence,” J.

Synchrotron Radiat. p. 8
Where the paper says it

, “Focus characterization of an X-ray free-electron laser by intensity correlation measurement of X-ray fluorescence,” J. Synchrotron Radiat.

p. 8
Where the paper says it

, “Focus characterization of an X-ray free-electron laser by intensity correlation measurement of X-ray fluorescence,” J. Synchrotron Radiat.

p. 8
Where the paper says it

, “Focus characterization of an X-ray free-electron laser by intensity correlation measurement of X-ray fluorescence,” J. Synchrotron Radiat.

p. 8
Where the paper says it

, “Focus characterization of an X-ray free-electron laser by intensity correlation measurement of X-ray fluorescence,” J. Synchrotron Radiat.

27, 1366–1371 (2020)

I. Inoue, K. Tamasaku, T. p. 8

Where the paper says it

27, 1366–1371 (2020). Tamasaku, T.

Osaka, et al. p. 8
Where the paper says it

Tamasaku, T. Osaka, et al.

, “Determination of X-ray pulse duration via intensity correlation measurements of X-ray fluorescence,” J. p. 8
Where the paper says it

Osaka, et al. , “Determination of X-ray pulse duration via intensity correlation measurements of X-ray fluorescence,” J.

Synchrotron Radiat. 26, 2050–2054 (2019)

F. Trost, K. Ayyer, M. Prasciolu, et al. p. 8

Where the paper says it

26, 2050–2054 (2019). Prasciolu, et al.

, “Imaging via correlation of x-ray fluorescence photons,” Phys. p. 8
Where the paper says it

Prasciolu, et al. , “Imaging via correlation of x-ray fluorescence photons,” Phys.

Rev. Lett. 130, 173201 (2023)

A. Madsen, J. Hallmann, G. p. 8

Where the paper says it

130, 173201 (2023). Hallmann, G.

Ansaldi, et al. p. 8
Where the paper says it

Hallmann, G. Ansaldi, et al.

, “Materials Imaging and Dynamics (MID) instrument at the European X-ray Free-Electron Laser Facility,” J. p. 8
Where the paper says it

Ansaldi, et al. , “Materials Imaging and Dynamics (MID) instrument at the European X-ray Free-Electron Laser Facility,” J.

Synchrotron Radiat. 28, 637–649 (2021)

O. Katz, P. Heidmann, M. p. 8

Where the paper says it

28, 637–649 (2021). Heidmann, M.

Fink, and S. p. 8
Where the paper says it

Heidmann, M. Fink, and S.

Gigan, “Non-invasive single-shot imaging through scattering layers and around corners via speckle correlations,” Nat. p. 8
Where the paper says it

Fink, and S. Gigan, “Non-invasive single-shot imaging through scattering layers and around corners via speckle correlations,” Nat.

Photonics 8, 784–790 (2014)

R. Schneider, T. p. 8

Where the paper says it

Photonics 8, 784–790 (2014). Schneider, T.

Mehringer, G. p. 8
Where the paper says it

Schneider, T. Mehringer, G.

Mercurio, et al. p. 8
Where the paper says it

Mehringer, G. Mercurio, et al.

, “Quantum imaging with incoherently scattered light from a free-electron laser,” Nat. p. 8
Where the paper says it

Mercurio, et al. , “Quantum imaging with incoherently scattered light from a free-electron laser,” Nat.

Phys. 14, 126–129 (2018)

T. Lu, Y. Liu, H. Lin, et al. p. 8

Where the paper says it

14, 126–129 (2018). Lin, et al.

, “Non-invasive imaging through dynamic scattering layers via speckle correlations,” Opt. p. 8
Where the paper says it

Lin, et al. , “Non-invasive imaging through dynamic scattering layers via speckle correlations,” Opt.

Rev. 28, 557–563 (2021)

L. E. Estes, L. M. Narducci, and R. p. 8

Where the paper says it

28, 557–563 (2021). Narducci, and R.

A. Tuft, “Scattering of light from a rotating ground glass∗,” J. p. 8
Where the paper says it

Narducci, and R. Tuft, “Scattering of light from a rotating ground glass∗,” J.

