Electromagnetic Shower Reconstruction and Identification in FASER's Emulsion Detector for LHC Forward Neutrino Measurements
Listen
Radio episode about this paper
Transcript
Introduction to the show: ident: High Energy Physics: Experiment. The day in high-energy experiment: detectors, searches and limits.
Kai: We're looking at the paper: "Electromagnetic Shower Reconstruction and Identification in FASER's Emulsion Detector for LHC Forward Neutrino Measurements".
Mira: Here's the gist of the paper. Electromagnetic shower reconstruction and identification methods were developed for the FASERnu emulsion detector using test-beam data to validate a framework for electron neutrino identification at the LHC The reconstruction employs a clustering-based algorithm without energy-dependent tuning to determine shower axes The multi-level identification chain comprising track pre-selection, a cut-based selection, and a BDT classifier achieves combined background rejection rates of 99.99% (100 GeV) and 99.94% (200 GeV) The method reaches total reconstruction and identification efficiencies of 58.9% (100 GeV) and 70.8% (200 GeV) evaluated from simulated samples.
Kai: Experimental Setup and Data Quality Emulsion modules were exposed to electron and muon beams at CERN SPS H4 beamline in 2023, providing mono-energetic electron samples at 100 GeV and 200 GeV.
Mira: The experimental setup is shown in Figure 2 The target exposure density was approximately 8 electrons/cm squared.
Kai: Beam conditions achieved were characterized by an electron purity of >80% for the 100 GeV module and >90% for the 200 GeV module.
Title and authors: Kai: This paper's title is "Electromagnetic Shower Reconstruction and Identification in FASER's Emulsion Detector for LHC Forward Neutrino Measurements". It tells you exactly what the paper is about.
Mira: It’s essentially detailing the methods they developed for reconstructing and identifying those electromagnetic showers using their emulsion detector setup at FASER, which is key for studying neutrino interactions at the LHC.
Lev: What does that mean in plain terms? They are showing how to take raw tracks seen in the emulsion and turn them into a usable signal about whether a particle was an electron neutrino or something else >
Kai: Right. The core of it is the reconstruction pipeline they use, which involves clustering-based algorithms and multi-level identification steps to separate background from signal >
Mira: They’re highlighting that this framework works by determining shower axes without needing to tune parameters specifically for the energy of the shower, which is a big deal for flexibility >
Lev: So it’s about creating a general method that should be applicable across different energy scales at the LHC, which is what we need when scaling up detectors >
Kai: Precisely. They are showing how to use adaptive parameter selection based on local segment density during the reconstruction phase to handle those variations without prior knowledge of the shower energy >
Mira: That approach sounds flexible. It means that if you get a track with a very dense region locally, the algorithm adjusts its parameters automatically, instead of needing a specific tuning for that high-density situation >
Lev: But how much does that local density actually vary when you're looking at these forward showers? Is it stable enough to rely on this adaptation >
Kai: The paper doesn't detail the exact variation of local density across the whole volume, but they show that DBSCAN is applied independently to segments on each plate using their 2D spatial coordinates X and Y to group points in high-density regions > <ref:2606.18517#pg1>
Mira: So they’re relying on spatial clustering in a specific way, not on some energy-dependent tuning based on a calculated energy input for the shower >
Lev: That’s what I need to know. When we build real hardware, we need stability. If the clustering behavior changes drastically depending on the local environment, that makes things much harder to control >
Kai: They also use linear regression to determine the initial shower axis by fitting just the first three segments of each primary track independently in both Z-X and Z-Y projection planes >
Mira: That's a straightforward way to establish a starting point for the reconstruction, using just the very beginning of those tracks to define where they’re going >
Lev: So they don't need to wait for the whole shower to develop before they can start tracking its direction, which is good because it speeds things up >
Kai: They then define a preliminary cylindrical search volume around that initial axis, with a radius of one hundred µm and a length of eight cm >
Mira: That cylinder is where the next step happens: applying DBSCAN independently to segments on each plate using their X and Y coordinates to group points in high-density regions within that volume >
Lev: So they’re essentially creating localized groups of data based purely on how dense the points are, without needing an energy model to define what "dense" means >
Kai: That's the key feature they emphasize, which is that adaptive parameter selection is based on local segment density without requiring prior knowledge of the shower energy >
Mira: So, to summarize this section, they’re presenting a method for reconstructing shower axes and identifying them using a clustering algorithm that adapts locally to the data structure itself >
Lev: It sounds like they’ve solved one of the main hurdles in these emulsion experiments: getting robust geometry estimation without relying on complex energy modeling assumptions >
Kai: Exactly. It’s about making the reconstruction more self-sufficient when you don're dealing with a broad range of possible physics outcomes >
The paper's summary: Kai: Okay, so we’ve talked about the reconstruction method, now let’s look at what they actually found in terms of performance. This is about the results section of "Electromagnetic Shower Reconstruction and Identification in FASER's Emulsion Detector for LHC Forward Neutrino Measurements".
Mira: They are showing that their multi-level identification chain, which goes from track pre-selection to a cut-based selection and then the BDT classifier, yields very high background rejection rates.
Lev: What kind of numbers are we talking about here? Are we talking about something like ninety percent or ninety-five percent rejection?
