The General Antiparticle Spectrometer (GAPS) Antarctic Balloon Payload

arXiv:2604.19830 · astro-ph.IM, physics.ins-det · Submitted 2026-04-20 · Read on arXiv

Listen

Radio episode about this paper

Transcript

Introduction to the show: ident: Astrophysics. The day in astrophysics: observations, models and what the data forces.

Vera: We're looking at the paper: "The General Antiparticle Spectrometer (GAPS) Antarctic Balloon Payload".

Jocelyn: Here's the gist of the paper. The General Antiparticle Spectrometer (GAPS) Antarctic Balloon Payload is designed to provide unmatched sensitivity to low-energy cosmic-ray antiprotons, antideuterons, and antihelium nuclei as signatures of dark matter The first GAPS science payload was integrated, tested, and calibrated on the ground from 2022 – 2024 Mission Objectives The GAPS mission is specifically designed to meet the challenges of low-energy cosmic-ray antinucleus detection The payload is the first instrument capable of enabling cosmic-ray antinucleus science spanning the kinetic energy range of 0.10 − 0.25 GeV/n It aims to detect low-energy (< 0.25 GeV/n) cosmic-ray antiprotons, antideuterons, and antihelium nuclei as signatures of dark matter The program will also measure the cosmic-ray antiproton (p) spectrum in a lower energy regime than any other experiment Particle Identification Technique The distinctive GAPS particle identification technique relies on measuring the energy loss along the track of an incoming antinucleus as it slows down and is captured into an exotic atom, and the detecting deexcitation X-rays and the nuclear annihilation products This technique provides robust rejection of positive nuclei and discrimination between antinucleus species Species can be distinguished based on the combination of its incident energy-loss patterns and the resulting X-ray energies and hadron multiplicity The abundant positive nuclei do not form exotic atoms and can thus be rejected Engineering Solutions The design principles require a high-altitude polar platform, a combination of large instrument acceptance and long observation time for sensitivity to rare d fluxes of the order 10−6

m2 s sr (GeV/n): −1 at the top of the atmosphere The GAPS instrument is illustrated in Fig.

Vera: 1 The Tracker is a central 1.6 m×1.6 m×1.0 m volume with 10 layers A multi-loop capillary heat pipe system has been developed to maintain the tracker operating temperature with significant mass and power savings over a conventional pump-based system The Tracker is cooled to an operating temperature of < −35°C by a multi-loop capillary heat pipe (MCHP) system that transports heat from the warm Tracker electronics to a ∼9 m2 radiator oriented towards space Detector Subsystems The GAPS instrument consists of a Tracker with > 1000 custom Si(Li) detectors, surrounded on all sides by a plastic scintillator TOF system The Tracker provides a target capable of stopping d with energies up to 0.25 GeV/n, measuring energy depositions from 20 keV to 100 MeV The TOF provides a high-speed system trigger, particle velocity and energy deposition measurements, and further timing and position information for particle tracking The Time-of-Flight (TOF) system delivers a measurement of the primary particle’s velocity v with ∆β ≡ ∆v/c ∼ 0.1 (1σ) over the full β range System Integration and Operation The gondola frame must withstand shocks up to ∼8 g vertical and ∼4 g horizontal on the total instrument weight of 2875 kg The Gondola Control Unit (GCU) manages the data acquisition activities of the Tracker and TOF subsystems, facilitates packaging and telemetry of both science and housekeeping data The online GCU software merges the science data from the Tracker and TOF subsystems by matching TOF packets and Tracker packets by EVENT ID The GCU performs an online classification to flag antinucleus-like events for priority transmission The GAPS sensitivity is possible on a balloon platform thanks to the novel exotic atom-based particle identification method that delivers robust background rejection without a magnet GAPS is an Antarctic LDB mission specifically designed to meet the challenges of low-energy cosmic-ray antinucleus detection The Tracker provides a highacceptance target that can stop cosmic-ray particles in this energy range while resolving the exotic atom de-excitation X-rays and annihilation products The TOF provides a high-speed system trigger with a wide-angle acceptance and a velocity measurement with ∆β(1σ) < 0.1c, as well as additional tracking information The GAPS sensitivity is possible on a balloon platform thanks to the novel exotic atom-based particle identification method that delivers robust background rejection without a magnet Acknowledgment We are grateful to the team at Columbia Scientific Balloon Facility for their enduring commitment to letting GAPS fly and for their superlative support of our team and our science over the past several years We thank NASA’s Balloon Program Office for their support We are also indebted to the Antarctic Support Contract’s LDB team who moved mountains (of snow and of snacks) to keep the balloon facility running through all conditions Sincere thanks are due to the staff at MIT’s Bates Laboratory, the University of California, Berkeley’s Space Sciences Laboratory (SSL), and Columbia University’s Nevis Laboratory for their support during the on-site integration and testing of the GAPS science payload The GAPS team at SSL is grateful to the NCT, COSI, and GRIPS balloon teams for a tradition of sharing resources and expertise to allow mutual success We also thank John Tomsick for his continued support of the GAPS program and specifically for enabling the contributions of F.

Jocelyn: Rogers This work is supported in the U.S.

Vera: by NASA Astrophysics Research and Analysis GAPS grants (NNX17AB44G, NNX17AB46G, NNX17AB47G) PI, C.

Paper summary: Vera: So to recap, this paper on "The General Antiparticle Spectrometer (GAPS) Antarctic Balloon Payload" is about an LDB mission intended to find low-energy cosmic ray antiprotons, antideuterons, and antihelium nuclei as potential dark matter signals.

Jocelyn: The core of their proposal is the particle identification method: measuring the energy loss of a slowing antinucleus while it forms an exotic atom, and then detecting the resulting de-excitation X-rays and annihilation products.

Subrahmanyan: The importance lies in using this specific measurement to distinguish these rare antinucleus signals from the abundant positive nucleus backgrounds, which can't form those exotic atoms.

