Low-energy nuclear recoil calibration of the LUX-ZEPLIN experiment with a photoneutron source
summary
The gist
The LZ experiment is a liquid xenon time-projection chamber (TPC) searching for evidence of particle dark matter interactions…
In short
The LZ experiment conducted its first calibration using an 88Y-9Be photoneutron source to study low-energy nuclear recoils, mimicking signals from solar neutrinos. The experiment successfully observed elastic nuclear recoils at 152 keV and 950 keV energies, providing direct evidence of LZ's sensitivity for detecting dark matter and neutrino interactions.
Key concepts
- Photoneutron Source (YBe)
- An 88Y-9Be source is used to create photoneutrons when gamma rays interact with beryllium. This source emits specific neutrons with energies of 152 keV and 950 keV, which are crucial for calibrating the detector's response to low-energy nuclear recoils.
- Elastic Nuclear Recoils
- These are events where a xenon nucleus is struck by a neutron, causing it to recoil at low kinetic energies. Observing these specific recoils allows researchers to tune the detector's ability to measure small energy depositions, which is vital for searching for dark matter signals.
- Charge-Yield (Qy)
- Qy is a parameter derived from the measured ionization signal (S2) and scintillation light (S1) in liquid xenon. Calibrating Qy accurately helps researchers convert the observed energy into a precise measurement of the nuclear recoil energy, essential for interpreting experimental results.
Terminology used across episodes
This episode discusses
- Low-energy nuclear recoil calibration of the LUX-ZEPLIN experiment with a photoneutron source · Paper Radio
- First Dark Matter Search Results from the LUX-ZEPLIN (LZ) Experiment
- Snowmass2021 Cosmic Frontier Dark Matter Direct Detection to the Neutrino Fog
- Projected WIMP sensitivity of the LUX-ZEPLIN (LZ) dark matter experiment
- Low-energy (0.7-74 keV) nuclear recoil calibration of the LUX dark matter experiment using D-D neutron scattering kinematics
- Nuclear Recoil Calibration at Sub-keV Energies in LUX and Its Impact on Dark Matter Search Sensitivity
- Low-Energy Nuclear Recoil Calibration of XENONnT with a 88 YBe Photoneutron Source
- XENONnT WIMP Search: Signal & Background Modeling and Statistical Inference
- Applications of an Y-88/Be photo-neutron calibration source to Dark Matter and Neutrino Experiments
- The Design, Implementation, and Performance of the LZ Calibration Systems
- A reanalysis of radioisotope measurements of the 9 Be (gamma,n) 8 Be cross-section
- The LUX-ZEPLIN (LZ) Experiment
- Background Determination for the LUX-ZEPLIN (LZ) Dark Matter Experiment
- Dark Matter Search Results from 4.2 Tonne-Years of Exposure of the LUX-ZEPLIN (LZ) Experiment
- A search for new physics in low-energy electron recoils from the first LZ exposure
- Simulations of Events for the LUX-ZEPLIN (LZ) Dark Matter Experiment
- Investigation of background electron emission in the LUX detector
- A Review of Basic Energy Reconstruction Techniques in Liquid Xenon and Argon Detectors for Dark Matter and Neutrino Physics Using NEST
- Importance of upgraded energy reconstruction for direct dark matter searches with liquid xenon detectors
- A Review of NEST Models for Liquid Xenon and Exhaustive Comparison to Other Approaches
- Measurement of the ionization yield from nuclear recoils in liquid xenon between 0.3 -- 6 keV with single-ionization-electron sensitivity
The paper
Low-energy nuclear recoil calibration of the LUX-ZEPLIN experiment with a photoneutron source · Read on arXiv
J. Aalbers, D.S. Akerib, A.K. Al Musalhi, F. Alder, C.S. Amarasinghe, A. Ames, T.J., Anderson, N., Ángelides, Árྚjo, Ármstronghi, ⌺ Alder, C.S. Amarasinghe, A. Ames
SLAC National Accelerator Laboratory · Kavli Institute for Particle Astrophysics and Cosmology at Stanford University · University College London Department of Physics and Astronomy at University College London · University of California, Santa Barbara Department of Physics at University of California, Santa Barbara · Imperial College London Physics Department at Imperial College London · University of Maryland Department of Physics at University of Maryland · King’s College London Department of Physics at King’s College London · STFC Rutherford Appleton Laboratory (RAL) · Brown University Department of Physics at Brown University · University of Michigan Randall Laboratory of Physics at University of Michigan · University of Zurich Department of Physics at University of Zurich · Lawrence Berkeley National Laboratory (LBNL) in Berkeley, California · University of Wisconsin-Madison Department of Physics at University of Wisconsin-Madison · University College London Schoolénce and Astronomy at University College London · Pennsylvania State University Department of Physics and Astronomy at Pennsylvania State University · Royal Holloway, University of London Department of Physics at Royal Holloway, University of London · South Dakota Science and Technology Authority Sanford Underground Research Facility in Lead, South Dakota · Fermi National Accelerator Laboratory in Batavia, Illinois · University of Oxford Department of Physics at the University of Oxford · University of Bristol H.H. Wills Physics Laboratory at the University of Bristol · The University of Sydney Schoolénce and Astronomy at The University of Sydney · Brookhaven National Laboratory in Upton, New York · University of Massachusetts Department of Physics at the University of Massachusetts Amherst · University of Alabama Department of Physics and Astronomy at the University of Alabama Tuscaloosa · University of Texas at Austin Department of Physics at the University of Texas at Austin Austin