Kai: They report combined background rejection rates of ninety-nine point nine nine percent at one hundred GeV and two hundred GeV, and then a slightly lower rate of ninety-nine point eight four percent at the higher energy > <ref:2606.18517#pg3>
Mira: That's extremely high, which is what you want when you are trying to distinguish genuine EM showers from the dominant muon background that mimics them in these detectors >
Lev: So they managed to keep that high rejection while still achieving decent signal efficiency, otherwise we wouldn't get much data to analyze later >
Kai: They also report the total reconstruction and identification efficiencies for simulated samples, showing fifty-eight point nine percent at one hundred GeV and seventy point eight percent at two hundred GeV >
Mira: So they’re saying that even with this high rejection, you still manage to pull out a significant fraction of the true signal that we care about >
Lev: And what about the energy measurement itself? How accurate are they when estimating the energy of these showers using just the segments?
Kai: They use the total number of segments across all plates in a reconstructed shower, Ntotal, as their estimator for calorimetric energy >
Mira: When they look at those numbers, relative biases are +zero point six percent at one hundred GeV and-zero point eight percent at two hundred GeV with resolutions of twenty-five point four percent and twenty-two point six percent, respectively >
Lev: That means the energy resolution is pretty good for a calorimetric estimate, but those biases are small enough that they’re not going to ruin our analysis significantly, right?
Kai: They also point out that systematic uncertainties on the reconstructed energy are dominated by single-film efficiency variations >
Mira: So it’s telling us where the detector imperfections are having the biggest impact on our energy estimates, which is good for understanding what to fix next >
The paper's improvements: Lev: Now that we know how they do it, let’s talk about what they suggest as improvements over previous work. What’s the actual upgrade path?
Kai: They refined the reconstruction algorithm by combining adaptive DBSCAN clustering, sequential centroid validation with a sixty µm deviation threshold, and Huber robust fitting to determine shower axes > <ref:2606.18517#pg3>
Mira: That combination of techniques is what allows them to get those reliable axes without relying on energy-dependent parameter tuning, which is a big methodological improvement >
Lev: So they’re essentially saying that you can get this robust geometric reconstruction using these specific mathematical tools instead of whatever complex model was used before >
Kai: They also mentioned that the ratio-based and angular variables are designed to remain stable across the broad FASERnu energy range, which is what enables a single trained classifier to be applied at fifty GeV and above without needing any retuning >
Mira: That's really practical. If you can have one classifier that works for both one hundred GeV and two hundred GeV, you save a ton of work on the analysis side > <ref:2606.18517#pg3>
Lev: It simplifies the downstream analysis significantly, but what about the limitations they explicitly state in this paper? Where does it stop working?
Kai: They do flag that their position resolution is evaluated with a track-extrapolation method for each film, and most plates show resolutions of zero point five to one point five µm >
Mira: And they also mention that some films get degraded up to about three µm because of things like variations in film alignment quality, emulsion distortions, and scanning conditions > <ref:2606.18517#pg1>
Lev: So the limitation isn't just the resolution itself; it’s the physical quality of the film setup which affects how well we can measure those positions >
Kai: And for angular resolution, they use a segment-difference method to evaluate track direction, and they note that this resolution is systematically larger in the horizontal projection in both modules because of the elliptical angular distribution of the test beam >
Mira: So to summarize these improvements, it’s about making the reconstruction more robust using adaptive clustering and robust fitting without needing energy-dependent tuning for axis determination >
Lev: It sounds like they’ve put together a solid set of tools for a broad energy range, but we still have to deal with the physical limitations of the emulsion itself >
Conclusion: Kai: So wrapping up on this paper, the main implication is that this detailed work establishes a validated framework for electron neutrino identification at the LHC using FASERnu data >
Mira: They’re essentially showing that their specific reconstruction and identification chain achieves background rejection rates of ninety-nine point nine nine percent at one hundred GeV and two hundred GeV > <ref:2606.18517#pg3>
