Neutral kaon mass measurement with the CMD-3 detector at VEPP-2000

arXiv:2606.16779 · hep-ex · Submitted 2026-06-15 · Read on arXiv

Listen

Radio episode about this paper

Transcript

Introduction to the show: ident: High Energy Physics: Experiment. The day in high-energy experiment: detectors, searches and limits.

Kai: We're looking at the paper: "Neutral kaon mass measurement with the CMD-3 detector at VEPP-2000".

Mira: Here's the gist of the paper. Using more than 600 thousand K0 S → π+π− decays from the e+e− → ϕ(1020) → K0SKO L reaction, the neutral kaon mass has been measured with the CMD-3 detector at the VEPP-2000 collider m(K O S) = 497.587 ± 0.012 MeV/c squared, where the first uncertainty is statistical, the second is systematic, and the third is the uncertainty from the energy calibration.

Kai: Measurement Methodology The neutral kaon mass was determined using a method based on measuring an opening angle between pions from the K0 S → π+π− decay, which is called the "edge angle", ψc m(K0 S) = r E squared K0 S sin squared ψc squared + 4m squared π cos squared ψc squared.

Mira: This method utilizes the beam energies controlled by the back-scattering laser light photons and a calibration to the world average ϕ-meson mass.

Kai: The detector's tracking system provides momentum, angles, and dE/dX for charged tracks 4.

Paper summary: Kai: So wrapping up this discussion on "Neutral kaon mass measurement with the CMD-three detector at VEPP-two thousand" <ref:2606.16779#pg1,Neutral kaon mass measurement with the CMD-3 detector at VEPP-2000>. The neutral kaon mass is determined to be four hundred ninety-seven point five eight seven MeV per c squared, with an overall uncertainty estimated as zero point zero one two four MeV per c squared.

Mira: That result is in good agreement with all high statistical experiments and has better accuracy than some of them. It shows that their method works well for getting a precise number in this context.

Lev: The precision of the measurement is really dominated by the uncertainties in the energy measurements, which we talked about earlier, specifically the beam energy calibration using the world average phi meson mass.

Kai: So when you look at what this paper implies for the future, it's that achieving even better precision will require focusing on controlling those beam energies and nailing those systematic error budgets down. It’s a practical engineering challenge as much as a theoretical one.

Mira: I think the main implication is demonstrating that this specific edge angle approach can yield results with high accuracy when you properly handle the various corrections like radiative effects and angle corrections.

Lev: And for future work, we need to look at how to build on this by developing error correction techniques that account for those energy shifts at phi resonance and maybe explore ways to reduce the impact of those radiative effects further.

Kai: So yeah, that's the essence of it—it’s a very detailed measurement where the final result is really as much about controlling how you measure things than just collecting enough data.

Conclusion: Kai: So, we've looked at how they measured that neutral kaon mass using those pion decays from the K zero S to pi plus pi minus decay, and now we're getting to the wrap-up of this paper.

Mira: They’re calling it "Neutral kaon mass measurement with the CMD-three detector at VEPP-two thousand." It sounds very specific, doesn't it?

Lev: Yeah, it is specific because they are talking about a particular detector setup and a particular measurement technique. I mean, for real hardware like what we build for error correction research, those details matter a ton for the overhead.

Kai: Exactly. The authors are essentially presenting how to get that neutral kaon mass number with this method, and it gives us a very precise value of four hundred ninety-seven point five eight seven MeV per c squared.

Mira: It's good that they managed to get a result that agrees well with all the other high statistical experiments we have done on this. It shows the consistency across different measurements.

Lev: But we gotta remember, the uncertainty budget is what really tells us how much real hardware noise or calibration error is messing with that number. The second largest source of error comes from how they calibrate their beam energy using the phi meson mass data.

Kai: Right, so even if the statistical counting of those decay events was perfect, you still have to deal with that systematic uncertainty from calibrating your energy scale against something else.

