CANTON- mu Proposal: A Next-Generation Muon g-2 Measurement at Sub-0.1 ppm Precision

arXiv:2512.11486 · hep-ex, hep-ph · Submitted 2025-12-12 · Read on arXiv

Listen

Radio episode about this paper

Transcript

Introduction to the show: ident: High Energy Physics: Experiment. The day in high-energy experiment: detectors, searches and limits.

Kai: We're looking at the paper: "CANTON- mu Proposal".

Mira: Here's the gist of the paper. We propose CANTON- mu (Coherent Anomalous magnetic moment Observation with muon), a next-generation precision measurement of the muon anomalous magnetic moment (g-2) planned at the High Intensity Heavy-Ion Accelerator Facility (HIAF) in Huizhou, China.

Kai: This work develops HIAF-specific experimental schemes designed to relax the conventional magic-momentum constraint, thereby allowing greater flexibility in beam momentum choice.

Mira: The study assesses expected muon intensity at HIAF and corresponding statistical sensitivity for various experimental concepts, identifying distinctive systematic effects for each scheme and proposing quantitative systematic-uncertainty targets.

Kai: Statistical projections indicate prospective total precisions of 0.1 ppm in Phase-I, comparable to the current Fermilab precision, with the potential to reach the 0.05 ppm level in Phase-II following planned HIAF upgrades.

Title and authors: Kai: So, we're looking at this paper titled "CANTON- mu Proposal: A Next-Generation Muon g-two Measurement at Sub-zero point one ppm Precision" <ref:2512.11486#pg1,2 Measurement at Sub-0.1 ppm Precision>. It sounds like they're proposing a really advanced way to measure the muon anomalous magnetic moment, g minus two <ref:2512.11486#pg1,the muon anomalous magnetic moment>.

Mira: Yeah, it’s aiming for a precision level below one part per thousand in the measurement of this value. That’s seriously pushing the limits of what we can achieve right now with these kinds of experiments.

Lev: What I'm hearing is they are tackling that pesky magic momentum issue, which is usually a big hurdle for these types of measurements.

Kai: Exactly. They’re proposing two different experimental concepts to get around that constraint, trying to allow for more flexible beam momentum choices instead of being stuck at one specific energy level.

Mira: It’s about designing the experiment so you aren't totally locked into that magic momentum condition anymore, which opens up a lot more room for testing.

Lev: And they spend a lot of time looking at how this translates to actual hardware, considering the required precision and what that means for error correction overhead.

The paper's summary: Kai: So, the core idea here is about using a High Intensity Heavy-Ion Accelerator Facility, HIAF in China. They’re planning this next-generation measurement there to get that precision.

Mira: They are focusing on how the statistical sensitivity scales with beam energy and magnetic field, showing that raising the muon energy helps improve precision by scaling linearly with the magnetic field and muon lifetime.

Lev: That scaling is important because it shows a clear path to better statistics by just pushing up the energy of what you're measuring without needing an impossibly huge number of muons.

Kai: And they are also looking at how much data they can actually get, projecting expected muon flux intensities, like three point eight times ten to the six muons per second at three point five gigaelectron volts per c.

Mira: The paper also dives into the systematic uncertainty targets, setting specific goals for what those uncertainties should be for both their proposed concepts.

Lev: For instance, they target a total systematic uncertainty of about forty-nine parts per billion for Concept A, and around twenty-seven parts per billion for Phase I and Phase II of Concept B.

The paper's improvements: Kai: The authors propose two distinct storage ring concepts to overcome the magic momentum limitation they talked about earlier. Concept A uses a Sector Magnet with a Polarized Proton Co Magnetometer instead of relying on that fixed energy point.

Mira: Concept B is different; it uses Hybrid Weak Focusing Upgrades to the Fermilab Scheme, using both electric and magnetic quadrupoles to tune them so they achieve an effective magic condition for higher momentum operation.

Lev: From an engineering standpoint, Concept A seems more complex because it involves that co-magnetometer setup and determining the magnetic field in that way.

Kai: Concept B, though, seems more familiar because it’s based on upgrades to the existing Fermilab scheme, just tweaked to allow for higher energy operation.

Mira: What I find interesting is how they are analyzing the residual electric field correction in Concept B. They suggest that this leading residual correction near the cancellation point is second order in the momentum deviation.