Vera: They’ve built a large Tracker with over one thousand silicon strip detectors and a plastic scintillator time-of-flight system that covers more than forty square meters of area.

Jocelyn: This combination provides the necessary velocity and energy resolution, stopping power to capture particles up to zero point two five gigaelectron volts per nucleon, and the tracking information needed for particle identification.

Subrahmanyan: Beyond just detecting these particles, they are also setting out to measure the cosmic ray antiproton spectrum in a lower energy regime than any other existing experiment has managed.

Vera: To keep this massive instrument functional at high altitude, they developed a multi-loop capillary heat pipe system that reduces mass and power compared to conventional pump systems.

Jocelyn: This thermal solution is crucial because it allows the tracker to operate at a very cold temperature, less than minus thirty five degrees Celsius, while efficiently transporting heat away using a radiator oriented toward space.

Subrahmanyan: The implication is that if they achieve their sensitivity goals, they will be providing constraints on the mass and interaction cross section of dark matter candidates through these antinucleus fluxes.

Vera: So basically, it’s a complex instrument built for extreme conditions that uses a unique physics technique to hunt for very rare cosmic rays that could point toward new physics.

Jocelyn: It's an ambitious mission designed to bridge the gap between current particle detection capabilities and searching for dark matter signatures in the low-energy cosmic ray sector.

Subrahmanyan: It’s a test of whether this specific identification method can yield results comparable to what magnetic spectrometers have found, given the lower energy range they are targeting.

Conclusion: Vera: So we've gone over the GAPS Antarctic Balloon Payload paper, focusing on what it claims about searching for dark matter through low-energy antinuclei detection.

Jocelyn: The authors describe a mission designed to find those specific particle signatures—antiprotons, antideuterons, and antihelium nuclei—as dark matter candidates.

Subrahmanyan: The paper highlights the unique physics of using exotic atom de-excitation X-rays and annihilation products to differentiate these signals from standard positive nucleus backgrounds.

Vera: It’s about proving that this specific measurement approach provides a way to get robust background rejection without needing a magnetic field for particle separation.

Jocelyn: The overall implication is that if they succeed in achieving their sensitivity goals, they will be contributing new data to the cosmic ray spectrum in a lower energy range.

Subrahmanyan: It’s about providing constraints on dark matter models by measuring these fluxes, which could narrow down the possible parameters for those theoretical models.

Vera: The GAPS mission is an Antarctic LDB effort focusing on achieving this sensitivity using an exotic atom-based identification method on a balloon platform.

Jocelyn: It’s a demonstration of how sophisticated thermal engineering and large-scale detector integration can work together under challenging flight conditions to perform this kind of sensitive physics.

Subrahmanyan: Ultimately, it’s about pushing the limits of what we can measure in the cosmic ray sector to find evidence that connects these antinuclei fluxes to dark matter annihilation models.

Institute of Space and Astronautical Science, Japan Aerospace Exploration Agency (ISAS/JAXA · Northeastern University · University of California, Los Angeles · INFN Sezione di Trieste · IFPU I-34014 Trieste · Department of Astronomy & Astrophysics University of California San Diego La Jolla CA 90037 · Columbia Astrophysics Laboratory Columbia University New York NY 10027 · INFN Sezione di Napoli I-80126 Naples · iSpace Sciences Laboratory University of California Berkeley 7 Gauss Way Berkeley CA 94720 · University of Hawaii at Manoa Honolulu HI 96822 USA · Oak Ridge National Laboratory Oak Ridge TN 37831 USA · INFN Sezione di Pavia I-27100 Pavia Italy · Università di Bergamo I-24044 Dalmine BG Italy · Tokai University Hiratsuka Kanagawa 259-1292 Japan · Polar Environment Data Science Center Joint Support-Center for Data Science Research Research Organization of Information and Systems Tachikawa Tokyo 190-0014 Japan · Università di Napoli Federico II I-80138 Naples Italy · Università di Pavia I-27100 Pavia Italy · Kavli Institute for Cosmological Physics University of Chicago 5640 S Ellis Ave Chicago IL 60637 USA · Kanagawa University Yokohama Kanagawa 221-8686 Japan · Università di Trento Dipartimento di Fisica V Sommarive 14 Trento Italy · Università di Roma Tor Vergata I-00133 Rome Italy · INFN Sezione di Firenze I-50019 Sesto Fiorentino Florence Italy

astro-ph.IM, physics.ins-det

Submitted: 2026-04-20

Updated: 2026-11-10

Comments: 16 pages, 12 figures, in press at NIM A

DOI: 10.1016/j.nima.2026.172167

License: http://creativecommons.org/licenses/by-nc-nd/4.0/

Importance score: 100/100

The gist: The General Antiparticle Spectrometer (GAPS) Antarctic Balloon Payload is designed to provide unmatched sensitivity to low-energy cosmic-ray antiprotons, antideuterons…

Key concepts

Exotic Atom Capture
When an incoming antinucleus slows down within the detector, it can be captured into a temporary exotic atom. This capture process is key because it allows scientists to measure the energy loss along the particle's path. This measurement helps distinguish true antinuclei from unwanted positive nuclei backgrounds.
Particle Identification Technique
GAPS identifies particles by measuring three things: how much energy they lose while slowing down, the resulting de-excitation X-rays emitted by the atom, and the products of nuclear annihilation. This combination provides a powerful method to separate rare antinucleus signals from common positive nuclei that do not form these exotic atoms.
Multi-loop Capillary Heat Pipe (MCHP)
To keep the sensitive tracker components at a very low operating temperature (< -35°C), a novel MCHP system was developed. This system moves heat from the warm electronics to a radiator facing space with minimal mass and power compared to traditional pumps, which is crucial for maintaining high performance in the extreme Antarctic environment.