Mira: That calibration constant they mentioned, delta E send, is a key piece of information because it points to where the biggest systematic uncertainty lies in their setup.

Lev: For us on the hardware side, that means any drift or instability in the back scattering laser system will directly translate into an error in our final energy measurement for anything we try to calibrate.

Kai: So, basically, they’ve shown a successful way to get a tight number, but the next step is figuring out how to minimize that dependency on external calibrations.

Mira: That's what I think it means for the world right now—it validates this specific measurement technique as being robust for this type of particle.

Lev: It proves the methodology works, but it doesn't solve the fundamental problem of needing perfect energy control to get a result that is truly useful for real physics experiments.

E.P. Solodova, N.A. Petrovd R.R., Akhmetshina, A.N., Amirkhanova, A.V., Anisenkova, V.M., Aulchenkoa, N.S., Bashtovoya, D.E., Berkaeva,  Bondara A.E.,  Bragina A.V., ¡ Epifanova D.A., ∘ Epshteyna L.B., Erofeeva A.L., Fedotovicha G.V., Ignatova F.V., Ivanova D.R., Ivanova V.L., Karpova S.V., ¡ Kazanina V.F., ¡ Koopa I.A., ∘ Korobova A.A., Kozyreva A.N., Krokovnya P.P., Kuzmina A.S., Logashenkoa I.B., Lukina P.A., ¡ Mikhailova K.Yu, ¡ Obraztsova I.V., ∘ Otboeva A.V., Otboeva Yu, Pestova YuN, Perevedentseva E.A., Popova A.S., Rogovskya YuA, ¡ Rubana A.A., ¡ Ryskulov N.M., ∘ Ryzhenenkova A.E., Semenova A.V., Senchenkoa I.A, Shatunova YuM, Shebalina V.E., Shemyakina D.N., ¡ Shwartza B.A., ¡ Shwartze D.B., Timoshenko A.V., Titova V.M., Talysheva A.A., Tolmacheva S.S., Vorobiova A.I, Zemlyanskya I.M., Zhadana D.S., ¡ Yudina YuV, Navas S.¡ et al., Lysenko A.P., Koop I.A., Barkov L.¡ M., Koop I.A., Barkov L.¡ M., Zaitsev A.S., Lai A.∘ et al., Ambrosino F., Tomaradze A.∘ et al., Danilov V.V., Koop I.A., Abakumova V.¡ et al., Grancagnolo F.¡ et al., Anisyonkov A.V.¡ et al., Epifanov D., Akhmetshin R.R., Agostinelli S.∘ et al., Kuraev E.A., Arbuzov A.B.¡ et al., Achasov M.N., Abakumova V.¡ et al., Kozyrev E.A., , Budker Institute of Nuclear Physics, Novosibirsk State University, Novosibirsk State Technical University, Institute for Nuclear Research RAS Moscow, P-cure Ltd Shilat Israel

Budker Institute of Nuclear Physics SB RAS Novosibirsk Russia · Novosibirsk State University Novosibirsk Russia · Novosibirsk State Technical University Novosibirsk Russia · Institute for Nuclear Research RAS Moscow Russia · P-cure Ltd Israel

hep-ex

Submitted: 2026-06-15

Updated: 2026-10-31

Comments: 23 pages, 17 figures, 2 tables

License: http://creativecommons.org/publicdomain/zero/1.0/

Importance score: 92/100

The gist: Using more than 600 thousand K0 S → π+π− decays from the e+e− → ϕ(1020) → K0SKO L reaction…

Key concepts

Edge Angle ($\psi_c$)
This is a specific angle measured between pions from the K0S -> pi+pi- decay. The formula used to calculate it relates this angle to the kaon mass and pion momenta, allowing for the determination of the kaon's mass in this experiment.
Beam Energy Calibration
The precise energy of the electron beam is crucial. This measurement uses a calibration based on the world average phi-meson mass to control and correct for any systematic errors in beam energy, which is identified as the largest source of uncertainty.
Monte Carlo (MC) Simulation
GEANT4 simulations are heavily used to model how particles interact with the detector. These simulations help correct for detector response effects and use the world-average kaon mass as an input to accurately predict signal events.