Lev: That high level of rejection means we have a very clean way to search for the physics they are looking for in the forward region >
Kai: And they’ve shown that energy reconstruction using total reconstructed segments yields relative biases of +zero point six percent at one hundred GeV and-zero point eight percent at two hundred GeV >
Mira: So, overall, this work provides a validated pipeline for identifying these showers in the FASERnu detector for LHC forward neutrino measurements >
Lev: It’s a solid tool to use as we plan out the next phases of experimental design and data analysis based on what they’ve shown here >
Kai: This paper, "Electromagnetic Shower Reconstruction and Identification in FASER's Emulsion Detector for LHC Forward Neutrino Measurements", is a piece of work that shows how careful methodology can lead to solid results >
Mira: It validates the reconstruction and identification pipeline for electron neutrino identification at the LHC using test-beam data >
Lev: We’ll keep this as a useful reference when we start designing detectors that need to handle these types of challenges >
Roshan Mammen Abraham, Xiaocong Ai, Saul Alonso Monsalve, John Anders, Emma Kate Anderson, Akitaka Ariga, È Tomoko Ariga, f Jeremy Atkinson, Ɠ Florian U. Bernlochner, ᐫ Jianming Bian, Tobias Boeckh, Eli Bornand, Jamie Boyd, Lydia Brenner, Angela Burger, Franck Cadoux, Roberto Cardella, David W. Casper, Charlotte Cavanagh, Shiyang Chen, Xin Chen, Xing Cheng, Dhruv Chouhan, Andrea Coccaro, Fabio Cufino, Stephane Débieux Ansh Desai, œ Sergey Dmitrievsky, Radu Dobre, Monica D’Onofrio, Sinead Eley, Yannick Favre, Jonathan L. Feng, Carlo Alberto Fenoglio, Didier Ferrere, Max Fieg, Wissal Filali Elena Firu Haruhi Fujimori Edward Galantay Stephen Gibson Yuri Gornushkin Yotam Granov Jinjing Gu Carl Gwilliam Elie Hammou Daiki Hayakawa Michael Holzbock Shih-Chieh Hsu Zhen Hu Lekai Yao Daichi Yoshikawa Shunliang Zhang Yuxuan Zhang Xingyu Zhao, Eli Welch, Aaron White, Monika Wielers, Benjamin James Wilson Zhongyi Wu, Yue Xu Heng Yang Yi Liu Jiaxi Liu Jinfeng Liu Yi Liu Margaret S. Lutz Joern Mahlstedt Toni Mäkelä Yasuhiro Maruya Anna Mascellani Lawson McCoy Josh McFayden Andrea Pizarro Medina Hiroaki Menjo Toshiyuki Nakano Laurie Nevay Yuma Ohara Ken Ohashi Hidetoshi Otono Lorenzo Paolozzi Annabelle Parry Pawan Pawan Brian Petersen Titi Preda Markus Prim Junkai Qin Michaela Queitsch-Maitland Hiroki Rokujo André Rubbia Osamu Sato Paola Scampoli Kristof Schmieden Matthias Schott Cristiano Sebastiani Anna Sfyrla Davide Sgalaberna Mansoora Shamim Yosuke Takubo Kakeru Tanaka Noshin Tarannum Simon Thor Eric Torrence Serhan Tufanli Oscar Ivan Valdes Martinez Svetlana Vasina Emanuele Villa Benedikt Vormwald Chi Wang Yuxiao Wang, Eli Welch, Aaron White, Monika Wielers
Department of Physics and Astronomy, University of California, Irvine · School of Physics, Zhengzhou University · Institute for Particle Physics, ETH Zurich · University of Liverpool · É CERN
hep-ex
Submitted: 2026-06-16
Updated: 2026-08-24
Comments: 23 pages, 18 figures
Journal ref: JINST 21 (2026) P10044
DOI: 10.1088/1748-0221/21/10/P10044
License: http://creativecommons.org/licenses/by/4.0/
Importance score: 87/100
The gist: Electromagnetic shower reconstruction and identification methods were developed for the FASERnu emulsion detector using test-beam data to validate a framework for electron neutrino identification at…
Key concepts
- Adaptive Clustering
- This is the technique used to find the shower axis. Instead of setting fixed parameters based on expected energy, the algorithm adjusts its search volume and grouping method based on how densely packed the actual segments are locally. This allows for accurate reconstruction regardless of whether a shower is at 100 GeV or 200 GeV.
- Multi-level Identification Chain
- This is a three-step process to separate genuine showers from background noise (like muons). It starts with filtering tracks, then uses simple cuts to remove most remaining muons, and finally employs a sophisticated Boosted Decision Tree (BDT) classifier. This layered approach ensures very high purity while keeping the signal efficiency high.
- BDT Classifier Features
- The BDT classifier distinguishes showers by analyzing ten specific shape variables: six related to the shower's length (longitudinal), three related to its width (transverse), clustering metrics, and one angular variable. These features are chosen because they remain stable across different energies, allowing one trained model to work effectively for 50 GeV and above.
- Energy Reconstruction via Segments
- The total number of reconstructed segments ($N_{total}$) in the shower is used as an estimator for its energy. This method provides relative energy biases that are predictable based on the beam energy (e.g., +0.6% at 100 GeV). The resolution of this estimate is relatively high, allowing for calibrated measurements despite detector imperfections.
