First application of the optimised next neighbour cleaning to data from imaging atmospheric Cherenkov telescopes

arXiv:2611.05123 · astro-ph.IM · Submitted 2026-11-03 · Read on arXiv

Listen

Radio episode about this paper

Transcript

Introduction to the show: ident: Astrophysics. The day in astrophysics: observations, models and what the data forces.

Vera: We're looking at the paper: "First application of the optimised next neighbour cleaning to data from imaging atmospheric Cherenkov telescopes".

Jocelyn: Here's the gist of the paper. Imaging atmospheric Cherenkov telescopes (IACTs) cameras are constantly subject to signals from the night sky background and electronic noise during event recordings.

Vera: In this paper, we present the implementation of the optimised next neighbour (ONN) technique to the Very Energetic Radiation Imaging Telescope Array System (VERITAS) reconstruction pipeline.

Jocelyn: With this method, cleaning thresholds are derived in a two-parameter space, composed of the minimum total integrated charge of a cluster of pixels, qmin, and by the maximum difference in the pulse arrival time within the cluster, δt.

Vera: The cleaning contours in qmin − δt are adjusted to set a high probability of noise suppression while optimising the retention of pixels containing Cherenkov light.

Paper summary: Vera: So this paper is about a new image cleaning technique called the optimised next neighbour or ONN for the VERITAS reconstruction pipeline. It tackles the problem of keeping good Cherenkov light signals while getting rid of that constant noise from the night sky background and electronic noise during event recordings.

Jocelyn: Exactly, Vera. The main idea is to derive cleaning thresholds in a two-parameter space defined by something called qmin, which is the minimum total integrated charge of a cluster of pixels, and delta t max, which is the maximum difference in pulse arrival time within that same cluster.

Subrahmanyan: That sounds like you're looking at how to dynamically set the cuts based on local pixel properties and timing differences rather than using fixed thresholds. How does this approach actually balance keeping good signal pixels with suppressing noise?

Vera: Well, they found that by adjusting the cleaning contours in the qmin versus delta t max space, they can set a high probability of noise suppression while still optimizing how many pixels containing Cherenkov light they keep. They found a maximum probability of noise cluster retention called facc equal to five times ten to the negative four provides that sweet spot.

Jocelyn: So that specific value, facc equals five times ten to the negative four, is what they used as the optimal balance between suppressing noise, keeping Cherenkov signals, and preserving those image shapes. That sounds like a very specific tuning process for their cleaning algorithm.

Subrahmanyan: I see. It’s about finding that precise parameter setting where you get the best trade-off across all three goals: noise suppression, signal retention, and image morphology preservation. What were the initial benchmarks they used to determine this facc value?

Vera: They looked at Monte Carlo simulations of gamma ray events and cleaned them assuming different values for facc to see what happened. They found that when they use this method, compared to the VERITAS double-pass cleaning method, they see an increase in effective areas at the lower energy range, specifically around sixty to ninety giga-electron volts by a factor of up to twenty five.

Jocelyn: That's a significant gain in sensitivity for that lower energy band. And they also managed to reduce the energy thresholds by up to twenty two percent with this ONN method. That sounds like it helps them see fainter things better at the low end of their spectrum.

Subrahmanyan: Reducing the energy threshold by twenty two percent is a substantial improvement when you're trying to reconstruct spectra, which is what we really care about in cosmology. What did they find when they tested this method on real data from the Crab Nebula?

Vera: They tested it on Crab Nebula data and found that there was an increased number of reconstructed excess events at energies below one tera electron volt by a factor of up to eighty two. That's quite a jump in the event counts for those lower energy ranges.

Paper summary: Jocelyn: Eighty two times more events below one tera electron volt is impressive, especially when you consider the overall sensitivity improvement they reported later, which was about eight times higher differential sensitivity around twenty giga-electron volts.

Subrahmanyan: So we're talking about a factor of eight increase in differential sensitivity at twenty giga-electron volts. That points toward better resolution in that specific energy regime, which is important for probing structure formation models. What’s the big picture here for us?

Vera: This method seems especially advantageous for faint and transient signals because it allows them to use that lower energy threshold more effectively when reconstructing energy spectra. It should be suitable for any IACT data, including CTAO, MAGIC, and HESS, as long as they have arrival timing of extensive air showers available in the nanosecond range.

Jocelyn: So the paper "First application of the optimised next neighbour cleaning to data from imaging atmospheric Cherenkov telescopes" suggests that this ONN technique offers a way to clean data that is more tailored to the local noise environment and signal characteristics. It’s not just another fixed filter, but something dynamic based on how close pixels are and how long their light pulses arrive.

Subrahmanyan: I think the real implication is how much cleaner we can get our fundamental measurements from these instruments, allowing us to probe fainter sources or lower energy phenomena more reliably. If this works as well across different telescopes like CTAO, it sets a new standard for data processing pipelines in this field.

Vera: Right. So they’ve shown that by using this ONN procedure, they can get better effective areas at low energies and improve the energy resolution below one tera electron volt by about fifteen percent for their specific configuration. That directly relates to reducing the energy bias when you're looking at those sub-hundred giga-electron volt events.

Jocelyn: So what this means for pulsar timing observations is that if we can clean our Cherenkov images this well, we might be able to detect fainter signals or see features in the light curve that are currently lost in the noise floor because of poor image quality.

Subrahmanyan: We need to keep an eye on whether this method scales as well when you move from VERITAS data to other array systems. The success of this ONN technique hinges on that timing information being available with good resolution, which is a key limitation they mention for its general applicability.

Vera: That's the caveat they flag: it depends entirely on having that arrival timing of extensive air showers available at a reasonable nanosecond resolution, otherwise the method’s power is limited. That’s the practical constraint we have to keep in mind.