Terminology

Summary

Using more than 600 thousand K0 S → π+π− decays from the e+e− → ϕ(1020) → K0SKO L reaction, the neutral kaon mass has been measured with the CMD-3 detector at the VEPP-2000 collider m(K O S) = 497. p. 0

Where the paper says it

Yudina,b aBudker Institute of Nuclear Physics, SB RAS, Novosibirsk, 630090, Russia bNovosibirsk State University, Novosibirsk, 630090, Russia cNovosibirsk State Technical University, Novosibirsk, 630092, Russia d Institute for Nuclear Research, RAS, Moscow, 117312, Russia eP-cure Ltd, Shilat, 7318800, Israel Abstract: Using more than 600 thousand K0 S → π +π − decays from the e +e − → ϕ(1020) → K0 SK0 L reaction, the neutral kaon mass has been measured with the CMD-3 detector at the VEPP-2000 collider. Using the beam energies control by the back-scattering laser light photons, and a calibration to the world average ϕ-meson mass, the neutral kaon mass is determind to be m(K0 ) = 497.

587 ± 0.012 MeV/c squared, where the first uncertainty is statistical, the second is systematic, and the third is the uncertainty from the energy calibration. p. 0
Where the paper says it

009(calibr. ) MeV/c 2 , where the first uncertainty is statistical, the second is systematic, and the third is the uncertainty from the energy calibration.

p. 0
Where the paper says it

009(calibr. ) MeV/c 2 , where the first uncertainty is statistical, the second is systematic, and the third is the uncertainty from the energy calibration.

Measurement Methodology

The neutral kaon mass was determined using a method based on measuring an opening angle between pions from the K0 S → π+π− decay, which is called the edge angle, ψc m(K0 S) = r E squared K0 S sin squared ψc squared + 4m squared π cos squared ψc squared. This method utilizes the beam energies controlled by the back-scattering laser light photons and a calibration to the world average ϕ-meson mass. p. 0

Where the paper says it

Yudina,b aBudker Institute of Nuclear Physics, SB RAS, Novosibirsk, 630090, Russia bNovosibirsk State University, Novosibirsk, 630090, Russia cNovosibirsk State Technical University, Novosibirsk, 630092, Russia d Institute for Nuclear Research, RAS, Moscow, 117312, Russia eP-cure Ltd, Shilat, 7318800, Israel Abstract: Using more than 600 thousand K0 S → π +π − decays from the e +e − → ϕ(1020) → K0 SK0 L reaction, the neutral kaon mass has been measured with the CMD-3 detector at the VEPP-2000 collider. Using the beam energies control by the back-scattering laser light photons, and a calibration to the world average ϕ-meson mass, the neutral kaon mass is determind to be m(K0 ) = 497.

The detector's tracking system provides momentum, angles, and dE/dX for charged tracks 4. Signal events selection> At the first stage of selection, exactly two oppositely charged good tracks are required with specific criteria regarding hits in the DC and polar angle.

Kinematic Corrections and Simulation

The kaon energy is corrected by convoluting the resonance curve with a Gaussian distribution of the beam energy around its nominal Ec.m. energy The weighted c. p. 5

Where the paper says it

Therefore the average c. energy of the kaons, weighted with the resonance curve, is shifted from the measured Ec.

m. energy is shifted up to ±60 keV at the slopes, and this shift is half the difference ∆Eϕ. p. 6
Where the paper says it

003 MeV, taken as an estimate of the systematic uncertainty. The kaon energy is shifted by a half the presented difference, ∆Eϕ, and the used corrections are listed in table 1.