Lev: If that’s true, it means we can be pretty confident if we keep our momentum control tight, because a small change in momentum won't blow up the error term too much.

Conclusion: Kai: So, to wrap up on this "CANTON- mu Proposal: A Next-Generation Muon g-two Measurement at Sub-zero point one ppm Precision", they are looking at achieving a total precision of about zero point one ppm in Phase I and aiming for zero point zero five ppm in Phase II with HIAF upgrades <ref:2512.11486#pg1,2 Measurement at Sub-0.1 ppm Precision>.

Mira: This level of precision is what makes it significant, because it’s comparable to the current Fermilab results, but with the potential to get better later.

Lev: And for those of us building hardware, seeing a systematic uncertainty target around twenty-seven parts per billion for Concept B in Phase I gives us a concrete number to worry about when designing the magnets and focusing optics.

Kai: It’s also important that they mentioned the ultimate goal is testing the Standard Model and probing new physics at multi-TeV scales if we can get there.

Mira: And they even point out that focusing on negative muon measurements lets us compare directly with positive muon results, which really strengthens tests of CPT symmetry within the Standard Model Extension.

Lev: That ten to the minus twenty four gigaelectron volt level sensitivity for CPT violation is a huge potential window, an order of magnitude beyond what we currently have <ref:2512.11486#pg1>.

Kai: So they are proposing these two paths to push precision, and it's a test of how well we can control these complex experimental systems at this scale.

University of Liverpool University Advanced Energy Science and Technology Guangdong Laboratory Institute of Modern Physics Institute of Advanced Energy Science and Technology Guangdong Laboratory School of Nuclear Science and Technology University of Chinese Academy of Sciences School of Physics and Astronomy Shanghai Jiao Tong University State Key Laboratory of Nuclear Physics and Technology School of Physics Peking University

hep-ex, hep-ph

Submitted: 2025-12-12

Updated: 2026-11-09

Comments: Published in Eur. Phys. J. C. DOI: 10.1140/epjc/s10052-026-16588-x

Journal ref: Eur. Phys. J. C 86, 1292 (2026)

DOI: 10.1140/epjc/s10052-026-16588-x

License: http://creativecommons.org/licenses/by/4.0/

Importance score: 100/100

The gist: We propose CANTON- mu (Coherent Anomalous magnetic moment Observation with muon), a next-generation precision measurement of the muon anomalous magnetic moment (g-2) planned at the High Intensity…

Key concepts

Magic Momentum Constraint
Conventional muon g-2 experiments are limited by a 'magic momentum' around 3.1 GeV/c. This constraint fixes the muon's momentum, restricting experimental flexibility. CANTON-$μ aims to develop new schemes that eliminate this fix, allowing for higher energy operation.
Concept A: Sector Magnet
This concept uses a Sector Magnet with a Polarized Proton Co-Magnetometer. It removes the magic momentum constraint by using natural edge fields for vertical focusing and employs a polarized proton beam to determine the magnetic field within the ring.
Concept B: Hybrid Weak Focusing Upgrades
This concept involves hybrid electric and magnetic quadrupoles. By tuning their relative focusing indices, it creates an 'effective-magic' condition, enabling operation at higher muon momenta than conventional methods allow.

Terminology

Summary

We propose CANTON- mu (Coherent Anomalous magnetic moment Observation with muon), a next-generation precision measurement of the muon anomalous magnetic moment (g-2) planned at the High Intensity Heavy-Ion Accelerator Facility (HIAF) in Huizhou, China. p. 0

Where the paper says it

We propose a next-generation precision measurement of the muon anomalous magnetic moment (muon 𝑔−2) at the High Intensity Heavy-Ion Accelerator Facility (HIAF) in Huizhou, China. We refer to this proposed experimental programme as CANTON-𝜇 (Coherent Anomalous magNetic momenT ObservatioN with muon).

This work develops HIAF-specific experimental schemes designed to relax the conventional magic-momentum constraint, thereby allowing greater flexibility in beam momentum choice. p. 0
Where the paper says it

HIAF’s intense, pulsed GeV-scale muon beams, particularly for negative muons, provide a promising basis for this programme. Building on two previously proposed storage-ring concepts, this work develops HIAF-specific experimental schemes that relax the conventional magic-momentum constraint and allow greater flexibility in the choice of beam momentum.