Jocelyn: So we see a method that boosts event retention significantly in real data like Crab Nebula, gives us better energy thresholds, and improves sensitivity across the board while being flexible enough for different instruments. It seems like a solid step forward for how we clean these Cherenkov images.

Conclusion: Vera: So to wrap up this paper, we're looking at how they put their new optimised next neighbour cleaning technique onto real data from VERITAS.

Jocelyn: It was all about taking a complex noise problem and finding a way to clean the image better than before.

Subrahmanyan: The core of it is using these two parameters, qmin for minimum charge and delta t max for the maximum arrival time difference within a pixel cluster.

Vera: Exactly. They found that by adjusting those boundaries in this parameter space, you can set a cleaning probability called facc equal to five times ten to the negative four.

Jocelyn: That specific tuning allows them to balance suppressing noise against keeping the actual Cherenkov light signals intact while preserving the shape of the image.

Subrahmanyan: And they showed that this method improves things in real data, like on Crab Nebula, by increasing counts below one tera electron volt by a factor of eighty two.

Vera: It also boosts the differential sensitivity around twenty giga electron volts by a factor of eight. That means better resolution at those lower energies.

Jocelyn: This whole thing seems really useful for faint or transient signals because it lets you use that lower energy threshold more effectively when you're trying to reconstruct an energy spectrum.

Subrahmanyan: It should be applicable across different IACT instruments like CTAO and HESS, as long as we have that nanosecond timing information available for the air showers.

Vera: The authors pointed out a major caveat though: this method really depends on having that good arrival timing resolution in the nanosecond range.

Jocelyn: So, they've shown a way to clean data more intelligently based on local noise and signal characteristics, offering real gains in sensitivity and energy resolution.

Subrahmanyan: That kind of tailored cleaning procedure is what we need when trying to push our limits on probing the structure formation of the universe.

M. Kherlakian, G. Maier

Deutsches Elektronen-Synchrotron DESY · Humboldt-University zu Berlin · Ruhr-University Bochum Astronomisches Institut

astro-ph.IM

Submitted: 2026-11-03

Updated: 2026-11-03

Comments: Accepted for publication by A&A

DOI: 10.1051/0004-6361/202659160

Code: https://github.com/nepomukotte/CARE

License: http://creativecommons.org/licenses/by/4.0/

Importance score: 81/100

The gist: Imaging atmospheric Cherenkov telescopes (IACTs) cameras are constantly subject to signals from the night sky background and electronic noise during event recordings.

Key concepts

Optimised Next Neighbour (ONN) Technique
This method cleans noisy image data by dynamically setting selection cuts based on the minimum pixel charge ($q_{min}$) and the maximum arrival-time difference ($\delta t$) within a cluster of neighboring pixels. It filters out noise clusters by ensuring their properties fall below a threshold probability ($f_{acc}$), balancing noise suppression with signal retention.
Cleaning Thresholds ($q_{min}$, $\delta t$)
The cleaning process is defined by two parameters: $q_{min}$, the minimum total integrated charge required for a pixel cluster, and $\delta t$, the maximum allowed difference in pulse arrival time within that cluster. These parameters are tuned to maximize noise suppression while preserving pixels containing actual Cherenkov light signals.
Effective Area Improvement
The ONN method substantially increases the effective area of the telescope, particularly in the lower energy range (60-90 GeV). This gain is achieved by better retaining faint Cherenkov signals and reducing energy thresholds, allowing for more accurate reconstruction of gamma-ray spectra compared to standard cleaning methods.

Terminology

Summary

Imaging atmospheric Cherenkov telescopes (IACTs) cameras are constantly subject to signals from the night sky background and electronic noise during event recordings. p. 0

Where the paper says it

ruhr-uni-bochum. de November 4, 2026 ABSTRACT Imaging atmospheric Cherenkov telescopes (IACTs) cameras are constantly subject to signals from the night sky background and electronic noise during event recordings.

In this paper, we present the implementation of the optimised next neighbour (ONN) technique to the Very Energetic Radiation Imaging Telescope Array System (VERITAS) reconstruction pipeline. p. 0
Where the paper says it

Image cleaning methods are typically employed to eliminate pixels that are mostly noisecontaminated and lack sufficient Cherenkov light. In this paper, we present the implementation of the optimised next neighbour (ONN) technique to the Very Energetic Radiation Imaging Telescope Array System (VERITAS) reconstruction pipeline.

With this method, cleaning thresholds are derived in a two-parameter space, composed of the minimum total integrated charge of a cluster of pixels, qmin, and by the maximum difference in the pulse arrival time within the cluster, δt. p. 0
Where the paper says it

In this paper, we present the implementation of the optimised next neighbour (ONN) technique to the Very Energetic Radiation Imaging Telescope Array System (VERITAS) reconstruction pipeline. With this method, cleaning thresholds are derived in a two-parameter space, composed of the minimum total integrated charge of a cluster of pixels, qmin, and by the maximum difference in the pulse arrival time within the cluster, δt .

The cleaning contours in qmin − δt are adjusted to set a high probability of noise suppression while optimising the retention of pixels containing Cherenkov light. p. 0
Where the paper says it

With this method, cleaning thresholds are derived in a two-parameter space, composed of the minimum total integrated charge of a cluster of pixels, qmin, and by the maximum difference in the pulse arrival time within the cluster, δt . The cleaning contours in qmin − δt are adjusted to set a high probability of noise suppression while optimising the retention of pixels containing Cherenkov light.

