CANTON- mu Proposal: A Next-Generation Muon g-2 Measurement at Sub-0.1 ppm Precision
summary
The gist
We propose CANTON- mu (Coherent Anomalous magnetic moment Observation with muon), a next-generation precision measurement of the muon anomalous magnetic moment (g-2) planned at the High Intensity…
In short
CANTON-$μ proposes CANTON-$μ∟, a next-generation muon g-2 experiment at HIAF to achieve sub-0.1 ppm precision. It explores two storage ring concepts (A and B) to overcome momentum constraints, projecting 0.1 ppm in Phase I and 0.05 ppm in Phase II. This measurement will test the Standard Model and probe new physics at multi-TeV scales, with potential for CPT symmetry tests.
Key concepts
- Magic Momentum Constraint
- Conventional muon g-2 experiments are limited by a 'magic momentum' around 3.1 GeV/c. This constraint fixes the muon's momentum, restricting experimental flexibility. CANTON-$μ aims to develop new schemes that eliminate this fix, allowing for higher energy operation.
- Concept A: Sector Magnet
- This concept uses a Sector Magnet with a Polarized Proton Co-Magnetometer. It removes the magic momentum constraint by using natural edge fields for vertical focusing and employs a polarized proton beam to determine the magnetic field within the ring.
- Concept B: Hybrid Weak Focusing Upgrades
- This concept involves hybrid electric and magnetic quadrupoles. By tuning their relative focusing indices, it creates an 'effective-magic' condition, enabling operation at higher muon momenta than conventional methods allow.
Terminology used across episodes
This episode discusses
- CANTON- mu Proposal: A Next-Generation Muon g-2 Measurement at Sub-0.1 ppm Precision · Paper Radio
- Final Report on the Measurement of the Positive Muon Anomalous Magnetic Moment at Fermilab to 127 ppb
- A further study on the high-precision optics for HIAF-BRing
- Continuous coherent spin-frequency metrology in storage rings via resonant beam-driven detection
- Search for a muon EDM using the frozen-spin technique
The paper
CANTON- mu Proposal: A Next-Generation Muon g-2 Measurement at Sub-0.1 ppm Precision · Read on arXiv
University of Liverpool University Advanced Energy Science and Technology Guangdong Laboratory Institute of Modern Physics Institute of Advanced Energy Science and Technology Guangdong Laboratory School of Nuclear Science and Technology University of Chinese Academy of Sciences School of Physics and Astronomy Shanghai Jiao Tong University State Key Laboratory of Nuclear Physics and Technology School of Physics Peking University
We propose a next-generation precision measurement of the muon anomalous magnetic moment (muon g-2) at the High Intensity Heavy-Ion Accelerator Facility (HIAF) in Huizhou, China. We refer to this proposed experimental programme as CANTON- μ (Coherent Anomalous magNetic momenT ObservatioN with muon). HIAF's intense, pulsed GeV-scale muon beams, particularly for negative muons, provide a promising basis for this programme. Building on two previously proposed storage-ring concepts, this work develops HIAF-specific experimental schemes that relax the conventional magic-momentum constraint and allow greater flexibility in the choice of beam momentum. We assess the expected muon intensity at HIAF and the corresponding statistical sensitivity. For each scheme, we identify its distinctive systematic effects, examine feasible control strategies, and propose quantitative systematic-uncertainty targets. Together, the statistical projections and systematic-uncertainty targets indicate prospective total precisions of 0.1 ppm in Phase-I, comparable to the current Fermilab precision, with the potential to reach the 0.05 ppm level in Phase-II following the planned HIAF upgrade. At the ultimate projected precision, the measurement would provide a stringent test of the Standard Model and probe new physics at multi-TeV scales. A focus on negative-muon measurements would enable direct comparison with existing high-precision positive-muon results and strengthen tests of CPT symmetry in the muon sector within the Standard-Model Extension, with a projected sensitivity at the 10-24 GeV level, an order of magnitude beyond current limits.
DOI: 10.1140/epjc/s10052-026-16588-x
Transcript
Introduction to the show: ident: High Energy Physics: Experiment. The day in high-energy experiment: detectors, searches and limits.
Kai: We're looking at the paper: "CANTON- mu Proposal".
Mira: Here's the gist of the paper. We propose CANTON- mu (Coherent Anomalous magnetic moment Observation with muon), a next-generation precision measurement of the muon anomalous magnetic moment (g-2) planned at the High Intensity Heavy-Ion Accelerator Facility (HIAF) in Huizhou, China.
Kai: This work develops HIAF-specific experimental schemes designed to relax the conventional magic-momentum constraint, thereby allowing greater flexibility in beam momentum choice.
Mira: The study assesses expected muon intensity at HIAF and corresponding statistical sensitivity for various experimental concepts, identifying distinctive systematic effects for each scheme and proposing quantitative systematic-uncertainty targets.
Kai: Statistical projections indicate prospective total precisions of 0.1 ppm in Phase-I, comparable to the current Fermilab precision, with the potential to reach the 0.05 ppm level in Phase-II following planned HIAF upgrades.