Terminology

Summary

The General Antiparticle Spectrometer (GAPS) Antarctic Balloon Payload is designed to provide unmatched sensitivity to low-energy cosmic-ray antiprotons, antideuterons, and antihelium nuclei as signatures of dark matter The first GAPS science payload was integrated, tested, and calibrated on the ground from 2022 – 2024

Mission Objectives

The GAPS mission is specifically designed to meet the challenges of low-energy cosmic-ray antinucleus detection The payload is the first instrument capable of enabling cosmic-ray antinucleus science spanning the kinetic energy range of 0.10 − 0.25 GeV/n It aims to detect low-energy (< 0. p. 1

Where the paper says it

Introduction The General Antiparticle Spectrometer (GAPS) [1, 2, 3] is the first experiment optimized to detect low-energy (kinetic energy ≲0. 25 GeV/n) cosmic-ray antideuterons (d).

25 GeV/n) cosmic-ray antiprotons, antideuterons, and antihelium nuclei as signatures of dark matter The program will also measure the cosmic-ray antiproton (p) spectrum in a lower energy regime than any other experiment

Particle Identification Technique

The distinctive GAPS particle identification technique relies on measuring the energy loss along the track of an incoming antinucleus as it slows down and is captured into an exotic atom, and the detecting deexcitation X-rays and the nuclear annihilation products This technique provides robust rejection of positive nuclei and discrimination between antinucleus species Species can be distinguished based on the combination of its incident energy-loss patterns and the resulting X-ray energies and hadron multiplicity The abundant positive nuclei do not form exotic atoms and can thus be rejected

Engineering Solutions

The design principles require a high-altitude polar platform, a combination of large instrument acceptance and long observation time for sensitivity to rare d fluxes of the order 10−6 [m2 s sr (GeV/n)]−1 at the top of the atmosphere The GAPS instrument is illustrated in Fig. 1 The Tracker is a central 1. p. 2

Where the paper says it

The GAPS instrument is illustrated in Fig. The Tracker is a central 1.

6 m×1.6 m×1.0 m volume with 10 layers A multi-loop capillary heat pipe system has been developed to maintain the tracker operating temperature with significant mass and power savings over a conventional pump-based system The Tracker is cooled to an operating temperature of < −35°C by a multi-loop capillary heat pipe (MCHP) system that transports heat from the warm Tracker electronics to a ∼9 m2 radiator oriented towards space

Detector Subsystems

The GAPS instrument consists of a Tracker with > 1000 custom Si(Li) detectors, surrounded on all sides by a plastic scintillator TOF system The Tracker provides a target capable of stopping d with energies up to 0.25 GeV/n, measuring energy depositions from 20 keV to 100 MeV The TOF provides a high-speed system trigger, particle velocity and energy deposition measurements, and further timing and position information for particle tracking The Time-of-Flight (TOF) system delivers a measurement of the primary particle’s velocity v with ∆β ≡ ∆v/c ∼ 0. p. 2

Where the paper says it

25 GeV/n, measuring energy depositions from 20 keV to 100 MeV, and providing approximately cm-scale resolution for particle tracking, sufficient for the scientific goals. The TOF provides a high-speed system trigger, particle velocity and energy deposition measurements, and further timing and position information for particle tracking.

1 (1σ) over the full β range

System Integration and Operation

The gondola frame must withstand shocks up to ∼8 g vertical and ∼4 g horizontal on the total instrument weight of 2875 kg The Gondola Control Unit (GCU) manages the data acquisition activities of the Tracker and TOF subsystems, facilitates packaging and telemetry of both science and housekeeping data The online GCU software merges the science data from the Tracker and TOF subsystems by matching TOF packets and Tracker packets by EVENT ID The GCU performs an online classification to flag antinucleus-like events for priority transmission The GAPS sensitivity is possible on a balloon platform thanks to the novel exotic atom-based particle identification method that delivers robust background rejection without a magnet

Conclusion

GAPS is an Antarctic LDB mission specifically designed to meet the challenges of low-energy cosmic-ray antinucleus detection The Tracker provides a highacceptance target that can stop cosmic-ray particles in this energy range while resolving the exotic atom de-excitation X-rays and annihilation products The TOF provides a high-speed system trigger with a wide-angle acceptance and a velocity measurement with ∆β(1σ) < 0.1c, as well as additional tracking information The GAPS sensitivity is possible on a balloon platform thanks to the novel exotic atom-based particle identification method that delivers robust background rejection without a magnet

Acknowledgment

We are grateful to the team at Columbia Scientific Balloon Facility for their enduring commitment to letting GAPS fly and for their superlative support of our team and our science over the past several years We thank NASA’s Balloon Program Office for their support We are also indebted to the Antarctic Support Contract’s LDB team who moved mountains (of snow and of snacks) to keep the balloon facility running through all conditions Sincere thanks are due to the staff at MIT’s Bates Laboratory, the University of California, Berkeley’s Space Sciences Laboratory (SSL), and Columbia University’s Nevis Laboratory for their support during the on-site integration and testing of the GAPS science payload The GAPS team at SSL is grateful to the NCT, COSI, and GRIPS balloon teams for a tradition of sharing resources and expertise to allow mutual success We also thank John Tomsick for his continued support of the GAPS program and specifically for enabling the contributions of F. Rogers This work is supported in the U. p. 0

Where the paper says it

edu (Field R. Rogers) arXiv:2604.

S. by NASA Astrophysics Research and Analysis GAPS grants (NNX17AB44G, NNX17AB46G, NNX17AB47G) PI, C. p. 1
Where the paper says it

A multi-loop capillary heat pipe system has been developed to maintain the tracker operating temperature with significant mass and power savings over a conventional pump-based system. The first GAPS science payload flew for 25 days during the 2025/26 NASA Antarctic balloon campaign.