A maximum probability of noise cluster retention of facc = 5×10−4 was found to provide the optimal balance between noise suppression, retention of Cherenkov signals, and preservation of image morphologies. p. 0
Where the paper says it

In this paper, we investigate the impact of different levels of image noise contamination on the reconstruction efficiency. A maximum probability of noise cluster retention of facc = 5×10−4 was found to provide the optimal balance between noise suppression, retention of Cherenkov signals, and preservation of image morphologies.

In comparison to the VERITAS double-pass image cleaning method, effective areas are increased at the lower energy range (∼ 60 - 90 GeV) by a factor of up to ∼ 25. p. 0
Where the paper says it

A maximum probability of noise cluster retention of facc = 5×10−4 was found to provide the optimal balance between noise suppression, retention of Cherenkov signals, and preservation of image morphologies. In comparison to the VERITAS double-pass image cleaning method, effective areas are increased at the lower energy range (∼ 60 - 90 GeV) by a factor of up to ∼ 25.

Energy thresholds are reduced by up to ∼ 22%. p. 0
Where the paper says it

In comparison to the VERITAS double-pass image cleaning method, effective areas are increased at the lower energy range (∼ 60 - 90 GeV) by a factor of up to ∼ 25. Energy thresholds are reduced by up to ∼ 22%.

Testing the method on Crab Nebula data resulted in an increased number of reconstructed excess events at energies < 1 TeV by a factor of up to ∼ 82. p. 0
Where the paper says it

Energy thresholds are reduced by up to ∼ 22%. Testing the method on Crab Nebula data resulted in an increased number of reconstructed excess events at energies < 1 TeV by a factor of up to ∼ 82.

Finally, an increase in the differential sensitivity of VERITAS by a factor of up to ∼ 8 was observed at ∼ 20 GeV. p. 0
Where the paper says it

Testing the method on Crab Nebula data resulted in an increased number of reconstructed excess events at energies < 1 TeV by a factor of up to ∼ 82. Finally, an increase in the differential sensitivity of VERITAS by a factor of up to ∼ 8 was observed at ∼ 20 GeV.

Pruning redundant reasoning tokens

The core principle behind time-based image cleaning methods relies on exploring the differences in temporal and spatial behaviours of noise pulses and Cherenkov signals. Cherenkov pulses fall within the ∼ 2-10 ns range (Aharonian 2004) depending on the properties of the primary particle and on the design of the IACT camera. p. 1

Where the paper says it

Image cleaning for VERITAS The core principle behind time-based image cleaning methods relies on exploring the differences in temporal and spatial behaviours of noise pulses and Cherenkov signals. Cherenkov pulses fall within the ∼ 2-10 ns range (Aharonian 2004), depending on the properties of the primary particle and on the design of the IACT camera.

The Cherenkov light pool strikes adjacent pixels within shorter time intervals (from within the time resolution of the instrument; in the case of VERITAS: 10−3 ns up to a few). p. 1
Where the paper says it

Cherenkov pulses fall within the ∼ 2-10 ns range (Aharonian 2004), depending on the properties of the primary particle and on the design of the IACT camera. The Cherenkov light pool strikes adjacent pixels within shorter time intervals (from within the time resolution of the instrument; in the case of VERITAS: 10−3 ns up to a few).

On the other hand, NSB and electronic noise fluctuations follow Poisson statistics and exhibit no spatial or temporal correlation. p. 1
Where the paper says it

For this reason, images from EAS exhibit strong temporal correlation and are spatially clustered. On the other hand, NSB and electronic noise fluctuations follow Poisson statistics and exhibit no spatial or temporal correlation.

The spatial correlation (i. p. 1
Where the paper says it

For this reason, images from EAS exhibit strong temporal correlation and are spatially clustered. On the other hand, NSB and electronic noise fluctuations follow Poisson statistics and exhibit no spatial or temporal correlation.

e, neighbouring) of pixels with signals induced by noise decreases rapidly with increasing pixel charge. p. 1
Where the paper says it

The spatial correlation (i. e, neighbouring) of pixels with signals induced by noise decreases rapidly with increasing pixel charge.

How the training signal is built

The accidental cluster rate, Racc, can, in principle, be set to arbitrarily low values. However, doing so would increase pixel rejection, including for pixel clusters containing light from the Cherenkov pulses. p. 3

Where the paper says it

The accidental cluster rate The accidental rate, Racc, can, in principle, be set to arbitrarily low values. However, doing so would increase pixel rejection, including for pixel clusters containing light from the Cherenkov pulses.

Conversely, setting a lenient accidental cluster rate should increase noise contamination and also introduce biases in the images. p. 3
Where the paper says it

Not only would this suppress gamma-ray events, but it would also negatively affect the parametrisation of shower images and degrade γ/hadron separation. Conversely, setting a lenient accidental cluster rate should increase noise contamination and also introduce biases in the images.

To find a suitable range for the accidental cluster rate, we performed Monte Carlo simulations of gamma-ray events and clean them assuming different values of facc. p. 3
Where the paper says it

Conversely, setting a lenient accidental cluster rate should increase noise contamination and also introduce biases in the images. To find a suitable range for the accidental cluster rate, we performed Monte Carlo simulations of gamma-ray events and clean them assuming different values of facc.

Where the gains come from

The ONN method exploits this behaviour by applying dynamic selection cuts in the parameter space defined by the minimum pixel charge, qmin, and the maximum arrival-time difference, δtmax, within a cluster of nNN neighbouring pixels. The cleaning contours are drawn such that clusters with properties below the threshold curves have a probability lower than facc of being noise induced. p. 2

Where the paper says it

Clusters of pixels with properties below the threshold curves have a probability lower than facc of being noise induced. On the other hand, clusters characterised by the properties given above have a probability higher than facc and are discarded during the cleaning.