The analysis relies heavily on Monte Carlo (MC) simulation based on GEANT4 to model detector response The MC simulation uses the world-average kaon mass value as input for signal events. p. 3
Where the paper says it

To understand the detector response to the processes under study we use Monte Carlo (MC) simulation of our detector based on the GEANT4 [16] package, in which all simulated events pass the whole reconstruction and selection procedure. The MC simulation uses primary generator with matrix elements for the studied process, including soft photon radiation by the initial electron or positron [17, 18].

Radiative corrections to the edge angle are calculated by shifting the generated edge angle based on detector resolution effects

Systematic Uncertainty Analysis

The systematic uncertainties are summarized in Table 2, where the largest uncertainty comes from the beam energy calibration using the world average ϕ-meson mass The major systematic uncertainty is derived from this calibration constant ∆ESND = 0.0085 ± 0.009 MeV, which is listed in Table 2 (line 1). p. 6

Where the paper says it

003 MeV, taken as an estimate of the systematic uncertainty. The kaon energy is shifted by a half the presented difference, ∆Eϕ, and the used corrections are listed in table 1.

p. 6
Where the paper says it

003 MeV, taken as an estimate of the systematic uncertainty. The kaon energy is shifted by a half the presented difference, ∆Eϕ, and the used corrections are listed in table 1.

Other significant uncertainties include the energy spread at ϕ resonance and radiative effects, with the strong ψc fit correction contributing about 0.015÷0.100 MeV/c squared

Final Result and Comparison

The final neutral kaon mass is determined to be m(K O S) = 497.587 ± 0.012 MeV/c squared, with an overall uncertainty estimated as 0. p. 2

Where the paper says it

[5], allows one to use pions with any decay angles to calculate the kaon mass. This approach has been used by the CMD-2 Collaboration, reaching an overall systematic uncertainty of 24 keV/c2 .

0124 MeV/c squared This result is in good agreement with all high statistical experiments and has better accuracy. p. 4
Where the paper says it

If the measured energy deviates by more than 2σ from the average, the corresponding data are not included into analysis, like the first point in figure 1: less than one percent of the events are removed. As a result, each experimental point has the energy obtained by the averaging of the individual measurements with much smaller statistical accuracy compared to the 30 keV systematic uncertainty, declared in ref.

The precision of the measurement is dominated by the uncertainties in the energy measurements

References

[1] S. Navas et al. (Particle Data Group), Phys. p. 3

Where the paper says it

superconducting solenoid with a field of 1. The tracking system allows one to detect charged particle tracks with a minimum polar angle of about 0.

p. 3
Where the paper says it

superconducting solenoid with a field of 1. The tracking system allows one to detect charged particle tracks with a minimum polar angle of about 0.

Rev. D110, 030001 (2024) and 2025 update.

[2] A. P. Lysenko, I. A. Koop et al., Nucl. Instr. and Meth., A359 (1995) 419.

[3] L. M. Barkov at all, JETP Lett. 42 (1985) 138-141, Pisma Zh.Eksp.Teor.Fiz. 42 (1985) 113-116.

[4] L. M. Barkov at all, Yad.Fiz. 46 (1987) 1088-1094, Sov.J.Nucl.Phys. 46 (1987) 630.

[5] A. S. Zaitsev, (CMD-2 Collaboration), Frascati Phys. p. 2

Where the paper says it

1) The equation includes only the kaon energy (EK0 S well measured), the pion mass value (mπ very precisely known), and the edge angle. This method was used for the first time in the collider experiments by CMD collaboration [3, 4], and allowed to get the kaon mass with a few tens of keV/c2 .

Ser. 36 (2004) 467-471.

[6] A. Lai et al. (NA48 Collaboration), Phys. p. 2

Where the paper says it

1) The equation includes only the kaon energy (EK0 S well measured), the pion mass value (mπ very precisely known), and the edge angle. This method was used for the first time in the collider experiments by CMD collaboration [3, 4], and allowed to get the kaon mass with a few tens of keV/c2 .

Lett.B533 (2002) 196-206.