Hailey, in Japan by JAXA/ISAS Small Science Program FY2017, and in Italy by Istituto Nazionale di Fisica Nucleare (INFN) and by the Italian Space Agency through the ASI INFN agreement n. p. 0
Where the paper says it

Ongc , Giuseppe Osteriah , Francesco Palmap , Kaliroë Pappasg , Kerstin Perezg , Francesco Perfettoh,t, Lodovico Rattil,u , Valerio Rel,m, Elisa Riceputil,m, Field R. Rogersi,∗ , Brandon Roachv , Nathan Saffoldw, Suzuto Sakamotox , Pratiksha Sawantp,y, Valentina Scottih,t, Yuki Shimizux , Roberta Sparvolip,z, Achim Stoesslj , Arathi Surajb , Alessio Tiberioaa,ab , Grace Tytusj , Elena Vannucciniaa, Sarah Vickersg , Luigi Volpicellip,ac, Zhen Wuad, Mengjiao Xiaoad, Jinghe Yangad , Kelsey Yeeg,ae, Tetsuya Yoshidaa , Gianluigi Zampad , Jiancheng Zengb , Jeffrey Zweerinkc a Institute of Space and Astronautical Science, Japan Aerospace Exploration Agency (ISAS/JAXA), Sagamihara, Kanagawa 252-5210, Japan.

2018-28-HH.0 H. Fuke is supported by JSPS KAKENHI grants (JP17H01136, JP19H05198, JP22KK0042, and JP22H00147) K. p. 2
Where the paper says it

Supporting electronics and on-board computing are housed in the lower electronics bay. An antenna boom supported by the Top-frame supports antennas used for telemetry.

Perez, G. Bridges, K. p. 0
Where the paper says it

∗Corresponding authors Email addresses: glb2139@columbia. edu (Gabriel Bridges), fieldr@berkeley.

Pappas, and S. Vickers are supported by Heising-Simons Foundation awards 2023-4617 and 2025-6055 R.A. Ong receives support from the UCLA Division of Physical Sciences Oak Ridge National Laboratory is operated by UT-Battelle, LLC, under contract DE-AC05-00OR22725 with the U. p. 0
Where the paper says it

jUniversity of Hawaii at Manoa, Honolulu, HI 96822 USA. kOak Ridge National Laboratory, Oak Ridge, TN 37831, USA.

S. Department of Energy (DOE) S. p. 1
Where the paper says it

Abstract The General Antiparticle Spectrometer (GAPS) is an Antarctic stratospheric balloon mission designed to provide unmatched sensitivity to low-energy (< 0. 25 GeV/n) cosmic-ray antiprotons, antideuterons, and antihelium nuclei as signatures of dark matter.

Feldman was supported through the National Science Foundation Graduate Research Fellowship under grant 2034835 The contributions of C. p. 0
Where the paper says it

nTokai University, Hiratsuka, Kanagawa 259-1292, Japan. oPolar Environment Data Science Center, Joint Support-Center for Data Science Research (PEDSC/ROIS-DS), Research Organization of Information and Systems, Tachikawa, Tokyo 190-0014, Japan.

Gerrity were supported by NASA under award No. p. 2
Where the paper says it

Supporting electronics and on-board computing are housed in the lower electronics bay. An antenna boom supported by the Top-frame supports antennas used for telemetry.

80NSSC19K1425 of the Future Investigators in NASA Earth and Space Science and Technology (FINESST) program K. p. 1
Where the paper says it

In addition to antinuclei, GAPS will also produce spectra for low-energy cosmic-ray positive nuclei including protons, deuterons, and helium-3. The GAPS program consists of several flights on NASA’s Antarctic long-duration balloon (LDB) platform.

Yee is supported through the National Science Foundation Graduate Research Fellowship under grant 2141064 K. p. 0
Where the paper says it

nTokai University, Hiratsuka, Kanagawa 259-1292, Japan. oPolar Environment Data Science Center, Joint Support-Center for Data Science Research (PEDSC/ROIS-DS), Research Organization of Information and Systems, Tachikawa, Tokyo 190-0014, Japan.

Aoyama receives support from JSPS KAKENHI grant JP24K22891 M. p. 5
Where the paper says it

Eight Odyssey PC1100 12 V lead-acid batteries are connected pairwise for a 24 V system. Considering voltage drop in transmission, the payload receives power at 19 − 29 V depending on the battery charge state.

Kozai receives support from JSPS KAKENHI grant JP20K14505 K. p. 5
Where the paper says it

Eight Odyssey PC1100 12 V lead-acid batteries are connected pairwise for a 24 V system. Considering voltage drop in transmission, the payload receives power at 19 − 29 V depending on the battery charge state.

Mizukoshi receives support from JSPS KAKENHI grants (JP22K20375 and JP24K17079) S. p. 5
Where the paper says it

Eight Odyssey PC1100 12 V lead-acid batteries are connected pairwise for a 24 V system. Considering voltage drop in transmission, the payload receives power at 19 − 29 V depending on the battery charge state.

Okazaki receives support from JSPS KAKENHI grants (JP18K13928 and JP22KK0042) Y. p. 5
Where the paper says it

Eight Odyssey PC1100 12 V lead-acid batteries are connected pairwise for a 24 V system. Considering voltage drop in transmission, the payload receives power at 19 − 29 V depending on the battery charge state.

Shimizu receives support from JSPS KAKENHI grants (JP20K04002, JP22KK0042, JP23K03436) M. p. 5
Where the paper says it

Eight Odyssey PC1100 12 V lead-acid batteries are connected pairwise for a 24 V system. Considering voltage drop in transmission, the payload receives power at 19 − 29 V depending on the battery charge state.

Xiao, Z. Wu and J. Yang receive support from Yangyang Development Fund The technical support and advanced computing resources from University of Hawaii Information Technology Services – Cyberinfrastructure, funded in part by the National Science Foundation MRI Grant No. p. 0
Where the paper says it

nTokai University, Hiratsuka, Kanagawa 259-1292, Japan. oPolar Environment Data Science Center, Joint Support-Center for Data Science Research (PEDSC/ROIS-DS), Research Organization of Information and Systems, Tachikawa, Tokyo 190-0014, Japan.