Title and authors: Kai: So, we're looking at this paper titled "CANTON- mu Proposal: A Next-Generation Muon g-two Measurement at Sub-zero point one ppm Precision" <ref:2512.11486#pg1,2 Measurement at Sub-0.1 ppm Precision>. It sounds like they're proposing a really advanced way to measure the muon anomalous magnetic moment, g minus two <ref:2512.11486#pg1,the muon anomalous magnetic moment>.
Mira: Yeah, it’s aiming for a precision level below one part per thousand in the measurement of this value. That’s seriously pushing the limits of what we can achieve right now with these kinds of experiments.
Lev: What I'm hearing is they are tackling that pesky magic momentum issue, which is usually a big hurdle for these types of measurements.
Kai: Exactly. They’re proposing two different experimental concepts to get around that constraint, trying to allow for more flexible beam momentum choices instead of being stuck at one specific energy level.
Mira: It’s about designing the experiment so you aren't totally locked into that magic momentum condition anymore, which opens up a lot more room for testing.
Lev: And they spend a lot of time looking at how this translates to actual hardware, considering the required precision and what that means for error correction overhead.
The paper's summary: Kai: So, the core idea here is about using a High Intensity Heavy-Ion Accelerator Facility, HIAF in China. They’re planning this next-generation measurement there to get that precision.
Mira: They are focusing on how the statistical sensitivity scales with beam energy and magnetic field, showing that raising the muon energy helps improve precision by scaling linearly with the magnetic field and muon lifetime.
Lev: That scaling is important because it shows a clear path to better statistics by just pushing up the energy of what you're measuring without needing an impossibly huge number of muons.
Kai: And they are also looking at how much data they can actually get, projecting expected muon flux intensities, like three point eight times ten to the six muons per second at three point five gigaelectron volts per c.
Mira: The paper also dives into the systematic uncertainty targets, setting specific goals for what those uncertainties should be for both their proposed concepts.
Lev: For instance, they target a total systematic uncertainty of about forty-nine parts per billion for Concept A, and around twenty-seven parts per billion for Phase I and Phase II of Concept B.
The paper's improvements: Kai: The authors propose two distinct storage ring concepts to overcome the magic momentum limitation they talked about earlier. Concept A uses a Sector Magnet with a Polarized Proton Co Magnetometer instead of relying on that fixed energy point.
Mira: Concept B is different; it uses Hybrid Weak Focusing Upgrades to the Fermilab Scheme, using both electric and magnetic quadrupoles to tune them so they achieve an effective magic condition for higher momentum operation.
Lev: From an engineering standpoint, Concept A seems more complex because it involves that co-magnetometer setup and determining the magnetic field in that way.
Kai: Concept B, though, seems more familiar because it’s based on upgrades to the existing Fermilab scheme, just tweaked to allow for higher energy operation.
Mira: What I find interesting is how they are analyzing the residual electric field correction in Concept B. They suggest that this leading residual correction near the cancellation point is second order in the momentum deviation.
Lev: If that’s true, it means we can be pretty confident if we keep our momentum control tight, because a small change in momentum won't blow up the error term too much.
Conclusion: Kai: So, to wrap up on this "CANTON- mu Proposal: A Next-Generation Muon g-two Measurement at Sub-zero point one ppm Precision", they are looking at achieving a total precision of about zero point one ppm in Phase I and aiming for zero point zero five ppm in Phase II with HIAF upgrades <ref:2512.11486#pg1,2 Measurement at Sub-0.1 ppm Precision>.
Mira: This level of precision is what makes it significant, because it’s comparable to the current Fermilab results, but with the potential to get better later.
Lev: And for those of us building hardware, seeing a systematic uncertainty target around twenty-seven parts per billion for Concept B in Phase I gives us a concrete number to worry about when designing the magnets and focusing optics.
Kai: It’s also important that they mentioned the ultimate goal is testing the Standard Model and probing new physics at multi-TeV scales if we can get there.
Mira: And they even point out that focusing on negative muon measurements lets us compare directly with positive muon results, which really strengthens tests of CPT symmetry within the Standard Model Extension.
Lev: That ten to the minus twenty four gigaelectron volt level sensitivity for CPT violation is a huge potential window, an order of magnitude beyond what we currently have <ref:2512.11486#pg1>.
Kai: So they are proposing these two paths to push precision, and it's a test of how well we can control these complex experimental systems at this scale.
More episodes
- Daily Summary for 2026-11-19
- 2512.21290-Model-independent ZH production cross section at FCC-ee
- 2610.21982-First Observation of the Radiative Decay D 0 to gamma omega
- The day in conversation for 2026-11-19
- Daily Summary for 2026-11-19
- Daily Summary for 2026-11-18
- 2512.08065-Searches for Light Dark Matter and Evidence of Coherent Elastic Neutrino-Nucleus Scattering of Solar Neutrinos with the LUX-ZEPLIN (LZ) Experiment
- Daily Summary for 2026-11-18
- 2508.18022-Precision Measurements of the Electroweak Mixing Angle in the Region of the Z pole at the Large Hadron Collider
- 2512.23992-Prospect for measurement of CP-violating parameters of B s 0 to phi gamma at the Tera Z factory