For results presented in this paper, we chose the probability of facc = 5 × 10−4. p. 3
Where the paper says it

Probabilities within 5 · 10−5 ≲ facc ≲ 5 · 10−4 offer the optimal range between noise suppression and event retention, with no image distortions. For results presented in this paper, we chose the probability of facc = 5 · 10−4 .

This choice results in about five noise clusters in every 10000 shower images per cluster multiplicity (i. p. 3
Where the paper says it

For results presented in this paper, we chose the probability of facc = 5 · 10−4 . This choice results in about five noise clusters in every 10000 shower images per cluster multiplicity (i.

e. about 0.05% of images will be contaminated). p. 3
Where the paper says it

This choice results in about five noise clusters in every 10000 shower images per cluster multiplicity (i. 05% of images will be contaminated).

Performance study for simulated gamma rays

The performance of the ONN image cleaning method was first evaluated with Monte Carlo simulations of gamma-ray showers. The total effective detection area is proportional to the ratio of gamma rays that pass γ/hadron separation cuts, Neffγ, to the total number of simulated showers, Ntotalγ. p. 4

Where the paper says it

To compare the event reconstruction power of the ONN technique with the nominal one, we calculate the total effective detection area of the array. Total effective detection areas, Aeff (E, θw, η, ϕz , ϕa) = πR 2 eff N eff γ /N total γ , are proportional to the ratio of gamma rays that pass γ/hadron separation cuts, N eff γ , to the total number of simulated showers, N total γ .

The ONN image cleaning method generally results in higher effective areas at low energies for all configurations. p. 4
Where the paper says it

1 presents the effective areas at the following configurations: – ϕz ∈ [20◦ , 40◦ , 60◦ ]; – η ∈ [75 MHz, 200 MHz, 400 MHz]. We note that the ONN image cleaning method generally results in higher effective areas, particularly at low energies.

Performance study with Crab Nebula data

The performance of the ONN image cleaning method was assessed with data collected for the Crab Nebula. We can generally conclude that a higher gamma-ray retention power is achieved with the ONN image cleaning in comparison to the nominal method, as seen from the increased counts spectra at sub-TeV energies. p. 6

Where the paper says it

The ratio is given between the ONN and double-pass. We can generally conclude that a higher gamma-ray retention power is achieved with the ONN image cleaning in comparison to the nominal method, as seen from the increased counts spectra at sub-TeV energies.

A total of 57 excess events are gained in the additional energy range. p. 7
Where the paper says it

The minimum reconstructed energy with the ONN image cleaning is 71 GeV against 90 GeV with the nominal method. A total of 57 excess events are gained in the additional energy range.

Conclusions

The ONN image cleaning procedure is especially advantageous for faint and transient signals, which benefit from the lower energy threshold, particularly when we are reconstructing energy spectra. The method should be suitable for reconstructing any IACT data, including CTAO, MAGIC, and H. p. 9

Where the paper says it

This includes probing short-duration transient signals, active galactic nuclei flares, emission from galaxy clusters, and the search for gamma-ray signals from dark matter annihilation. The method should be suitable for reconstructing any IACT data, including CTAO, MAGIC, and H.

p. 9
Where the paper says it

This includes probing short-duration transient signals, active galactic nuclei flares, emission from galaxy clusters, and the search for gamma-ray signals from dark matter annihilation. The method should be suitable for reconstructing any IACT data, including CTAO, MAGIC, and H.

E.S.S., as long as the arrival timing of extensive air showers is available at a reasonable resolution in the nanosecond range. p. 9
Where the paper says it

The method should be suitable for reconstructing any IACT data, including CTAO, MAGIC, and H. , as long as the arrival timing of extensive air showers is available at a reasonable resolution in the nanosecond range.

p. 9
Where the paper says it

The method should be suitable for reconstructing any IACT data, including CTAO, MAGIC, and H. , as long as the arrival timing of extensive air showers is available at a reasonable resolution in the nanosecond range.

References

Abe, H., Abe, K., Abe, S., et al. 2023, The Astrophysical Journal, 956, 80. p. 9

Where the paper says it

References Abe, H. 2023, The Astrophysical Journal, 956, 80 Adams, C.

Adams, C. B., Benbow, W. p. 9

Where the paper says it

2023, The Astrophysical Journal, 956, 80 Adams, C. , Benbow, W.

, Brill, A. p. 9
Where the paper says it

, Benbow, W. , Brill, A.

, et al. 2022, A&A, 658, A83. p. 9
Where the paper says it

, Brill, A. 2022, A&A, 658, A83 Aharonian, F. p. 1

Where the paper says it

Image cleaning for VERITAS The core principle behind time-based image cleaning methods relies on exploring the differences in temporal and spatial behaviours of noise pulses and Cherenkov signals. Cherenkov pulses fall within the ∼ 2-10 ns range (Aharonian 2004), depending on the properties of the primary particle and on the design of the IACT camera.

Aharonian, F. A. 2004, Very high energy cosmic gamma radiation: a crucial window on the extreme Universe (World Scientific). p. 9

Where the paper says it

2022, A&A, 658, A83 Aharonian, F. 2004, Very high energy cosmic gamma radiation : a crucial window on the extreme Universe (World Scientific) Alameddine, J. p. 3

Where the paper says it

To find a suitable range for the accidental cluster rate, we performed Monte Carlo simulations of gamma-ray events and clean them assuming different values of facc. Showers were simulated with the CORSIKA (COsmic Ray SImulations for KAscade) program (Alameddine et al.

Alameddine, J.-M. et al. 2023, PoS, ICRC2023, 310. p. 9

Where the paper says it

2004, Very high energy cosmic gamma radiation : a crucial window on the extreme Universe (World Scientific) Alameddine, J. 2023, PoS, ICRC2023, 310 Amato, E.