1920304, are appreciated This research was performed using resources provided by the Open Science Grid [39, 40, 41, 42] which is supported by the National Science Foundation Grant Nos. p. 0
Where the paper says it

nTokai University, Hiratsuka, Kanagawa 259-1292, Japan. oPolar Environment Data Science Center, Joint Support-Center for Data Science Research (PEDSC/ROIS-DS), Research Organization of Information and Systems, Tachikawa, Tokyo 190-0014, Japan.

2030508 and 2323298 The references are listed at the end of the paper

References

[1] Mori, K. et al. A novel antimatter detector based on X-ray deexcitation of exotic atoms. p. 1

Where the paper says it

The GAPS Antarctic flight program will provide nearly two orders-ofmagnitude improvement in d sensitivity compared to the current limits [8, 12], extending into an unprobed energy range where the significant DM signals would exist. GAPS uses a novel particle identification technique based on the formation, de-excitation, and annihilation of antinucleonic exotic atoms, which provides robust rejection of positive nuclei and discrimination between antinucleus species.

The Astrophysical Journal 566, 604–616 (2002). p. 1
Where the paper says it

The GAPS program consists of several flights on NASA’s Antarctic long-duration balloon (LDB) platform. The unique strength of low-energy cosmic-ray d as a DM signal lies in the ultra-low astrophysical d background.

arXiv:astroph/0109463

[2] Hailey, C. J. An indirect search for dark matter using antideuterons: the GAPS experiment. p. 1

Where the paper says it

Abstract The General Antiparticle Spectrometer (GAPS) is an Antarctic stratospheric balloon mission designed to provide unmatched sensitivity to low-energy (< 0. 25 GeV/n) cosmic-ray antiprotons, antideuterons, and antihelium nuclei as signatures of dark matter.

New Journal of Physics 11, 105022 (2009)

[3] Hailey, C. J. et al. Antideuteron based dark matter search with GAPS: Current progress and future prospects. p. 6

Where the paper says it

Tracker The GAPS Tracker (Fig. 5) provides the stopping power and precision energy measurements required for a lowenergy antideuteron search.

Advances in Space Research 51, 290–296 (2013)

[4] Donato, F., Fornengo, N. & Salati, P. Antideuterons as a signature of supersymmetric dark matter. p. 1

Where the paper says it

25 GeV/n) cosmic-ray antideuterons (d). The discovery of cosmic-ray d by GAPS would be a smokinggun signature of new physics such as dark matter (DM) [4, 5, 6, 7, 8].

Phys. Rev. D 62, 043003 (2000). arXiv:hep-ph/9904481

[5] Donato, F., Fornengo, N. & Maurin, D. Antideuteron fluxes from dark matter annihilation in diffusion models. p. 1

Where the paper says it

25 GeV/n) cosmic-ray antiprotons, antideuterons, and antihelium nuclei as signatures of dark matter. The distinctive GAPS particle identification technique relies on measuring the energy loss along the track of an incoming antinucleus as it slows down and is captured into an exotic atom, and thendetecting the deexcitation X-rays and the nuclear annihilation products.

Phys. Rev. D 78, 043506 (2008). arXiv:0803. p. 0
Where the paper says it

edu (Field R. Rogers) arXiv:2604.

2640

[6] Donato, F., Korsmeier, M. & Di Mauro, M. Prescriptions on antiproton cross section data for precise theoretical antiproton flux predictions. p. 1

Where the paper says it

The discovery of cosmic-ray d by GAPS would be a smokinggun signature of new physics such as dark matter (DM) [4, 5, 6, 7, 8]. GAPS will also measure the cosmic-ray antiproton (p) spectrum in a lower energy regime than any other experiment [9, 10] and deliver unprecedented sensitivity to low-energy antihelium-3 nuclei (3He) [11].

Phys. Rev. D 96, 043007 (2017). arXiv:1704. p. 0
Where the paper says it

edu (Field R. Rogers) arXiv:2604.

03663

[7] von Doetinchem, P. et al. Cosmic-ray antinuclei as messengers of new physics: status and outlook for the new decade. p. 1

Where the paper says it

25 GeV/n) cosmic-ray antideuterons (d). The discovery of cosmic-ray d by GAPS would be a smokinggun signature of new physics such as dark matter (DM) [4, 5, 6, 7, 8].

Journal of Cosmology and Astroparticle Physics 2020, 035–035 (2020). p. 0
Where the paper says it

Moro 2, Rome, Italy. adState Key Laboratory of Dark Matter Physics, Key Laboratory for Particle Astrophysics and Cosmology (MoE), Shanghai Key Laboratory for Particle Physics and Cosmology, School of Physics and Astronomy, Shanghai Jiao Tong University, 800 Dongchuan Rd.

arXiv:2002. p. 0
Where the paper says it

edu (Field R. Rogers) arXiv:2604.

04163

[8] Aramaki, T. et al. Antideuteron sensitivity for the GAPS experiment. p. 1

Where the paper says it

The discovery of cosmic-ray d by GAPS would be a smokinggun signature of new physics such as dark matter (DM) [4, 5, 6, 7, 8]. GAPS will also measure the cosmic-ray antiproton (p) spectrum in a lower energy regime than any other experiment [9, 10] and deliver unprecedented sensitivity to low-energy antihelium-3 nuclei (3He) [11].

Astroparticle Physics 74, 6–13 (2016). p. 0
Where the paper says it

uUniversità di Pavia, I-27100 Pavia, Italy. vKavli Institute for Cosmological Physics, University of Chicago, 5640 S.

arXiv:1506. p. 0
Where the paper says it

edu (Field R. Rogers) arXiv:2604.