The study assesses expected muon intensity at HIAF and corresponding statistical sensitivity for various experimental concepts, identifying distinctive systematic effects for each scheme and proposing quantitative systematic-uncertainty targets. p. 0
Where the paper says it

We assess the expected muon intensity at HIAF and the corresponding statistical sensitivity. For each scheme, we identify its distinctive systematic effects, examine feasible control strategies, and propose quantitative systematic-uncertainty targets.

Statistical projections indicate prospective total precisions of 0. p. 0
Where the paper says it

For each scheme, we identify its distinctive systematic effects, examine feasible control strategies, and propose quantitative systematic-uncertainty targets. Together, the statistical projections and systematic-uncertainty targets indicate prospective total precisions of 0.

1 ppm in Phase-I, comparable to the current Fermilab precision, with the potential to reach the 0. p. 0
Where the paper says it

Together, the statistical projections and systematic-uncertainty targets indicate prospective total precisions of 0. 1 ppm in Phase-I, comparable to the current Fermilab precision, with the potential to reach the 0.

05 ppm level in Phase-II following planned HIAF upgrades. p. 0
Where the paper says it

1 ppm in Phase-I, comparable to the current Fermilab precision, with the potential to reach the 0. 05 ppm level in in Phase-II following the planned HIAF upgrade.

At ultimate projected precision, this measurement is intended to provide a stringent test of the Standard Model and probe new physics at multi-TeV scales. p. 0
Where the paper says it

05 ppm level in in Phase-II following the planned HIAF upgrade. At the ultimate projected precision, the measurement would provide a stringent test of the Standard Model and probe new physics at multi-TeV scales.

Furthermore, focusing on negative-muon measurements will enable a direct comparison with existing high-precision positive-muon results and strengthen tests of CPT symmetry within the Standard-Model Extension, achieving projected sensitivity at the 10-24 GeV level. p. 0
Where the paper says it

At the ultimate projected precision, the measurement would provide a stringent test of the Standard Model and probe new physics at multi-TeV scales. A focus on negative-muon measurements would enable direct comparison with existing high-precision positive-muon results and strengthen tests of CPT symmetry in the muon sector within the Standard-Model Extension, with a projected sensitivity at the 10−24 GeV level, an order of magnitude beyond current limits.

The Standard Model prediction for muon g-2 is currently dominated by hadronic vacuum polarization (HVP) and hadronic light-by-light (HLbL) contributions, which are governed by strong interaction dynamics. p. 0

Where the paper says it

In general, the SM prediction consists of QED, electroweak, and hadronic contributions. The QED [14–20] and electroweak [21– 24] terms are known with sub-5 ppb precision, while the overall theoretical uncertainty is dominated entirely by the hadronic corrections, namely the hadronic vacuum polarization (HVP) [25– 44] and hadronic light-by-light (HLbL) [23, 45–73] contributions governed by the strong interaction.

Theoretical uncertainties in this area are currently dominated by these hadronic corrections, with data-driven methods and lattice QCD approaches being pursued to calculate them. p. 0
Where the paper says it

These quantities involve low-energy, multi-scale QCD dynamics that cannot be treated perturbatively. Two complementary approaches are being pursued to calculate the HVP and HLbL contributions: data-driven (dispersive) methods [45, 74, 75] and lattice QCD [76–78].

The latest recommendation adopts the lattice-QCD average for the leading-order HVP as the basis of the Standard Model prediction. p. 1
Where the paper says it

Status of muon 𝑔 −2 experimental measurements and SM predictions, with the latter showing results from both data-driven (green) and lattice QCD (orange) calculations of the LO-HVP. In light of the tensions affecting the dispersive method, the latest recommendation in 2025 adopts the lattice-QCD average for the leading-order HVP as the basis of the SM prediction.

Experimentally, conventional muon g-2 experiments typically rely on injecting muons at a magic momentum of about 3.1 GeV/c into a continuous magnetic storage region, utilizing electric quadrupoles for vertical focusing. p. 1

Where the paper says it

Experimentally, all muon 𝑔−2 experiments since CERNIII [2, 83] have relied on essentially the same methodology: injecting muons at the so-called “magic momentum” of about 3. 1 GeV/𝑐 into a continuous magnetic storage region, using electric quadrupoles (EQs) for vertical focusing, and calibrating the magnetic field with fixed and movable nuclear magnetic resonance (NMR) probes.