Opt. Soc. Am 61, 1301–1306 (1971)

V. S. Starovoitov, V. p. 8

Where the paper says it

61, 1301–1306 (1971). Starovoitov, V.

N. Chizhevsky, D. p. 8
Where the paper says it

Starovoitov, V. Chizhevsky, D.

B. Horoshko, and S. p. 8
Where the paper says it

Chizhevsky, D. Horoshko, and S.

Y. Kilin, “Spatio-temporal correlations of photons from a pseudo-thermal source,” J. p. 8
Where the paper says it

Horoshko, and S. Kilin, “Spatio-temporal correlations of photons from a pseudo-thermal source,” J.

Appl Spectrosc 90, 377–387 (2023)

F. Trost, K. Ayyer, D. Oberthuer, et al. p. 8

Where the paper says it

90, 377–387 (2023). Oberthuer, et al.

, “Speckle contrast of interfering fluorescence X-rays,” J. p. 8
Where the paper says it

Oberthuer, et al. , “Speckle contrast of interfering fluorescence X-rays,” J.

Synchrotron Radiat. 30, 11–23 (2023)

C. Rosales-Guzmán and A. p. 8

Where the paper says it

30, 11–23 (2023). Rosales-Guzmán and A.

Forbes, How to Shape Light with Spatial Light Modulators (2017)

“Zenodo repository for data and codes,” T.B.D. (2024)

I(theta) ∝ cos2(pi/λ sin θ) × sin2(pi/r sinc θ), d ≈ 1 mm is the distance between the two Gaussian light sources, r ≈ 100 μm is the root-mean-square size of each Gaussian light source and θ is the observation angle.

Green — the paper says it, and the page is printed. Red — no passage carries it, so treat that sentence as unverified. The same check runs on your own text: check a summary against its source, $5.

Improvements for AI systems

  1. Scaled Experiment Validation for IDI

The table-top experimental set-up based on a Pseudo-Thermal Light Source allows for benchmarking numerical and analytical models of Incoherent Diffraction Imaging (IDI) under physically relevant conditions, exploring the scalings of the Signal-to-Background Ratio and Signal-to-Noise Ratio for different source brightness and temporal modes.

  1. Coherence Parameter Extraction

The system can experimentally determine the degree of coherence by measuring the second order temporal correlation function g(2)(tau) = / squared, which is shown to be proportional to the rotation speed of the diffuser.

  1. Visibility and Noise Benchmarking

The system can quantify visibility and noise under various conditions by fitting the maps to G(2) = B + Sg(1)(q)2, allowing for a comparison of experimental Signal-to-Background Ratio (SBR) and Signal-to-Noise Ratio (SNR) against simulation results.

  1. Parameter Sensitivity Analysis

The system can assess how the visibility decreases as the number of temporal modes M increases, providing quantitative measurements of SNR and SBR for different average number of photons per pixel per frame mu and accumulated temporal modes M, comparing experimental data with theoretical scaling laws like SNRCrystal proportional to mu squared M(1/2).

  1. Simulation Validation Framework

The inclusion of a simulation tool that accounts for the degree of temporal coherence allows researchers to quickly check the feasibility of their imaging conditions by generating synthetic frames based on object intensity distributions and Poisson statistics.

Abstract

Incoherent Diffraction Imaging - IDI - is a diffraction-based imaging technique that has been recently proposed to exploit the partial coherence of incoherently scattered light to retrieve structural information from the scattering centers. Similar to the stellar intensity interferometry of Hanbury Brown and Twiss, the signal builds up on the second-order spatial correlations of the emitted light. The complex spatial distribution of the target is thereby encoded in the spatial intensity fluctuations of the scattered light. The first experimental realisations of this imaging technique have been realised using the fluorescence excited by an ultra-short X-ray pulse at Free Electron Laser (FEL) facilities. Here, we propose an alternative set-up based on a table-top Pseudo-Thermal Light Source. This set-up allows us to explore IDI under a wide range of physically relevant conditions as well as to benchmark numerical and analytical models currently used to determine the imaging capabilities of this technique.

Related papers