Terminology
Summary
Electromagnetic shower reconstruction and identification methods were developed for the FASERnu emulsion detector using test-beam data to validate a framework for electron neutrino identification at the LHC
The reconstruction employs a clustering-based algorithm without energy-dependent tuning to determine shower axes The multi-level identification chain comprising track pre-selection, a cut-based selection, and a BDT classifier achieves combined background rejection rates of 99.99% (100 GeV) and 99. p. 1 17Institute of Space Science—INFLPR Subsidiary, Bucharest, Romania
18Theoretical Physics Division, Fermi National Accelerator Laboratory, Batavia, IL 60510, USA
19Royal Holloway, University of London, Egham, TW20 0EX, United Kingdom
20Department of Physics and Astronomy,
Technion—Israel Institute of Technology, Haifa 32000, Israel
21Department of Physics, University of Washington,
PO Box 351560, Seattle, WA 98195-1460, USA
22Department of Particle Physics and Astrophysics,
Weizmann Institute of Science, Rehovot 76100, Israel
23Department of Physics & Astronomy, University of Sussex,
Sussex House, Falmer, Brighton, BN1 9RH, United Kingdom
24Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8602, Japan
25University of Manchester, School of Physics and Astronomy,
Schuster Building, Oxford Rd, Manchester M13 9PL, United Kingdom
26Dipartimento di Fisica “Ettore Pancini”, Universit`a di Napoli Federico II,
Complesso Universitario di Monte S. Angelo, I-80126 Napoli, Italy
27National Institute of Technology (KOSEN), Niihama College,
7-1, Yakumo-cho Niihama, 792-0805 Ehime, Japan
28Particle Physics Department, STFC Rutherford Appleton Laboratory,
Harwell Campus, Didcot, OX11 0QX, United Kingdom
We present methods for electromagnetic shower reconstruction and identification in the
FASERν emulsion detector using 100 GeV and 200 GeV electron test-beam data from the
CERN SPS H4 beamline. 94% (200 GeV). The method reaches
total reconstruction and identification efficiencies of 58. 17Institute of Space Science—INFLPR Subsidiary, Bucharest, Romania
18Theoretical Physics Division, Fermi National Accelerator Laboratory, Batavia, IL 60510, USA
19Royal Holloway, University of London, Egham, TW20 0EX, United Kingdom
20Department of Physics and Astronomy,
Technion—Israel Institute of Technology, Haifa 32000, Israel
21Department of Physics, University of Washington,
PO Box 351560, Seattle, WA 98195-1460, USA
22Department of Particle Physics and Astrophysics,
Weizmann Institute of Science, Rehovot 76100, Israel
23Department of Physics & Astronomy, University of Sussex,
Sussex House, Falmer, Brighton, BN1 9RH, United Kingdom
24Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8602, Japan
25University of Manchester, School of Physics and Astronomy,
Schuster Building, Oxford Rd, Manchester M13 9PL, United Kingdom
26Dipartimento di Fisica “Ettore Pancini”, Universit`a di Napoli Federico II,
Complesso Universitario di Monte S. Angelo, I-80126 Napoli, Italy
27National Institute of Technology (KOSEN), Niihama College,
7-1, Yakumo-cho Niihama, 792-0805 Ehime, Japan
28Particle Physics Department, STFC Rutherford Appleton Laboratory,
Harwell Campus, Didcot, OX11 0QX, United Kingdom
We present methods for electromagnetic shower reconstruction and identification in the
FASERν emulsion detector using 100 GeV and 200 GeV electron test-beam data from the
CERN SPS H4 beamline. 9% (100 GeV) and 70. 8% (200 GeV)
evaluated from simulated samples.Where the paper says it
Where the paper says it
Where the paper says it
Where the paper says it
Experimental Setup and Data Quality
Emulsion modules were exposed to electron and muon beams at CERN SPS H4 beamline in 2023, providing mono-energetic electron samples at 100 GeV and 200 GeV. The experimental setup is shown in Figure 2 The target exposure density was approximately 8 electrons/cm squared. p. 4 5
• 200 GeV (module T1101): 40–60 particles per spill, electron purity >90%. The target exposure density was approximately 8 electrons/cm2
. A right-handed coordinate system is adopted throughout this paper: the Z-axis points along
the beam direction, X is horizontal transverse, and Y is vertical transverse. The achieved beam
conditions were:
• 100 GeV (module T1202): 40–50 particles per spill, electron purity >80%;Where the paper says it
Where the paper says it
Shower Reconstruction Pipeline
The reconstruction begins with tracks originating from the first emulsion plate, and the initial shower axis is determined by fitting the first three segments of each primary track independently in the Z-X and Z-Y projection planes using linear regression. A preliminary cylindrical search volume is then defined around the initial axis, with radius 100 µm and length 8 cm. p. 7 8 mrad) while minimizing deflections from early
shower development and multiple scattering; using fewer plates gives insufficient constraints, while
more plates increasingly biases the fit through shower scattering. A preliminary cylindrical search volume is then defined around the initial axis, with radius
100 µm and length 8 cm (approximately 18 radiation lengths, spanning 56 plates). Within the preliminary cylindrical volume, DBSCAN is applied independently to segments on
each plate using their 2D spatial coordinates (X, Y). It groups points in high-density regions while
classifying isolated points as noise, making it well-suited for separating the dense EM shower core
from background tracks and peripheral shower particles. The algorithm requires two input parameters: a neighbourhood radius ε, within which points are
considered neighbours, and a minimum cluster size Nmin, the minimum number of neighbouring
points required to form a cluster. The key feature of our implementation is adaptive parameter selection based on local segment
density, without requiring prior knowledge of the shower energy.Where the paper says it
Where the paper says it
Where the paper says it
Identification Strategy and Performance