This approach is inherently limited by the magic- j condition, which fixes the muon momentum. p. 1
Where the paper says it

Combining the experimentally determined frequency ratio with the definition of the Bohr magneton, 𝜇B = 𝑒ℏ/2𝑚𝑒, the muon anomalous magnetic moment can be expressed as 𝑎𝜇 = 𝜔𝑎 𝜔e ′ 𝑝 (𝑇𝑟 ) 𝜇 ′ p (𝑇𝑟 ) 𝜇B 𝑚𝜇 𝑚e , (4) where the ratios 𝜇 ′ p (𝑇𝑟 )/𝜇B and 𝑚𝜇/𝑚𝑒 are precisely known to 22 ppb from other experiments [84]. While this conventional approach has been extraordinarily successful, its reliance on the magic-𝛾 condition fixes the muon momentum, limiting the flexibility to operate at higher muon

To operate at higher energies, new experiments must devise strategies to suppress the electric-field correction arising from the electric-field term in Equation (1). p. 2
Where the paper says it

Operation at higher muon energies requires abandoning the conventional magic-𝛾 condition. A new experiment must therefore suppress the electric-field correction arising from the 𝛽® × 𝐸® term in Eq.

CANTON- mu proposes two distinct storage-ring concepts: Concept A utilizes a Sector Magnet with a Polarized Proton Co-Magnetometer, which eliminates the need for magic momentum by employing natural edge fields for vertical focusing and utilizing a polarized proton beam as an in-ring co-magnetometer to determine the magnetic field. p. 5

Where the paper says it

The natural edge fields of each sector provide vertical focusing (edge focusing), eliminating the need for electrostatic quadrupoles. μ⁻ beam HFRS (HIRIBL) Magnet Kicker Polarized proton Polarimeter e⁻ detector Edge focusing Fig.

Concept B involves Hybrid Weak Focusing Upgrades to the Fermilab Scheme, which employs both electric and magnetic quadrupoles to tune the relative electric and magnetic focusing indices to achieve an effective-magic condition, thereby permitting higher-momentum operation.

The feasibility study evaluates HIAF's beam properties, including projected muon flux intensities (e.g., 3.8 times 10 6 mu+/s at 3. p. 4

Where the paper says it

Adopting a Fermilab-like momentum acceptance and injection efficiency therefore provides a conservative baseline for HIAF, corresponding to an expected stored population of approximately 104–105 muons per fill. Therefore, the lower HIAF repetition rate of 3 Hz concentrates the events into fewer fills and increases the per-fill occupancy up to approximately three times that at Fermilab.

5 GeV/c), and assesses achievable sensitivities based on these parameters for Phase-I (0. p. 2
Where the paper says it

We then adapt and assess two previously proposed muon storage ring (SR) concepts for the HIAF beam conditions (Sec. 3) and evaluate their achievable sensitivities (Sec.

10–0.14 ppm) and Phase-II (up to 0. p. 0
Where the paper says it

Together, the statistical projections and systematic-uncertainty targets indicate prospective total precisions of 0. 1 ppm in Phase-I, comparable to the current Fermilab precision, with the potential to reach the 0.

05 ppm). Systematic uncertainty targets are established for both concepts: Concept A targets a total systematic uncertainty of approximately 49 ppb, while Concept B targets a similar level of 27 ppb for Phase I and 27 ppb for Phase II. p. 9
Where the paper says it

The projected systematic uncertainty targets for each category are discussed in the following subsections. 1 Muon precession frequency 𝜔 𝑚 𝑎,𝜇 The systematic uncertainty associated with 𝜔 𝑚 𝑎,𝜇 reached 30 ppb in the final Fermilab analysis and was dominated by: (i) the modelling of coherent betatron oscillation (CBO), (ii) the various gain responses of the calorimeters and (iii) the pileup.

These projections suggest CANTON- mu could achieve an overall precision of approximately 0. p. 2
Where the paper says it

Although innovative, this approach currently has a relatively low overall muon efficiency. Its Phase-I design precision of approximately 0.

10 ppm in Phase I, comparable to Fermilab E989, and potentially reach 0. p. 0
Where the paper says it

Together, the statistical projections and systematic-uncertainty targets indicate prospective total precisions of 0. 1 ppm in Phase-I, comparable to the current Fermilab precision, with the potential to reach the 0.