[7] F. Ambrosino et al., (KLOE Collaboration), JHEP 12 (2007) 073. p. 0

Where the paper says it

Prepared for submission to JHEP Neutral kaon mass measurement with the CMD-3 detector at VEPP-2000 E. Solodova,b,1 N.

p. 0
Where the paper says it

Prepared for submission to JHEP Neutral kaon mass measurement with the CMD-3 detector at VEPP-2000 E. Solodova,b,1 N.

[8] A. Tomaradze et al., Phys.Rev.D89 (2014) 3, 031501.

[9] V.V. Danilov et al., Proceedings EPAC96, Barcelona, p. p. 2

Where the paper says it

This approach has been used by the CMD-2 Collaboration, reaching an overall systematic uncertainty of 24 keV/c2 . The result was reported and appeared in a conference proceedings [5], but had not been published in a regular peer-reviewed journal.

p. 2
Where the paper says it

This approach has been used by the CMD-2 Collaboration, reaching an overall systematic uncertainty of 24 keV/c2 . The result was reported and appeared in a conference proceedings [5], but had not been published in a regular peer-reviewed journal.

1593 (1996); I.A. Koop, Nucl. Phys. B (Proc. Suppl.) 181-182 (2008) 371.

[10] V. Abakumova et al., Phys. Rev. Lett. 110 (2013) 140402.

[11] B.I. Khazin, Nucl. Phys. B (Proc. Suppl.) 181-182, (2008) 376.

[12] F. Grancagnolo et al., Nucl. Instr. Meth A623 (2010) 114.

[13] A.V. Anisyonkov et al., Nucl. Instr. Meth A598 (2009) 266.

[14] D. Epifanov (CMD-3 Collaboration), J. p. 2

Where the paper says it

1) The equation includes only the kaon energy (EK0 S well measured), the pion mass value (mπ very precisely known), and the edge angle. This method was used for the first time in the collider experiments by CMD collaboration [3, 4], and allowed to get the kaon mass with a few tens of keV/c2 .

Phys. Conf. Ser A293 (2011) 012009.

[15] R.R. Akhmetshin et al., Nucl. Phys B (Proc. Suppl.) 225-227 (2012) 69.

[16] S. Agostinelli et al. (GEANT4 Collaboration), Nucl. p. 3

Where the paper says it

The luminosity is measured using events of Bhabha scattering at large angles with about 1% accuracy [15]. To understand the detector response to the processes under study we use Monte Carlo (MC) simulation of our detector based on the GEANT4 [16] package, in which all simulated events pass the whole reconstruction and selection procedure.

Instr. Meth A506 (2003) 250.

[17] E.A. Kuraev and V.S. Fadin, Sov J Nucl Phys 41, (1985) 466; S. Actis et al., Eur Phys J C66 (2010) 585.

[18] A. B. Arbuzov et al. Eur.Phys.J C 46 (2006) 689-703.

[19] M. N. Achasov et al., Phys Part Nucl 56 (2025) 2, 405-411. p. 7

Where the paper says it

1) where η = (1 − Y 2 )/(1 + Y 2 ), Y = |p+|/|p−|, β 2 K0 S = 1 − (mK0 S /EK0 S ) 2 , β2 π = 1 − (2mπ/EK0 S ) 2 , EK0 S is the kaon energy, and ψ is the opening angle between the pions. The mass value in this equation depends on the kaon energy (assumed to be measured precisely), opening angle between pions, and the pion momenta ratio, Y ; in the ratio it is reasonable to assume that a significant part of the systematic uncertainties related to the momentum measurement cancels out.

p. 7
Where the paper says it

1) where η = (1 − Y 2 )/(1 + Y 2 ), Y = |p+|/|p−|, β 2 K0 S = 1 − (mK0 S /EK0 S ) 2 , β2 π = 1 − (2mπ/EK0 S ) 2 , EK0 S is the kaon energy, and ψ is the opening angle between the pions. The mass value in this equation depends on the kaon energy (assumed to be measured precisely), opening angle between pions, and the pion momenta ratio, Y ; in the ratio it is reasonable to assume that a significant part of the systematic uncertainties related to the momentum measurement cancels out.