A multi-level identification strategy is employed to distinguish genuine EM showers from the dominant muon background. After shower reconstruction, a cut-based selection (Loose ID) removes the bulk of remaining muon tracks that mimic shower topologies through accidental segment accumulation in the cylindrical volume. p. 5 SHOWER RECONSTRUCTION AND IDENTIFICATION
Figure 3 provides an overview of the complete analysis chain. The pipeline proceeds in three
stages: pre-selection applies track-level quality cuts to reject obvious muon backgrounds; shower
reconstruction uses adaptive DBSCAN (Density-Based Spatial Clustering of Applications with
Noise) clustering [20] and Huber robust axis fitting to collect shower segments within a cylindrical
volume; identification applies cut-based Loose ID followed by BDT-based Medium ID to distinguish
genuine electrons from residual backgrounds. SHOWER RECONSTRUCTION AND IDENTIFICATION
Figure 3 provides an overview of the complete analysis chain. The pipeline proceeds in three
stages: pre-selection applies track-level quality cuts to reject obvious muon backgrounds; shower
reconstruction uses adaptive DBSCAN (Density-Based Spatial Clustering of Applications with
Noise) clustering [20] and Huber robust axis fitting to collect shower segments within a cylindrical
volume; identification applies cut-based Loose ID followed by BDT-based Medium ID to distinguish
genuine electrons from residual backgrounds. The reconstruction employs a clustering-based algorithm without
energy-dependent tuning to determine shower axes. A multi-level identification chain comprising track pre-selection, a cut-based selection, and a BDT classifier achieves combined
background rejection rates of 99. The same visual confirmation is applied when measuring muon background rejection
rates in test beam data (Section 4), where tracks surviving the identification chain are inspected to
verify whether they are genuine muon backgrounds or misidentified EM showers. Both selections
are performed by trained scanners familiar with emulsion event topologies.Where the paper says it
Where the paper says it
Where the paper says it
Where the paper says it
Energy Reconstruction and Uncertainties
The total number of segments across all plates in the reconstructed shower, Ntotal, is used as the calorimetric energy estimator. Energy reconstruction using the total number of reconstructed segments yields relative biases of +0. p. 1 8% (200 GeV)
evaluated from simulated samples. Energy reconstruction using the total number of reconstructed segments as the calorimetric estimator yields relative biases of +0. 17Institute of Space Science—INFLPR Subsidiary, Bucharest, Romania
18Theoretical Physics Division, Fermi National Accelerator Laboratory, Batavia, IL 60510, USA
19Royal Holloway, University of London, Egham, TW20 0EX, United Kingdom
20Department of Physics and Astronomy,
Technion—Israel Institute of Technology, Haifa 32000, Israel
21Department of Physics, University of Washington,
PO Box 351560, Seattle, WA 98195-1460, USA
22Department of Particle Physics and Astrophysics,
Weizmann Institute of Science, Rehovot 76100, Israel
23Department of Physics & Astronomy, University of Sussex,
Sussex House, Falmer, Brighton, BN1 9RH, United Kingdom
24Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8602, Japan
25University of Manchester, School of Physics and Astronomy,
Schuster Building, Oxford Rd, Manchester M13 9PL, United Kingdom
26Dipartimento di Fisica “Ettore Pancini”, Universit`a di Napoli Federico II,
Complesso Universitario di Monte S. Angelo, I-80126 Napoli, Italy
27National Institute of Technology (KOSEN), Niihama College,
7-1, Yakumo-cho Niihama, 792-0805 Ehime, Japan
28Particle Physics Department, STFC Rutherford Appleton Laboratory,
Harwell Campus, Didcot, OX11 0QX, United Kingdom
We present methods for electromagnetic shower reconstruction and identification in the
FASERν emulsion detector using 100 GeV and 200 GeV electron test-beam data from the
CERN SPS H4 beamline. 6% (100 GeV)
and −0. 8% (200 GeV), with resolutions of 25. 8% (200 GeV), with resolutions of 25. 6%, respectively. 6%, respectively. Systematic uncertainties on the energy reconstruction are dominated by variations in emulsion film detection
efficiency, with totals of +10. 8 GeV, while the upper bound removes muon tracks traversing most of the
detector. The different upper bounds at the two energies reflect a module-dependent tracking
quality effect and are determined by MC simulation samples. 8 GeV, while the upper bound removes muon tracks traversing most of the
detector. The different upper bounds at the two energies reflect a module-dependent tracking
quality effect and are determined by MC simulation samples.Where the paper says it
Where the paper says it
Where the paper says it
Where the paper says it
Where the paper says it
Where the paper says it
Where the paper says it
Conclusion
The reconstruction algorithm combines adaptive DBSCAN clustering, sequential centroid validation with a 60 µm deviation threshold, and Huber robust fitting to determine shower axes without energy-dependent parameter tuning. A multi-level identification chain comprising track pre-selection, cut-based Loose ID, and BDTbased Medium ID achieves combined background rejection rates of 99. p. 1 The reconstruction employs a clustering-based algorithm without
energy-dependent tuning to determine shower axes. A multi-level identification chain comprising track pre-selection, a cut-based selection, and a BDT classifier achieves combined
background rejection rates of 99. 17Institute of Space Science—INFLPR Subsidiary, Bucharest, Romania
18Theoretical Physics Division, Fermi National Accelerator Laboratory, Batavia, IL 60510, USA
19Royal Holloway, University of London, Egham, TW20 0EX, United Kingdom
20Department of Physics and Astronomy,
Technion—Israel Institute of Technology, Haifa 32000, Israel
21Department of Physics, University of Washington,