05 ppm in Phase II with the planned HIAF-U upgrade, improving upon the current Fermilab benchmark by a factor of approximately 3. p. 0
Where the paper says it

1 ppm in Phase-I, comparable to the current Fermilab precision, with the potential to reach the 0. 05 ppm level in in Phase-II following the planned HIAF upgrade.

Such precision offers significant physics opportunities, extending indirect sensitivity to new physics in chirally enhanced scenarios and providing a unique test of CPT symmetry at the O(10-24 GeV) level through measurements involving both mu+ and mu-. p. 0
Where the paper says it

At the ultimate projected precision, the measurement would provide a stringent test of the Standard Model and probe new physics at multi-TeV scales. A focus on negative-muon measurements would enable direct comparison with existing high-precision positive-muon results and strengthen tests of CPT symmetry in the muon sector within the Standard-Model Extension, with a projected sensitivity at the 10−24 GeV level, an order of magnitude beyond current limits.

The next steps involve end-to-end beam and spin tracking, realistic field and lattice modeling, prototype development of principal instrumentation, and experimental validation of proposed systematic control strategies.

Green — the paper says it, and the page is printed. Red — no passage carries it, so treat that sentence as unverified. The same check runs on your own text: check a summary against its source, $5.

Improvements for AI systems

  1. Enhanced systematic uncertainty budgeting: The AI can perform detailed sensitivity studies by combining statistical projections (Table 2) with systematic targets (Table 3) for both Concept A and Concept B to provide a comprehensive, conservative total experimental systematic uncertainty target of approximately 49 ppb for Phase I and up to 53 ppb for Phase II.

  2. Novel physics constraint mapping: The system can use the projected sensitivity reaches in muon anomalous magnetic moment measurements (Phase I at 0.1 ppm and Phase II at 0.05 ppm) to translate the uncertainty budget into lower limits on new physics mass scales, such as probing mass scales up to 1 TeV for tree-level interactions under SM2020 predictions.

  3. CPT symmetry testing: The AI can utilize the projected sensitivity in comparing positive and negative muon measurements at HIAF to constrain CPT violation coefficients, specifically projecting a sensitivity at the 10-24 GeV level for this test, an order of magnitude beyond current limits.

  4. Concept-specific systematic mitigation: For Concept A, the AI can identify that the time-independent magnetic focusing eliminates the tune evolution associated with the settling of the electrostatic quadrupoles, suggesting a design target allocation of 14 ppb for CBO modeling to achieve a total uncertainty budget for muon precession frequency of approximately 24 ppb.

  5. Hybrid focusing optimization: For Concept B, the AI can analyze Eq. (23) to determine that the leading residual electric-field correction near the cancellation point is therefore second order in the momentum deviation, suggesting a design target of sigma Ce less than 20 ppb for this correction term.

Abstract

We propose a next-generation precision measurement of the muon anomalous magnetic moment (muon g-2) at the High Intensity Heavy-Ion Accelerator Facility (HIAF) in Huizhou, China. We refer to this proposed experimental programme as CANTON- μ (Coherent Anomalous magNetic momenT ObservatioN with muon). HIAF's intense, pulsed GeV-scale muon beams, particularly for negative muons, provide a promising basis for this programme. Building on two previously proposed storage-ring concepts, this work develops HIAF-specific experimental schemes that relax the conventional magic-momentum constraint and allow greater flexibility in the choice of beam momentum. We assess the expected muon intensity at HIAF and the corresponding statistical sensitivity. For each scheme, we identify its distinctive systematic effects, examine feasible control strategies, and propose quantitative systematic-uncertainty targets. Together, the statistical projections and systematic-uncertainty targets indicate prospective total precisions of 0.1 ppm in Phase-I, comparable to the current Fermilab precision, with the potential to reach the 0.05 ppm level in Phase-II following the planned HIAF upgrade. At the ultimate projected precision, the measurement would provide a stringent test of the Standard Model and probe new physics at multi-TeV scales. A focus on negative-muon measurements would enable direct comparison with existing high-precision positive-muon results and strengthen tests of CPT symmetry in the muon sector within the Standard-Model Extension, with a projected sensitivity at the 10-24 GeV level, an order of magnitude beyond current limits.

Sources

Related papers