[20] E. A. Kozyrev et al., Phys Lett B760 (2016) 314-319.

[21] Table 2. p. 4

Where the paper says it

energy spreads, δEc. , derived from the SND paper [19], are listed in table 1.

p. 4
Where the paper says it

energy spreads, δEc. , derived from the SND paper [19], are listed in table 1.

Summary of the systematic uncertainties study for the K0 S mass measurement

Summary of Findings

The neutral kaon mass is determined to be m(K O S) = 497.587 ± 0.012 MeV/c squared, where the first uncertainty is statistical, the second is systematic, and the third is the uncertainty from the energy calibration. The largest uncertainty comes from beam energy calibration using the world average ϕ-meson mass Two major corrections are applied: -0. p. 0

Where the paper says it

Yudina,b aBudker Institute of Nuclear Physics, SB RAS, Novosibirsk, 630090, Russia bNovosibirsk State University, Novosibirsk, 630090, Russia cNovosibirsk State Technical University, Novosibirsk, 630092, Russia d Institute for Nuclear Research, RAS, Moscow, 117312, Russia eP-cure Ltd, Shilat, 7318800, Israel Abstract: Using more than 600 thousand K0 S → π +π − decays from the e +e − → ϕ(1020) → K0 SK0 L reaction, the neutral kaon mass has been measured with the CMD-3 detector at the VEPP-2000 collider. Using the beam energies control by the back-scattering laser light photons, and a calibration to the world average ϕ-meson mass, the neutral kaon mass is determind to be m(K0 ) = 497.

030÷0.034 MeV/c squared for the beam energy spread and 0. p. 4
Where the paper says it

Figure 1 shows a screenshot from the energy monitor presenting the data-taking history for the Ebeam=509. Each point corresponds to the beam energy and the energy spread values, obtained from the back-scattered-photon energy spectrum fit as described in ref.

015÷0.100 MeV/c squared for the radiative effects. p. 9
Where the paper says it

We check the procedure by applying it to the "true” open angles of the pions from the primary generator, and obtain the dark points in figure 4(c) which form a sharp narrow structure exactly at the ψ 0 c edge angle value. Note that for the generator angles there are no points below the ψ 0 c value, but large angles are allowed, because the radiative effects decrease the kaon energy.

The overall uncertainty in our measurement is estimated as 0. p. 2
Where the paper says it

[5], allows one to use pions with any decay angles to calculate the kaon mass. This approach has been used by the CMD-2 Collaboration, reaching an overall systematic uncertainty of 24 keV/c2 .

0124 MeV/c squared. p. 6
Where the paper says it

The triangle (blue) markers show the obtained corrections if we use the ϕ width value from the PDG [1]. The calculation with parameters from the SND measurement [19] are shown by the open squared (pink) markers.

Detailed Uncertainty Breakdown

The systematic uncertainties are summarized in Table 2, where the largest uncertainty comes from the beam energy calibration using the world average ϕ-meson mass The major systematic uncertainty is derived from this calibration constant ∆ESND = 0.0085 ± 0.009 MeV, which is listed in Table 2 (line 1). Other significant uncertainties include the energy spread at ϕ resonance and radiative effects, with the strong ψc fit correction contributing about 0.015÷0.100 MeV/c squared

Correction Procedures

The analysis employs several procedures to correct for systematic effects, including:

  1. Beam energy control using the Back-Scattering-Laser-Light system

  2. Kaon energy corrections by convoluting the resonance curve with the Gaussian distribution of the beam energy around its nominal Ec. p. 5

    Where the paper says it

    Using the Ec. energy spread from table 1 and the ϕ-meson parameters we convolute the resonance curve with the Gaussian distribution of the beam energy around nominal Ec.

    m. energy

  3. Edge angle corrections, which involve a procedure to minimize mean square deviation using weights according to ψ and LogY resolutions. p. 8

    Where the paper says it

    We develop a procedure which minimizes the mean square deviation (using weights according to the ψ and LogY resolutions) of a given experimental point on the two-dimentional distribution in figure 4(b) from the point on the curve, and calculates a length, LLogY, of the curve segment from LogY=0 to the determined optimal point (with sign) in the units of LogY. A "modified opening angle" for each measurement is calculated as a sum of the deviation value and the ψ 0 c value.