PO Box 351560, Seattle, WA 98195-1460, USA
22Department of Particle Physics and Astrophysics,
Weizmann Institute of Science, Rehovot 76100, Israel
23Department of Physics & Astronomy, University of Sussex,
Sussex House, Falmer, Brighton, BN1 9RH, United Kingdom
24Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8602, Japan
25University of Manchester, School of Physics and Astronomy,
Schuster Building, Oxford Rd, Manchester M13 9PL, United Kingdom
26Dipartimento di Fisica “Ettore Pancini”, Universit`a di Napoli Federico II,
Complesso Universitario di Monte S. Angelo, I-80126 Napoli, Italy
27National Institute of Technology (KOSEN), Niihama College,
7-1, Yakumo-cho Niihama, 792-0805 Ehime, Japan
28Particle Physics Department, STFC Rutherford Appleton Laboratory,
Harwell Campus, Didcot, OX11 0QX, United Kingdom
We present methods for electromagnetic shower reconstruction and identification in the
FASERν emulsion detector using 100 GeV and 200 GeV electron test-beam data from the
CERN SPS H4 beamline. 17Institute of Space Science—INFLPR Subsidiary, Bucharest, Romania
18Theoretical Physics Division, Fermi National Accelerator Laboratory, Batavia, IL 60510, USA
19Royal Holloway, University of London, Egham, TW20 0EX, United Kingdom
20Department of Physics and Astronomy,
Technion—Israel Institute of Technology, Haifa 32000, Israel
21Department of Physics, University of Washington,
PO Box 351560, Seattle, WA 98195-1460, USA
22Department of Particle Physics and Astrophysics,
Weizmann Institute of Science, Rehovot 76100, Israel
23Department of Physics & Astronomy, University of Sussex,
Sussex House, Falmer, Brighton, BN1 9RH, United Kingdom
24Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8602, Japan
25University of Manchester, School of Physics and Astronomy,
Schuster Building, Oxford Rd, Manchester M13 9PL, United Kingdom
26Dipartimento di Fisica “Ettore Pancini”, Universit`a di Napoli Federico II,
Complesso Universitario di Monte S. Angelo, I-80126 Napoli, Italy
27National Institute of Technology (KOSEN), Niihama College,
7-1, Yakumo-cho Niihama, 792-0805 Ehime, Japan
28Particle Physics Department, STFC Rutherford Appleton Laboratory,
Harwell Campus, Didcot, OX11 0QX, United Kingdom
We present methods for electromagnetic shower reconstruction and identification in the
FASERν emulsion detector using 100 GeV and 200 GeV electron test-beam data from the
CERN SPS H4 beamline. The reconstruction employs a clustering-based algorithm without
energy-dependent tuning to determine shower axes. A multi-level identification chain comprising track pre-selection, a cut-based selection, and a BDT classifier achieves combined
background rejection rates of 99. 8% (200 GeV)
evaluated from simulated samples. Energy reconstruction using the total number of reconstructed segments as the calorimetric estimator yields relative biases of +0. 17Institute of Space Science—INFLPR Subsidiary, Bucharest, Romania
18Theoretical Physics Division, Fermi National Accelerator Laboratory, Batavia, IL 60510, USA
19Royal Holloway, University of London, Egham, TW20 0EX, United Kingdom
20Department of Physics and Astronomy,
Technion—Israel Institute of Technology, Haifa 32000, Israel
21Department of Physics, University of Washington,
PO Box 351560, Seattle, WA 98195-1460, USA
22Department of Particle Physics and Astrophysics,
Weizmann Institute of Science, Rehovot 76100, Israel
23Department of Physics & Astronomy, University of Sussex,
Sussex House, Falmer, Brighton, BN1 9RH, United Kingdom
24Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8602, Japan
25University of Manchester, School of Physics and Astronomy,
Schuster Building, Oxford Rd, Manchester M13 9PL, United Kingdom
26Dipartimento di Fisica “Ettore Pancini”, Universit`a di Napoli Federico II,
Complesso Universitario di Monte S. Angelo, I-80126 Napoli, Italy
27National Institute of Technology (KOSEN), Niihama College,
7-1, Yakumo-cho Niihama, 792-0805 Ehime, Japan
28Particle Physics Department, STFC Rutherford Appleton Laboratory,
Harwell Campus, Didcot, OX11 0QX, United Kingdom
We present methods for electromagnetic shower reconstruction and identification in the
FASERν emulsion detector using 100 GeV and 200 GeV electron test-beam data from the
CERN SPS H4 beamline. 6% (100 GeV)
and −0. 8% (200 GeV), with resolutions of 25. 6%, respectively. Systematic uncertainties on the energy reconstruction are dominated by variations in emulsion film detection
efficiency, with totals of +10. For each selected cluster, the
spatial centroid is computed:
(X, ¯ Y , ¯ Z¯) = 1
Ncluster
N
Xcluster
i=1
(Xi
, Yi
, Zi) (4)
Figure 5 shows an example of DBSCAN clustering on a shower from the 200 GeV electron MC
sample. To suppress contamination from peripheral shower particles that may create spurious centroids
far from the true shower axis, a sequential validation procedure is applied before the final axis fit. A right-handed coordinate system is adopted throughout this paper: the Z-axis points along
the beam direction, X is horizontal transverse, and Y is vertical transverse. The achieved beam
conditions were:
• 100 GeV (module T1202): 40–50 particles per spill, electron purity >80%;Where the paper says it
Where the paper says it
Where the paper says it
Where the paper says it
Where the paper says it
Where the paper says it
Where the paper says it
Where the paper says it
Where the paper says it
Where the paper says it
Acknowledgments
We thank the CERN EP department for the refurbishment of the CERN dark room, used for the preparation and development of the FASERnu emulsion We thank Saya Yamamoto for supporting the preparation of emulsion films We thank the CERN beam group, especially Nikolaos Charitonidis, for excellent beam operation at the SPS-H4 beamline. This work was supported in part by Heising-Simons Foundation Grant Nos. 2019-1179 and 2020-1840 Simons Foundation Grant No. 623683, JSPS KAKENHI Grant Nos. 19H01909, 22H01233, 20K23373, 23H00103, 20H01919, and 21H00082. The joint research program of the Institute of Materials and Systems for Sustainability, ERC Consolidator Grant No. p. 6 After track reconnection and pre-selection, approximately 29% of tracks