02513

[9] Aramaki, T. et al. Potential for precision measurement of low-energy antiprotons with GAPS for dark matter and primordial black hole physics. p. 1

Where the paper says it

Abstract The General Antiparticle Spectrometer (GAPS) is an Antarctic stratospheric balloon mission designed to provide unmatched sensitivity to low-energy (< 0. 25 GeV/n) cosmic-ray antiprotons, antideuterons, and antihelium nuclei as signatures of dark matter.

Astroparticle Physics 59, 12–17 (2014). p. 0
Where the paper says it

uUniversità di Pavia, I-27100 Pavia, Italy. vKavli Institute for Cosmological Physics, University of Chicago, 5640 S.

arXiv:1401. p. 0
Where the paper says it

edu (Field R. Rogers) arXiv:2604.

8245

[10] Rogers, F. et al. Sensitivity of the GAPS experiment to low-energy cosmic-ray antiprotons. p. 1

Where the paper says it

Abstract The General Antiparticle Spectrometer (GAPS) is an Antarctic stratospheric balloon mission designed to provide unmatched sensitivity to low-energy (< 0. 25 GeV/n) cosmic-ray antiprotons, antideuterons, and antihelium nuclei as signatures of dark matter.

Astroparticle Physics 145, 102791 (2023). p. 0
Where the paper says it

uUniversità di Pavia, I-27100 Pavia, Italy. vKavli Institute for Cosmological Physics, University of Chicago, 5640 S.

arXiv:2206. p. 0
Where the paper says it

edu (Field R. Rogers) arXiv:2604.

12991

[11] Saffold, N. et al. Cosmic antihelium-3 nuclei sensitivity of the GAPS experiment. p. 1

Where the paper says it

The discovery of cosmic-ray d by GAPS would be a smokinggun signature of new physics such as dark matter (DM) [4, 5, 6, 7, 8]. GAPS will also measure the cosmic-ray antiproton (p) spectrum in a lower energy regime than any other experiment [9, 10] and deliver unprecedented sensitivity to low-energy antihelium-3 nuclei (3He) [11].

Astroparticle Physics 130, 102580 (2021). p. 0
Where the paper says it

uUniversità di Pavia, I-27100 Pavia, Italy. vKavli Institute for Cosmological Physics, University of Chicago, 5640 S.

arXiv:2012. p. 0
Where the paper says it

edu (Field R. Rogers) arXiv:2604.

05834

[12] Sakai, K. et al. Search for antideuterons of cosmic origin using the bess-polar ii magnetic-rigidity spectrometer. p. 2

Where the paper says it

The abundant positive nuclei do not form exotic atoms and can thus be rejected. Compared to magnetic spectrometer experiments, such as BESS [20], PAMELA [21], and AMS-02 [22], this technique offers larger instrument acceptance, due to increased area and mass that can be dedicated to sensitive detectors; a lower energy range, due to decreased inactive material; and improved identification power for these rare-event signatures.

Phys. Rev. Lett. 132, 131001 (2024). arXiv:2507. p. 0
Where the paper says it

edu (Field R. Rogers) arXiv:2604.

p. 0
Where the paper says it

edu (Field R. Rogers) arXiv:2604.

p. 0
Where the paper says it

edu (Field R. Rogers) arXiv:2604.

07289

[13] Hailey, C. J. et al. Accelerator testing of the general antiparticle spectrometer; a novel approach to indirect dark matter detection. p. 1

Where the paper says it

Abstract The General Antiparticle Spectrometer (GAPS) is an Antarctic stratospheric balloon mission designed to provide unmatched sensitivity to low-energy (< 0. 25 GeV/n) cosmic-ray antiprotons, antideuterons, and antihelium nuclei as signatures of dark matter.

JCAP 2006, 007 (2006). arXiv:astro-ph/0509587

[14] Aramaki, T. et al. A measurement of atomic Xray yields in exotic atoms and implications for an antideuteron-based dark matter search. p. 1

Where the paper says it

The GAPS Antarctic flight program will provide nearly two orders-ofmagnitude improvement in d sensitivity compared to the current limits [8, 12], extending into an unprobed energy range where the significant DM signals would exist. GAPS uses a novel particle identification technique based on the formation, de-excitation, and annihilation of antinucleonic exotic atoms, which provides robust rejection of positive nuclei and discrimination between antinucleus species.

Astroparticle Physics 49, 52–62 (2013). p. 0
Where the paper says it

uUniversità di Pavia, I-27100 Pavia, Italy. vKavli Institute for Cosmological Physics, University of Chicago, 5640 S.

arXiv:1303. p. 0
Where the paper says it

edu (Field R. Rogers) arXiv:2604.

p. 0
Where the paper says it

edu (Field R. Rogers) arXiv:2604.

3871

[15] von Doetinchem, P. et al. The flight of the GAPS prototype experiment. p. 1

Where the paper says it

This detection technique was demonstrated in an antiproton beam at the KEK accelerator in 2004 [13, 14]. In 2012, a prototype GAPS balloon payload demonstrated critical hardware performance from a highaltitude platform [15, 16, 17, 18].

Astroparticle Physics 54, 93–109 (2014). p. 1
Where the paper says it

a combination of large instrument acceptance and long observation time for sensitivity to rare d fluxes of the order 10−6 [m2 s sr (GeV/n)]−1 at the top of the atmosphere, and 3. rejection of the positive nucleus backgrounds, which exceed the predicted d signals by a factor of > 109 in the energy band of interest, as well as robust discrimination between p and rare d or 3He signals.

arXiv:1307. p. 0
Where the paper says it

edu (Field R. Rogers) arXiv:2604.

3538

[16] Mognet, S. A. I. et al. The prototype GAPS (pGAPS) experiment. p. 1

Where the paper says it

This detection technique was demonstrated in an antiproton beam at the KEK accelerator in 2004 [13, 14]. In 2012, a prototype GAPS balloon payload demonstrated critical hardware performance from a highaltitude platform [15, 16, 17, 18].