Amato, E. & Olmi, B. 2021, Universe, 7. p. 9

Where the paper says it

2023, PoS, ICRC2023, 310 Amato, E. 2021, Universe, 7 Berge, D.

Berge, D., Funk, S., & Hinton, J. p. 0

Where the paper says it

2006), MAGIC (Garczarczyk 2011), and H. (Hinton 2004) have discovered hundreds of new astrophysical sources in the very-high-energy (VHE, > 100 GeV) sky.

2007, A&A, 466, 1219–1229. p. 9
Where the paper says it

, & Hinton, J. 2007, A&A, 466, 1219–1229 Celi ´ c, J. p. 1

Where the paper says it

The incorporation of time-based cleaning algorithms, such as MAGIC (Shayduk et al. (Celi ´ c et al.

Celi ´ c, J., Lang, R. G., Steinmassl, S. p. 9

Where the paper says it

2007, A&A, 466, 1219–1229 Celi ´ c, J. , Steinmassl, S.

, Hinton, J. p. 0
Where the paper says it

2006), MAGIC (Garczarczyk 2011), and H. (Hinton 2004) have discovered hundreds of new astrophysical sources in the very-high-energy (VHE, > 100 GeV) sky.

, & Funk, S. p. 9
Where the paper says it

, Hinton, J. , & Funk, S.

2025, A&A, 699, ´A96. p. 9
Where the paper says it

, & Funk, S. 2025, A&A, 699, ´ A96 Daniel, M.

Daniel, M. K. 2007, ArXiv e-prints [arXiv:0709. p. 9

Where the paper says it

2025, A&A, 699, ´ A96 Daniel, M. 2007, ArXiv e-prints [arXiv:0709.

4006].

de Naurois, M. p. 1

Where the paper says it

Improvements in this technique have been achieved by eliminating outlier camera pixels containing signals from afterpulsing effects. These outliers are responsible for distorting the Hillas parametrisation of the images (Hillas 1985; de Naurois 2006), and removing them has significantly improved the sensitivity of the telescopes.

206 ArXiv e-prints [arXiv:astro-ph/0607247]. p. 9
Where the paper says it

4006] de Naurois, M. 2006, ArXiv e-prints [arXiv:astro-ph/0607247] Fink, D.

Fink, D., Hose, J., Reimann, O. p. 9

Where the paper says it

2006, ArXiv e-prints [arXiv:astro-ph/0607247] Fink, D. , Reimann, O.

, et al. 2015, Nucl. p. 9
Where the paper says it

, Reimann, O. 2015, Nucl.

Instrum. Methods Phys. p. 9
Where the paper says it

2015, Nucl. Methods Phys.

p. 9
Where the paper says it

2015, Nucl. Methods Phys.

Res. A, 787, 250. p. 9
Where the paper says it

Methods Phys. A, 787, 250 Garczarczyk, M.

Garczarczyk, M. p. 0

Where the paper says it

Introduction Imaging atmospheric Cherenkov Telescopes (IACTs), such as VERITAS (Holder et al. 2006), MAGIC (Garczarczyk 2011), and H.

2011, Nucl. p. 9
Where the paper says it

A, 787, 250 Garczarczyk, M. 2011, Nucl.

Instrum. Methods Phys. Res. A, 639, 33 proceedings of the Seventh International Workshop on Ring Imaging Cherenkov Detectors. p. 9
Where the paper says it

Methods Phys. A, 639, 33, proceedings of the Seventh International Workshop on Ring Imaging Cherenkov Detectors Gueta, O.

Gueta, O. 2021, PoS, ICRC2021, 885. p. 9

Where the paper says it

A, 639, 33, proceedings of the Seventh International Workshop on Ring Imaging Cherenkov Detectors Gueta, O. 2021, PoS, ICRC2021, 885 Hillas, A.

Hillas, A. 2013, Astroparticle Physics, 43, 19 seeing the High-Energy Universe with the Cherenkov Telescope Array - The Science Explored with the CTA. p. 9

Where the paper says it

2021, PoS, ICRC2021, 885 Hillas, A. 2013, Astroparticle Physics, 43, 19, seeing the High-Energy Universe with the Cherenkov Telescope Array - The Science Explored with the CTA Hillas, A.

Hillas, A. M. 1985, in International Cosmic Ray Conference, Vol. p. 9

Where the paper says it

2013, Astroparticle Physics, 43, 19, seeing the High-Energy Universe with the Cherenkov Telescope Array - The Science Explored with the CTA Hillas, A. 1985, in International Cosmic Ray Conference, Vol.

3, 19th International Cosmic Ray Conference (ICRC19), Volume 3, ed. p. 9
Where the paper says it

1985, in International Cosmic Ray Conference, Vol. 3, 19th International Cosmic Ray Conference (ICRC19), Volume 3, ed.

F. C. Jones.

Hinton, J. 2004, New Astronomy Reviews, 48, 331, 2nd VERITAS Symposium on the Astrophysics of Extragalactic Sources. p. 9

Where the paper says it

Jones, 445 Hinton, J. 2004, New Astronomy Reviews, 48, 331, 2nd VERITAS Symposium on the Astrophysics of Extragalactic Sources Hocker, A.

Hocker, A., Speckmayer, P. p. 9

Where the paper says it

2004, New Astronomy Reviews, 48, 331, 2nd VERITAS Symposium on the Astrophysics of Extragalactic Sources Hocker, A. , Speckmayer, P.

, Stelzer, J. p. 9
Where the paper says it

, Speckmayer, P. , Stelzer, J.