originating from the first plate survive at both energies in test-beam data. Figure 4 shows the joint distributions of θs and nseg for electron MC and test-beam data in
both modules: muon tracks populate the region of large nseg and small θs, well separated from the
short, large-scattering tracks characteristic of EM showers. 2
10D´epartement de Physique Nucl´eaire et Corpusculaire,
University of Geneva, CH-1211 Geneva 4, Switzerland
11Nikhef National Institute for Subatomic Physics,
Science Park 105, 1098 XG Amsterdam, Netherlands
12L2IT, Universit´e de Toulouse, CNRS/IN2P3, UPS, Toulouse, France
13Department of Physics, Tsinghua University, Beijing, China
14INFN Sezione di Genova, Via Dodecaneso, 33–16146, Genova, Italy
15University of Oregon, Eugene, OR 97403, USA
16Affiliated with an international laboratory covered by a cooperation agreement with CERN. 17Institute of Space Science—INFLPR Subsidiary, Bucharest, Romania
18Theoretical Physics Division, Fermi National Accelerator Laboratory, Batavia, IL 60510, USA
19Royal Holloway, University of London, Egham, TW20 0EX, United Kingdom
20Department of Physics and Astronomy,
Technion—Israel Institute of Technology, Haifa 32000, Israel
21Department of Physics, University of Washington,
PO Box 351560, Seattle, WA 98195-1460, USA
22Department of Particle Physics and Astrophysics,
Weizmann Institute of Science, Rehovot 76100, Israel
23Department of Physics & Astronomy, University of Sussex,
Sussex House, Falmer, Brighton, BN1 9RH, United Kingdom
24Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8602, Japan
25University of Manchester, School of Physics and Astronomy,
Schuster Building, Oxford Rd, Manchester M13 9PL, United Kingdom
26Dipartimento di Fisica “Ettore Pancini”, Universit`a di Napoli Federico II,
Complesso Universitario di Monte S. 2
10D´epartement de Physique Nucl´eaire et Corpusculaire,
University of Geneva, CH-1211 Geneva 4, Switzerland
11Nikhef National Institute for Subatomic Physics,
Science Park 105, 1098 XG Amsterdam, Netherlands
12L2IT, Universit´e de Toulouse, CNRS/IN2P3, UPS, Toulouse, France
13Department of Physics, Tsinghua University, Beijing, China
14INFN Sezione di Genova, Via Dodecaneso, 33–16146, Genova, Italy
15University of Oregon, Eugene, OR 97403, USA
16Affiliated with an international laboratory covered by a cooperation agreement with CERN. 17Institute of Space Science—INFLPR Subsidiary, Bucharest, Romania
18Theoretical Physics Division, Fermi National Accelerator Laboratory, Batavia, IL 60510, USA
19Royal Holloway, University of London, Egham, TW20 0EX, United Kingdom
20Department of Physics and Astronomy,
Technion—Israel Institute of Technology, Haifa 32000, Israel
21Department of Physics, University of Washington,
PO Box 351560, Seattle, WA 98195-1460, USA
22Department of Particle Physics and Astrophysics,
Weizmann Institute of Science, Rehovot 76100, Israel
23Department of Physics & Astronomy, University of Sussex,
Sussex House, Falmer, Brighton, BN1 9RH, United Kingdom
24Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8602, Japan
25University of Manchester, School of Physics and Astronomy,
Schuster Building, Oxford Rd, Manchester M13 9PL, United Kingdom
26Dipartimento di Fisica “Ettore Pancini”, Universit`a di Napoli Federico II,
Complesso Universitario di Monte S.Where the paper says it
Where the paper says it
Where the paper says it
Appendix A
The position resolution is evaluated with a track-extrapolation method for each film. Most plates exhibit resolutions of 0. p. 5 Overview of the EM shower reconstruction and identification pipeline, showing the three main
stages: pre-selection, reconstruction, and identification. Preliminary Selection on Tracks
Muon tracks traversing the full detector depth are characterized by large segment counts and
small scattering angles, whereas EM shower primary tracks are short (initiating cascades within
a few radiation lengths) and exhibit larger apparent scattering due to early pair production and
bremsstrahlung. Schematic view of the FASERν detector [4], consisting of tungsten plates interleaved with OPERAtype emulsion films. Each emulsion film comprises two 65 µm emulsion layers on each side of a 210 µm polystyrene
base [6]. A preliminary cylindrical search volume is then defined around the initial axis, with radius
100 µm and length 8 cm (approximately 18 radiation lengths, spanning 56 plates). Segments are
included in the preliminary shower candidate if they belong to a track with at least 3 segments
(Nseg ≥ 3), have a maximum perpendicular distance from the axis ≤ 100 µm, a maximum angular
deviation between the segment direction and the initial axis direction ≤ 10 mrad, and a minimum
distance of closest approach between the segment trajectory and the initial axis ≤ 50 µm. Measured data quality metrics for both test beam modules, evaluated using the methods described
in Ref. Parameter 100 GeV (T1202) 200 GeV (T1101)
Position resolution 0. 45 mrad
Angular resolution (σtan θy
) 1. 44 mrad
Single-film efficiency (peak) ∼85% ∼95%
2. A right-handed coordinate system is adopted throughout this paper: the Z-axis points along
the beam direction, X is horizontal transverse, and Y is vertical transverse. The achieved beam
conditions were:
• 100 GeV (module T1202): 40–50 particles per spill, electron purity >80%; 5
• 200 GeV (module T1101): 40–60 particles per spill, electron purity >90%. The target exposure density was approximately 8 electrons/cm2
.Where the paper says it
Where the paper says it
Where the paper says it
Where the paper says it
Where the paper says it
Where the paper says it
Where the paper says it
Green — the paper says it, and the page is printed. Red — no passage carries it, so treat that sentence as unverified. The same check runs on your own text: check a summary against its source, $5.