Nuclear Instruments and Methods in Physics Research A 735, 24–38 (2014). p. 0
Where the paper says it

nTokai University, Hiratsuka, Kanagawa 259-1292, Japan. oPolar Environment Data Science Center, Joint Support-Center for Data Science Research (PEDSC/ROIS-DS), Research Organization of Information and Systems, Tachikawa, Tokyo 190-0014, Japan.

arXiv:1303.1615

[17] Fuke, H. et al. The pGAPS experiment: An engineering balloon flight of prototype GAPS. p. 1

Where the paper says it

This detection technique was demonstrated in an antiproton beam at the KEK accelerator in 2004 [13, 14]. In 2012, a prototype GAPS balloon payload demonstrated critical hardware performance from a highaltitude platform [15, 16, 17, 18].

Advances in Space Research 53, 1432–1437 (2014). p. 0
Where the paper says it

nTokai University, Hiratsuka, Kanagawa 259-1292, Japan. oPolar Environment Data Science Center, Joint Support-Center for Data Science Research (PEDSC/ROIS-DS), Research Organization of Information and Systems, Tachikawa, Tokyo 190-0014, Japan.

arXiv:80NSSC19K1425

[18] Fuke, H., Okazaki, S., Ogawa, H. & Miyazaki, Y. Balloon Flight Demonstration of an Oscillating Heat Pipe. p. 3

Where the paper says it

Basic functions of this unique system have been verified by environmental testing, a series of test flights, and numerical analyses [19, 25, 26, 27, 28]. The MCHP is a hybrid of an oscillating heat pipe (OHP, or pulsating heat pipe) and a thermosyphon.

Journal of Astronomical Instrumentation 6, 1740006–231 (2017). p. 1
Where the paper says it

We detail the design, integration, and commissioning of the payload prior to flight. Keywords: Balloon instrumentation, Scintillation detectors, Silicon detectors, Passive temperature control, Cosmic ray, Dark matter detector 1.

arXiv:2507.07289

[19] Okazaki, S. et al. Balloon flight test of a lowtemperature radiator. p. 1

Where the paper says it

In 2012, a prototype GAPS balloon payload demonstrated critical hardware performance from a highaltitude platform [15, 16, 17, 18]. Elements of the thermal system were demonstrated in two additional test flights [19].

Journal of Evolving Space Activities 2, 177 (2024)

[20] Abe, K. et al. Measurement of the Cosmic-Ray Antiproton Spectrum at Solar Minimum with a LongDuration Balloon Flight over Antarctica. p. 1

Where the paper says it

The discovery of cosmic-ray d by GAPS would be a smokinggun signature of new physics such as dark matter (DM) [4, 5, 6, 7, 8]. GAPS will also measure the cosmic-ray antiproton (p) spectrum in a lower energy regime than any other experiment [9, 10] and deliver unprecedented sensitivity to low-energy antihelium-3 nuclei (3He) [11].

Physics Review Letters 108, 051102 (2012). p. 1
Where the paper says it

This detection technique was demonstrated in an antiproton beam at the KEK accelerator in 2004 [13, 14]. In 2012, a prototype GAPS balloon payload demonstrated critical hardware performance from a highaltitude platform [15, 16, 17, 18].

arXiv:1107. p. 0
Where the paper says it

edu (Field R. Rogers) arXiv:2604.

6000

[21] Picozza, P. et al. Pamela – a payload for antimatter matter exploration and light-nuclei astrophysics. p. 2

Where the paper says it

The abundant positive nuclei do not form exotic atoms and can thus be rejected. Compared to magnetic spectrometer experiments, such as BESS [20], PAMELA [21], and AMS-02 [22], this technique offers larger instrument acceptance, due to increased area and mass that can be dedicated to sensitive detectors; a lower energy range, due to decreased inactive material; and improved identification power for these rare-event signatures.

Astroparticle Physics 27, 296–315 (2007). p. 0
Where the paper says it

uUniversità di Pavia, I-27100 Pavia, Italy. vKavli Institute for Cosmological Physics, University of Chicago, 5640 S.

arXiv:astroph/0608697

[22] Aguilar, M. et al. The alpha magnetic spectrometer (ams) on the international space station: Part ii — results from the first seven years. p. 2

Where the paper says it

The abundant positive nuclei do not form exotic atoms and can thus be rejected. Compared to magnetic spectrometer experiments, such as BESS [20], PAMELA [21], and AMS-02 [22], this technique offers larger instrument acceptance, due to increased area and mass that can be dedicated to sensitive detectors; a lower energy range, due to decreased inactive material; and improved identification power for these rare-event signatures.

Physics Reports 894, 1–116 (2021)

[23] Munini, R. et al. The antinucleus annihilation reconstruction algorithm of the gaps experiment. p. 1

Where the paper says it

25 GeV/n) cosmic-ray antiprotons, antideuterons, and antihelium nuclei as signatures of dark matter. The distinctive GAPS particle identification technique relies on measuring the energy loss along the track of an incoming antinucleus as it slows down and is captured into an exotic atom, and thendetecting the deexcitation X-rays and the nuclear annihilation products.

Astroparticle Physics 133, 102640 (2021). p. 0
Where the paper says it

uUniversità di Pavia, I-27100 Pavia, Italy. vKavli Institute for Cosmological Physics, University of Chicago, 5640 S.

arXiv:2109. p. 0
Where the paper says it

edu (Field R. Rogers) arXiv:2604.

00753

[24] Miles, D. M. Great observatories maturation: a review of nasa astrophysics development through suborbital rocket and balloon programs (2025). p. 1

Where the paper says it

A multi-loop capillary heat pipe system has been developed to maintain the tracker operating temperature with significant mass and power savings over a conventional pump-based system. The first GAPS science payload flew for 25 days during the 2025/26 NASA Antarctic balloon campaign.

arXiv:2507.07289

[25] Fuke, H. et al. Development of a cooling system for GAPS using oscillating heat pipe. p. 3

Where the paper says it

Basic functions of this unique system have been verified by environmental testing, a series of test flights, and numerical analyses [19, 25, 26, 27, 28]. The MCHP is a hybrid of an oscillating heat pipe (OHP, or pulsating heat pipe) and a thermosyphon.