  4. Radiative corrections to the edge angle, which are calculated by shifting the generated edge angle based on detector resolution effects

  5. Angle corrections for pion angles, which involve testing events from e+e− → ϕ → π+π−π0 reaction

Comparison with Other Measurements

Figure 17 shows our result in comparison with the other K0 mass measurements. Our result is in good agreement with all high statistical experiments and has better accuracy. p. 4

Where the paper says it

If the measured energy deviates by more than 2σ from the average, the corresponding data are not included into analysis, like the first point in figure 1: less than one percent of the events are removed. As a result, each experimental point has the energy obtained by the averaging of the individual measurements with much smaller statistical accuracy compared to the 30 keV systematic uncertainty, declared in ref.

The small difference of 0. p. 5
Where the paper says it

We check also how large is the energy shift if we vary the ϕ-meson parameters or the energy spread value. The difference of the weighted c.

001 MeV/c squared, listed in table 2 line 9), indicates a strong cancellation of angular uncertainties when averaging over the “fish” and “bird” event types. p. 6
Where the paper says it

The kaon energy is shifted by a half the presented difference, ∆Eϕ, and the used corrections are listed in table 1. 4 Signal events selection We select events of the e +e − → ϕ → K0 SK0 L reaction, where the neutral kaon candidate is reconstructed from the K0 S → π +π − decay to obtain a clean event sample for the mass measurement.

[1] S. Navas et al. (Particle Data Group), Phys. Rev. D110, 030001 (2024) and 2025 update.

[2] A. P. Lysenko, I. A. Koop et al., Nucl. Instr. and Meth., A359 (1995) 419.

[3] L. M. Barkov at all, JETP Lett J 42 (1985) 138-141, Pisma Zh Eksp Teor Fiz. 42 (1985) 113-116.

[4] L. M. Barkov at all, Yad Fiz. 46 (1987) 1088-1094, Sov J Nucl Phys. 46 (1987) 630.

[5] A. S. Zaitsev, (CMD-2 Collaboration), Frascati Phys Ser. p. 2

Where the paper says it

1) The equation includes only the kaon energy (EK0 S well measured), the pion mass value (mπ very precisely known), and the edge angle. This method was used for the first time in the collider experiments by CMD collaboration [3, 4], and allowed to get the kaon mass with a few tens of keV/c2 .

36 (2004) 467-471.

[6] A. Lai et al. (NA48 Collaboration), Phys Lett B533 (2002) 196-206. p. 2

Where the paper says it

1) The equation includes only the kaon energy (EK0 S well measured), the pion mass value (mπ very precisely known), and the edge angle. This method was used for the first time in the collider experiments by CMD collaboration [3, 4], and allowed to get the kaon mass with a few tens of keV/c2 .

[7] F. Ambrosino et al., (KLOE Collaboration), JHEP 12 (2007) 073.

[8] A. Tomaradze et al., Phys.Rev.D89 (2014) 3, 031501.

[9] V.V. Danilov et al., Proceedings EPAC96, Barcelona, p.1593 (1996); I.A. Koop, Nucl Phys B (Proc Suppl.) 181-182 (2008) 371.

[10] V. Abakumova et al., Phys. Rev. Lett J 110 (2013) 140402.

[11] B.I. Khazin, Nucl Phys B (Proc Suppl.) 181-182, (2008) 376.

[12] F. Grancagnolo et al., Nucl Instr Meth A623 (2010) 114.