Improvements for AI systems
-
Adaptive clustering for shower reconstruction allows systems to determine
shower axes without energy-dependent parameter tuning,
enabling reliable identification across a broad energy range from 50 GeV to multi-TeV without requiring separate models for different energies. -
A multi-level identification chain, comprising
track pre-selection, a cut-based selection, and a BDT classifier,
achieves extremely high background rejection rates of 99.99% at 100 GeV and 99.94% at 200 GeV while maintaining high signal efficiency. -
The BDT classifier uses
ten shower shape variables: six longitudinal, three transverse and clustering, and one angular,
which are specifically designed toremain stable across the broad FASERν energy range, enabling a single trained classifier to be applied at 50 GeV and above without retuning.
-
Energy reconstruction using the total number of segments yields relative biases of
+0.6% at 100 GeV and -0.8% at 200 GeV,
providing calibrated energy estimates with resolutions of25.4 +/- 2.1% at 100 GeV and 22.6 +/- 1.5% at 200 GeV.
-
The system can quantify the impact of detector imperfections by measuring how
single-film efficiency variations systematically shift the observed shower multiplicity and consequently the reconstructed energy,
allowing for precise systematic uncertainty modeling.
Abstract
We present methods for electromagnetic shower reconstruction and identification in the FASERnu emulsion detector using 100 GeV and 200 GeV electron test-beam data from the CERN SPS H4 beamline. The reconstruction employs a clustering-based algorithm without energy-dependent tuning to determine shower axes. A multi-level identification chain comprising track pre-selection, a cut-based selection, and a BDT classifier achieves combined background rejection rates of 99.99% (100 GeV) and 99.94% (200 GeV). The method reaches total reconstruction and identification efficiencies of 58.9% (100 GeV) and 70.8% (200 GeV) evaluated from simulated samples. Energy reconstruction using the total number of reconstructed segments as the calorimetric estimator yields relative biases of +0.6% (100 GeV) and-0.8% (200 GeV), with resolutions of 25.4% and 22.6%, respectively. Systematic uncertainties on the energy reconstruction are dominated by variations in emulsion film detection efficiency, with totals of (+10.9%/-8.2%) at 100 GeV and (+10.3%/-6.9%) at 200 GeV. The methodology provides a validated framework for electron neutrino identification with the FASERnu detector at the LHC.
Sources
- Detecting and Studying High-Energy Collider Neutrinos with FASER at the LHC
- Technical Proposal for FASER: ForwArd Search ExpeRiment at the LHC
- The FASER Detector
- Technical Proposal: FASERnu
- Neutrino Rate Predictions for FASER
- First neutrino interaction candidates at the LHC
- First Direct Observation of Collider Neutrinos with FASER at the LHC
- First Measurement of the $\nu_e$ and $\nu_\mu$ Interaction Cross Sections at the LHC with FASER's Emulsion Detector
- Momentum Measurement of Charged Particles in FASER's Emulsion Detector at the LHC
- Observation of collider muon neutrinos with the SND@LHC experiment
- Observation of collider neutrinos without final state muons with the SND@LHC experiment
- A Low Energy Rare Event Search with the Majorana Demonstrator
- Reconstruction and Performance Evaluation of FASER's Emulsion Detector at the LHC
- XGBoost: A Scalable Tree Boosting System
Related papers
- DrSai: an agentic AI system toward autonomous physics analysis workflows at BESIII
- CANTON- mu Proposal: A Next-Generation Muon g-2 Measurement at Sub-0.1 ppm Precision
- Search for dark photon dark matter near 1,meV using a superconducting mixer
- ANUBIS detector and its sensitivity to neutral long-lived particles
- How to scale your HEP ML models: A recipe for robust architecture comparisons at scale
- Search for the 16 O(ppp) to 13 C pi+ pi+ e+ Decay Mode in Super-Kamiokande Using Machine Learning Techniques