Transactions JSASS Aerospace Technology, Japan 14, 17–26 (2016)

[26] Okazaki, S., Fuke, H., Miyazaki, Y. & Takahashi, N. Meter-scale multi-loop capillary heat pipe. p. 1

Where the paper says it

Together, these subsystems provide the velocity and energy resolution, stopping power, particle tracking, and X-ray identification necessary to distinguish rare antinucleus signals from the abundant positive-nucleus backgrounds, all within the constraints of a high-altitude mission. A multi-loop capillary heat pipe system has been developed to maintain the tracker operating temperature with significant mass and power savings over a conventional pump-based system.

Applied Thermal Engineering 141, 20–28 (2018)

[27] Fuke, H., Okazaki, S., Kondo, M., Kawachi, A. & Ogawa, H. Low-power, large-scale distributed hybrid thermal system to cool silicon detectors in the gaps instrument. p. 6

Where the paper says it

Custom Si(Li) Detectors A custom Si(Li) detector fabrication method was developed to satisfy the GAPS requirements. The large-area detector fabrication techniques, originally demonstrated inhouse [30] were further developed in partnership with Shimadzu Corp, a commercial producer of Si(Li) devices who offered large-scale facilities and trained technical staff for mass production.

In 2019 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 1–3 (2019)

[28] Fuke, H. et al. Operation concept of the gaps thermal control system. p. 5

Where the paper says it

Continuous battery voltage is also provided to a NASA/CSBF-provided science stack unit, which enables control of six critical PDU channels, including the onboard computer and network used to control the gondola, when the control computer itself is powered off. Gondola Control System The gondola control system manages the data acquisition activities of the Tracker and TOF subsystems, facilitates packaging and telemetry of both science and housekeeping data, and provides both automated and adjustable controls to ensure ongoing health of the instrument during remote operation.

Journal of Evolving Space Activities 2, 156 (2024)

Detector Design Details

The Tracker is composed of more than 1000 custom silicon strip detectors and a plastic scintillator time-of-flight (TOF) system instrumenting more than 40 m2 The Tracker provides a target capable of stopping d with energies up to 0.25 GeV/n, measuring energy depositions from 20 keV to 100 MeV The TOF provides a high-speed system trigger, particle velocity and energy deposition measurements, and further timing and position information for particle tracking The Tracker must provide a dynamic range spanning 20 keV to 100 MeV, with an energy resolution of < 5 keV (FWHM) below 100 keV and ≲ 10% in the MeV range

Thermal Management

A novel MCHP thermal system was developed to transport, with minimal mass, up to 300W of heat over horizontal and vertical distances of ≳1 m away from the Tracker to a radiator oriented towards space The MCHP is a hybrid of an oscillating heat pipe (OHP, or pulsating heat pipe) and a thermosyphon The radiator is composed of a 3.0 mm thick, 2. p. 3

Where the paper says it

The radiator is composed of a 3. 0 mm thick, 2.

3 m×4.

Green — the paper says it, and the page is printed. Red — no passage carries it, so treat that sentence as unverified. The same check runs on your own text: check a summary against its source, $5.

Improvements for AI systems

  1. Improved Particle Identification Capability: The system can distinguish between antinucleus species by the combination of its incident energy-loss patterns and the resulting X-ray energies and hadron multiplicity, which allows for robust rejection of positive nuclei and discrimination between p and rare d or 3He signals.

  2. Enhanced Sensitivity to Low Energy Signals: The improved system can detect low energy cosmic ray antideuterons by extending sensitivity to an unprobed energy range where the significant DM signals would exist compared to current limits, providing nearly two orders-of-magnitude improvement in d sensitivity.

  3. Precise Tracking and Vertex Reconstruction: The Tracker provides a capability for resolving interaction vertices to within ≲ 1 cm, which is sufficient for scientific goals, and it measures energy depositions from 20 keV to 100 MeV with an energy resolution of "< 5 keV (FWHM) below 100 keV."

  4. Robust Background Rejection: The system rejects positive nuclei backgrounds by relying on the fact that they do not form exotic atoms and can thus be rejected, achieving a rejection factor "of > 109 in the energy band of interest."

  5. High-Speed Event Triggering: The TOF system delivers a system trigger generated within 400 ns of a particle interaction, enabling the assembly of data packets into a TOF event structure, which is crucial for timely analysis.

  6. Advanced Data Assembly and Classification: The online software can perform an online classification to flag antinucleus-like events for priority transmission based on variables like the multiplicity and total energy deposition of Tracker hits above a programmable software energy threshold.

Abstract

The General Antiparticle Spectrometer (GAPS) is an Antarctic stratospheric balloon mission designed to provide unmatched sensitivity to low-energy (< 0.25 GeV/n) cosmic-ray antiprotons, antideuterons, and antihelium nuclei as signatures of dark matter. The distinctive GAPS particle identification technique relies on measuring the energy loss along the track of an incoming antinucleus as it slows down and is captured into an exotic atom, and then detecting the de-excitation X-rays and the nuclear annihilation products. This measurement is realized using a Tracker composed of more than 1000 custom silicon strip detectors and a plastic scintillator time-of-flight (TOF) system instrumenting more than 40 m squared. Together, these subsystems provide the velocity and energy resolution, stopping power, particle tracking, and X-ray identification necessary to distinguish rare antinucleus signals from the abundant positive-nucleus backgrounds, all within the constraints of a high-altitude mission. A multi-loop capillary heat pipe system has been developed to maintain the tracker operating temperature with significant mass and power savings over a conventional pump-based system. The first GAPS science payload flew for 25 days during the 2025/26 NASA Antarctic balloon campaign. We detail the design, integration, and commissioning of the payload prior to flight.

Sources

Related papers