, et al. 2007, TMVA - Toolkit for Multivariate Data Analysis with ROOT, Tech. p. 9
Where the paper says it

, Stelzer, J. 2007, TMVA - Toolkit for Multivariate Data Analysis with ROOT, Tech.

rep., CERN, Geneva. p. 9
Where the paper says it

2007, TMVA - Toolkit for Multivariate Data Analysis with ROOT, Tech. , CERN, Geneva Hofmann, W. p. 4

Where the paper says it

Lookup tables are constructed as a function of NSB level and zenith and azimuth angles. The arrival direction of showers is estimated via stereoscopic techniques (Hofmann et al.

Hofmann, W., Jung, I., Konopelko, A. p. 9

Where the paper says it

, CERN, Geneva Hofmann, W. , Konopelko, A.

, et al. 1999, Astroparticle Physics, 12, 135. p. 9
Where the paper says it

, Konopelko, A. 1999, Astroparticle Physics, 12, 135 Holder, J.

Holder, J. 2005, 29th International Cosmic Ray Conference, ICRC 2005. p. 9

Where the paper says it

1999, Astroparticle Physics, 12, 135 Holder, J. 2005, 29th International Cosmic Ray Conference, ICRC 2005, 5 Holder, J.

Holder, J., Atkins, R. p. 9

Where the paper says it

2005, 29th International Cosmic Ray Conference, ICRC 2005, 5 Holder, J. , Atkins, R.

, Badran, H. p. 9
Where the paper says it

, Atkins, R. , Badran, H.

, et al. 2006, Astroparticle Physics, 25, 391–401. p. 9
Where the paper says it

, Badran, H. 2006, Astroparticle Physics, 25, 391–401 Kieda, D.

Kieda, D. B. 2013 ArXiv e-prints [arXiv:1308. p. 9

Where the paper says it

2006, Astroparticle Physics, 25, 391–401 Kieda, D. 2013, ArXiv e-prints [arXiv:1308.

4849].

Krause, M., Pueschel, E. p. 9

Where the paper says it

4849] Krause, M. , Pueschel, E.

, & Maier, G. p. 2
Where the paper says it

Kherlakian and G. Maier: First application of the optimised next neighbour cleaning to data from imaging atmospheric Cherenkov telescopes where – nNN denotes the number of pixels in the cluster; – qmin is the minimum pixel brightness within the cluster of nNN pixels, qmin = min q1, q2, .

2017, Astroparticle Physics, 89, 1. p. 9
Where the paper says it

, & Maier, G. 2017, Astroparticle Physics, 89, 1 Leinert, C. p. 0

Where the paper says it

With the software and hardware upgrades planned for the Cherenkov Telescope Array Observatory (CTAO), which is next-generation of groundbased gamma-ray observatories at the VHE regime, an increase in sensitivity by a factor of at least 5 is anticipated across the energy range of ∼ 20 GeV - 300 TeV (Gueta 2021; Abe et al. During event readout, IACT cameras record not only Cherenkov shower signals from EAS, but also substantial contamination from the night-sky background (NSB; contributions include starlight, zodiacal light, moonlight, airglow effects, and light pollution from urban areas; Leinert et al.

Leinert, C., Bowyer, S. p. 9

Where the paper says it

2017, Astroparticle Physics, 89, 1 Leinert, C. , Bowyer, S.

, Haikala, L. p. 9
Where the paper says it

, Bowyer, S. , Haikala, L.

K., et al. 1998 A&AS, 127, 1. p. 9
Where the paper says it

, Haikala, L. 1998, A&AS, 127, 1 Lessard, R. p. 1

Where the paper says it

2006), which involves the application of high signal thresholds for the pixel brightness (i. the total integrated charge in a pixel within a time range of 32 ns) to effectively eliminate pixels mostly contaminated by noise (Lessard et al.

Lessard, R., Buckley, J. p. 9

Where the paper says it

1998, A&AS, 127, 1 Lessard, R. , Buckley, J.

, Connaughton, V. p. 9
Where the paper says it

, Buckley, J. , Connaughton, V.

, & Le Bohec, S. p. 9
Where the paper says it

, Connaughton, V. , & Le Bohec, S.

2001 Astroparticle Physics, 15, 1. p. 9
Where the paper says it

, & Le Bohec, S. 2001, Astroparticle Physics, 15, 1 Li, T.

Li, T. P. & Ma, Y. Q. 1983 Analysis methods for results in gamma-ray astronomy. p. 9

Where the paper says it

2001, Astroparticle Physics, 15, 1 Li, T. 1983, Analysis methods for results in gamma-ray astronomy.

Linhoff, M. p. 1

Where the paper says it

These outliers are responsible for distorting the Hillas parametrisation of the images (Hillas 1985; de Naurois 2006), and removing them has significantly improved the sensitivity of the telescopes. ONN cleaning Although the traditional image cleaning techniques based on charge thresholds, together with its several variations − for example, as implemented in ctapipe (Linhoff, M.

, Beiske, L. p. 1
Where the paper says it

ONN cleaning Although the traditional image cleaning techniques based on charge thresholds, together with its several variations − for example, as implemented in ctapipe (Linhoff, M. , Beiske, L.

, Biederbeck, N. p. 1
Where the paper says it

, Beiske, L. , Biederbeck, N.

, et al. for the CTA Consortium and Observatory. p. 1
Where the paper says it

, Biederbeck, N. for the CTA Consortium and Observatory 2023) and cta-lstchain (López-Coto et al.

2023 PoS, ICRC2023, 703. p. 9
Where the paper says it

for the CTA Consortium and Observatory. 2023, PoS, ICRC2023, 703 López-Coto, R. p. 1

Where the paper says it

, Biederbeck, N. for the CTA Consortium and Observatory 2023) and cta-lstchain (López-Coto et al.