[13] A.V. Anisyonkov et al., Nucl Instr Meth A598 (2009) 266.

[14] D. Epifanov (CMD-3 Collaboration), J Phys Conf Ser A293 (2011) 012009. p. 2

Where the paper says it

1) The equation includes only the kaon energy (EK0 S well measured), the pion mass value (mπ very precisely known), and the edge angle. This method was used for the first time in the collider experiments by CMD collaboration [3, 4], and allowed to get the kaon mass with a few tens of keV/c2 .

[15] R.R. Akhmetshin et al., Nucl Phys B (Proc Suppl.) 225-227 (2012) 69.

[16] S. Agostinelli et al. (GEANT4 Collaboration), Nucl Instr Meth A506 (2003) 250. p. 3

Where the paper says it

The luminosity is measured using events of Bhabha scattering at large angles with about 1% accuracy [15]. To understand the detector response to the processes under study we use Monte Carlo (MC) simulation of our detector based on the GEANT4 [16] package, in which all simulated events pass the whole reconstruction and selection procedure.

[17] E.A. Kuraev and V.S. Fadin, Sov J Nucl Phys 41, (1985) 466; S. Actis et al., Eur Phys J C66 (2010) 585.

[18] A. B. Arbuzov et al. Eur.Phys.J C 46 (2006) 689-703.

[19] M. N. Achasov et al., Phys Part Nucl 56 (2025) 2, 405-411.

[20] E. A. Kozyrev et al., Phys Lett B760 (2016) 314-319.

[21] Table 2.

Green — the paper says it, and the page is printed. Red — no passage carries it, so treat that sentence as unverified. The same check runs on your own text: check a summary against its source, $5.

Improvements for AI systems

  1. Beam energy control improvement: The system can use continuous beam energy monitoring via a back-scattering laser light system to ensure beam energies are maintained within ±2 sigma of nominal values, as described in Section 3.1.

  2. Kaon mass determination accuracy: The improved system will determine the neutral kaon mass with an overall uncertainty of 0.0124 MeV/c squared by applying corrections for energy calibration, beam energy spread, radiative effects, and angle corrections simultaneously.

  3. Edge angle extraction refinement: The system can implement a procedure that minimizes the mean square deviation of experimental points from the curve in figure 4(b) to calculate a modified opening angle for each measurement.

  4. Momentum correction integration: The system will correct each reconstructed pion momentum according to the second order polynomial fit function shown in figure 6(a) to remove large deviations caused by ionization energy loss in detector material.

  5. Azimuthal angle correction application: The system can correct the azimuthal angles of each positive and negative pion track using profiles from figure 10 to calculate modified opening angles, improving the edge angle determination by up to a half of milliradian for fish-bird type events.

  6. Systematic uncertainty management: The improved system will explicitly manage systematic uncertainties by accounting for energy calibration uncertainty (0.0085 MeV/c 2), energy spread shifts (-0.030 to +0.034 MeV/c 2), and radiative corrections (up to 1 mrad) in the final mass calculation.

  7. High-precision measurement capability: The system can achieve a final neutral kaon mass measurement of 497.587 +/- 0.004(stat.) +/- 0.008(syst.) +/- 0.009(calibr.) MeV/c squared, providing better accuracy than previous measurements like CMD-2 or CLEO-c '14.

Abstract

Using more than 600 thousand K S 0 toπ+π- decays from the e+e-toϕ(1020) to K S 0K L 0 reaction, the neutral kaon mass has been measured with the CMD-3 detector at the VEPP-2000 collider. Using the beam energies control by the back-scattering laser light photons, and a calibration to the world average ϕ-meson mass, the neutral kaon mass is determind to be m(K 0) = 497.587 plus or minus 0.004(stat.) plus or minus 0.008(syst.) plus or minus 0.009(calibr.), where the first uncertainty is statistical, the second is systematic, and the third is the uncertainty from the energy calibration.

Related papers