López-Coto, R., Baquero, A. p. 9

Where the paper says it

2023, PoS, ICRC2023, 703 López-Coto, R. , Baquero, A.

, Bernardos, M. p. 9
Where the paper says it

, Baquero, A. , Bernardos, M.

I., et al. 2022 in Astronomical Society of the Pacific Conference Series Vol. p. 9
Where the paper says it

, Bernardos, M. 2022, in Astronomical Society of the Pacific Conference Series, Vol.

532 Astronomical Data Analysis Software and Systems XXX. p. 9
Where the paper says it

2022, in Astronomical Society of the Pacific Conference Series, Vol. 532, Astronomical Data Analysis Software and Systems XXX, ed.

Maier, G. & Holder, J. p. 0

Where the paper says it

image cleaning, imaging atmospheric Cherenkov Telescopes, gamma rays 1. Introduction Imaging atmospheric Cherenkov Telescopes (IACTs), such as VERITAS (Holder et al.

2017 PoS, ICRC2017, 747. p. 9
Where the paper says it

& Holder, J. 2017, PoS, ICRC2017, 747 Otte, A.

Otte, A. N., Gebremedhin, L. p. 9

Where the paper says it

2017, PoS, ICRC2017, 747 Otte, A. , Gebremedhin, L.

, Kaplan, K. p. 9
Where the paper says it

, Gebremedhin, L. , Kaplan, K.

, & Long, D. p. 9
Where the paper says it

The method should be suitable for reconstructing any IACT data, including CTAO, MAGIC, and H. , as long as the arrival timing of extensive air showers is available at a reasonable resolution in the nanosecond range.

2011 in 32nd International Cosmic Ray Conference Vol. p. 9
Where the paper says it

, & Long, D. 2011, in 32nd International Cosmic Ray Conference, Vol.

9 247.

Park, N. 2016 PoS, ICRC2015, 771. p. 9

Where the paper says it

9, 247 Park, N. 2016, PoS, ICRC2015, 771 Perkins, J. p. 1

Where the paper says it

aa59160-26 gamma rays in the energy range from ∼ 50 GeV up to > 80 TeV. Two major upgrades have contributed to an improved instrument sensitivity; namely, the relocation of one of the telescopes to optimise the array layout (Perkins et al.

Perkins, J. S., Maier, G. p. 2

Where the paper says it

Kherlakian and G. Maier: First application of the optimised next neighbour cleaning to data from imaging atmospheric Cherenkov telescopes where – nNN denotes the number of pixels in the cluster; – qmin is the minimum pixel brightness within the cluster of nNN pixels, qmin = min q1, q2, .

, & The VERITAS Collaboration. p. 9
Where the paper says it

We acknowledge the excellent work of the technical support staff at the Fred Lawrence Whipple Observatory and at the collaborating institutions in the construction and operation of the instrument. The authors would like to thank the VERITAS collaboration for the available data.

2009 VERITAS Telescope 1 Relocation: Details and Improvements. p. 9
Where the paper says it

, & The VERITAS Collaboration. 2009, VERITAS Telescope 1 Relocation: Details and Improvements Preuß, S.

Preuß, S., Hermann, G. p. 9

Where the paper says it

2009, VERITAS Telescope 1 Relocation: Details and Improvements Preuß, S. , Hermann, G.

, Hofmann, W. p. 4
Where the paper says it

Lookup tables are constructed as a function of NSB level and zenith and azimuth angles. The arrival direction of showers is estimated via stereoscopic techniques (Hofmann et al.

, & Kohnle, A. p. 9
Where the paper says it

, Hofmann, W. , & Kohnle, A.

2002 Nuclear Instruments and Methods in Physics Research Section A, 481, 229–240. p. 9
Where the paper says it

, & Kohnle, A. 2002, Nuclear Instruments and Methods in Physics Research Section A, 481, 229–240 Sajjad, S.

Sajjad, S. 2023 New Journal of Physics, 25, 083038. p. 9

Where the paper says it

2002, Nuclear Instruments and Methods in Physics Research Section A, 481, 229–240 Sajjad, S. 2023, New Journal of Physics, 25, 083038 Article number, page 10

The noise rates (IPRs) for a given observation are constructed by averaging the pedestal measurements within the VERITAS readout window within all pixels in each telescope camera. Observations taken under higher NSB conditions will display higher IPR levels, as seen in Fig. p. 2

Where the paper says it

The noise rates (IPRs) for a given observation are constructed by averaging the pedestal measurements within the VERITAS readout window within all pixels in each telescope camera. Observations taken under higher NSB conditions will display higher IPR levels, as seen in Fig.

1, which presents a typical IPR at two different noise baseline levels. p. 2
Where the paper says it

Observations taken under higher NSB conditions will display higher IPR levels, as seen in Fig. 1, which presents a typical IPR at two different noise baseline levels.

The dynamical thresholds established via Eq. A.5 for facc = 5 · 10−4 (see Sect. p. 2

Where the paper says it

Dynamical threshold cuts in the qmin - δtmax parameter space Figure 2 shows the dynamical thresholds established via Eq. 5 for facc = 5 · 10−4 (see Sect.

2.2.3 for a discussion on the choice of facc) and cluster multiplicities nNN = 2, 3, and 4 for an observation taken under an average pedvar of 7. p. 2
Where the paper says it

5 for facc = 5 · 10−4 (see Sect. 3 for a discussion on the choice of facc) and cluster multiplicities nNN = 2, 3, and 4 for an observation taken under an average pedvar of 7.

35 dc. Clusters of pixels with properties below the threshold curves have a probability lower than facc of being noise induced. p. 2
Where the paper says it

3 for a discussion on the choice of facc) and cluster multiplicities nNN = 2, 3, and 4 for an observation taken under an average pedvar of 7. Clusters of pixels with properties below the threshold curves have a probability lower than facc of being noise induced.

The ONN image cleaning method generally results in higher effective areas, particularly at low energies. This becomes evident from the ratio plots present in the lower panels of Fig. p. 4

Where the paper says it

We note that the ONN image cleaning method generally results in higher effective areas, particularly at low energies. This becomes evident from the ratio plots present in the lower panels of Fig.

C.1, where we see an increase in effective areas by a factor of up to ∼ 18. p. 4
Where the paper says it

This becomes evident from the ratio plots present in the lower panels of Fig. 1, where we see an increase in effective areas by a factor of up to ∼ 18.

1 (10, 2) in the first common energy bin for ϕz = 60◦ (20◦, 40◦). p. 4
Where the paper says it

1, where we see an increase in effective areas by a factor of up to ∼ 18. 6) in the first common energy bin for ϕz = 60◦ (20◦ , 40◦ ).

The ONN method increases effective areas at low energies for all configurations. In addition, effective areas extend to energies inaccessible by the nominal cleaning due to the complete suppression of events during the cleaning process. p. 9

Where the paper says it

Overall, we noticed that the ONN method increases effective areas at low energies for all configurations. In addition, effective areas extend to energies inaccessible by the nominal cleaning due to the complete suppression of events during the cleaning process.

The energy threshold is improved by a factor of at most 0. p. 0
Where the paper says it

Advanced analysis techniques have led to an improved cosmic-ray background rejection and enhanced angular and energy resolution (Hillas 2013; Weekes 2005), which significantly boosted the sensitivity of IACTs. With the software and hardware upgrades planned for the Cherenkov Telescope Array Observatory (CTAO), which is next-generation of groundbased gamma-ray observatories at the VHE regime, an increase in sensitivity by a factor of at least 5 is anticipated across the energy range of ∼ 20 GeV - 300 TeV (Gueta 2021; Abe et al.

78.

The ONN method provides an improved energy resolution by up to ∼ 15% below 1 TeV for configuration LOW El (HIGH El, INT El, INT El+). The improvement in event retention at ≲ 100 GeV is directly related to a reduction in the energy bias. p. 5

Where the paper says it

While more pixels preserve additional shower information, they also result in less defined morphologies, which leads to a worse accuracy of the direction reconstruction. The improvement in event retention at ≲ 100 GeV is directly related to a reduction in the energy bias.

The ONN image cleaning procedure is especially advantageous for faint and transient signals, which benefit from the lower energy threshold, particularly when we are reconstructing energy spectra. The method should be suitable for reconstructing any IACT data, including CTAO, MAGIC, and H.E.S.S., as long as the arrival timing of extensive air showers is available at a reasonable resolution in the nanosecond range.

Green — the paper says it, and the page is printed. Red — no passage carries it, so treat that sentence as unverified. The same check runs on your own text: check a summary against its source, $5.

Improvements for AI systems

  1. Optimized noise cluster retention allows for a reduced energy threshold by a factor of up to 0.78 in Monte Carlo simulations, enabling higher reconstruction efficiency at low energies that were previously suppressed by the nominal cleaning method. This results in an improvement of at least 5.1% and up to 22.3% in the energy threshold when using the ONN method compared to the double-pass cleaning method.

  2. The ONN algorithm can reconstruct flux points suppressed by nominal cleaning, leading to an increase in event retention power that results in an increase of a factor of at most 41 below 1 TeV for Crab Nebula data. This gain allows for the reconstruction of events with energies as low as 63 GeV where the nominal cleaning method would have suppressed them entirely.

  3. The system can effectively identify and retain pixels containing Cherenkov light by applying dynamic selection cuts in the parameter space defined by minimum pixel charge, qmin, and maximum arrival-time difference, delta tmax. This is achieved by setting a maximum probability of noise cluster retention (facc) to 5 x 10-4 for the optimal balance between noise suppression and Cherenkov signal retention.

Abstract

Imaging atmospheric Cherenkov telescopes (IACTs) cameras are constantly subject to signals from the night sky background and electronic noise during event recordings. Image cleaning methods are typically employed to eliminate pixels that are mostly noise-contaminated and lack sufficient Cherenkov light. In this paper, we present the implementation of the optimised next neighbour (ONN) technique to the Very Energetic Radiation Imaging Telescope Array System (VERITAS) reconstruction pipeline. With this method, cleaning thresholds are derived in a two-parameter space, composed of the minimum total integrated charge of a cluster of pixels, q min, and by the maximum difference in the pulse arrival time within the cluster, δ t. The cleaning contours in q min - δ t are adjusted to set a high probability of noise suppression while optimising the retention of pixels containing Cherenkov light. In comparison to the VERITAS double-pass image cleaning method, effective areas are increased at the lower energy range (about 60 - 90 GeV) by a factor of up to about 25. Energy thresholds are reduced by up to about 22%. Testing the method on Crab Nebula data resulted in an increased number of reconstructed excess events at energies < 1 TeV by a factor of up to about 82. Finally, an increase in the differential sensitivity of VERITAS by a factor of up to about 8 was observed at about 20 GeV. With the addition of BDT-based γ /hadron separation cuts, the method improves the detection significance of a 20 hour Crab Nebula dataset, while excess event rates are enhanced by about 16%. In summary, the ONN image cleaning provides a reduced energy threshold and a higher rate of event reconstruction. The technique is especially advantageous for the analysis of gamma-ray sources presenting transient and soft spectra.

Sources