The LZ experiment is a liquid xenon time-projection chamber (TPC) searching for evidence of particle dark matter interactions. In the simplest assumption of elastic scattering, many dark matter models predict an energy spectrum which rises quasi-exponentially with decreasing energy transfer to a target atom. LZ has recently reported evidence for coherent elastic neutrino-nucleus scattering (CE ν NS) of 8 B solar neutrinos, a signal nearly identical to that expected from a dark matter particle with a mass of about 5.5 GeV/ c squared, which similarly produces nuclear recoil energies <5 keV nr. This analysis details the first in situ photoneutron calibration of the LZ detector, using a custom yttrium-beryllium source that produces quasi-monoenergetic neutrons. Elastic nuclear recoils from both the dominant 152 keV and the rare 950 keV photoneutron modes are observed at rates consistent with expectation. We report the ionization yield, and the corresponding scintillation yield inferred from it, at a mean detected recoil energy of 3.1 keV nr and a drift field of 193 V/cm. The measurement demonstrates the ability of LZ to detect nuclear recoils near threshold and provides an independent check on the detector-response framework underlying few-GeV dark-matter and 8 B CE ν NS searches.
DOI: 10.1103/f6nr-nkdz
Transcript
Introduction to the show: ident: Physics. The day in general physics: instruments, methods and results across the field.
Kai: We're looking at the paper: "Low-energy nuclear recoil calibration of the LUX-ZEPLIN experiment with a photoneutron source".
Paper summary: Kai: So, this paper, "Low-energy nuclear recoil calibration of the LUX-ZEPLIN experiment with a photoneutron source," is about using a custom eight eighty y nine be photoneutron source to calibrate the LUX-ZEPLIN experiment.
Mira: The main thesis is that this photoneutron mode offers a potentially unambiguous way to calibrate the low energy response of LZ, specifically probing the low energy nuclear recoil regime where eight beryllium solar neutrino signals are expected.
Kai: They describe using monoenergetic photoneutrons from a custom built YBe source, and they report observing both the dominant one five two keV neutron mode and a rare nine five zero keV neutron mode.
Lev: The setup involves deploying this source within the LZ detector, which is a liquid xenon time projection chamber nested inside two veto detectors: a liquid xenon skin detector and an outer scintillator detector.
Mira: They also presented additional data taken with the beryllium metal replaced by natural magnesium to try and quantify those eight eighty y gamma ray backgrounds in situ.
Kai: The overall goal of this work is to calibrate the charge yield, Qy, using a nuclear recoil light and charge yield analysis based on these observations about the spectra.
Lev: They focused their analysis on tuning the overall scale of Qy by fitting the YBe data in a specific sub region, which was defined as one five two c less than nine phd and log ten s two c less than three point three.
Mira: The results they found are that this dominant one five two keV neutron mode allowed for calibration of the charge yield, Qy, which they claim is in agreement with existing literature and the NEST model uncertainties.
Kai: But they also found a small discrepancy, saying the best fit Qy is twelve percent lower than the NEST model at three point one kiloelectron nuclear recoil energy of three point one kiloelectron nuclear recoil.
Conclusion: Kai: So, to wrap up, this paper establishes that LZ has done something pretty important by successfully observing these low energy nuclear recoils from a photoneutron source.
Mira: The authors are J Aalbers and his team, and the implication is that this provides direct evidence that LZ can observe nuclear recoils from low mass dark matter interactions and those continuous neutrino interactions from eight beryllium solar neutrinos.
Lev: From an engineering standpoint, it confirms that the detector's response to these specific low energy events matches what we expect when we look at real hardware running on the NEST model.
Kai: It also shows them exactly where their calibration is sensitive, defined by that minimum recoil energy and that four point six kiloelectron nuclear recoil endpoint of the one five two keV photoneutron recoil.
Mira: This calibration gives them a solid number for Qy, which is crucial for any future dark matter search or neutrino signal analysis using this detector.
Lev: The limitation they mentioned is that future calibrations would benefit from longer exposures of both YBe and YMg sources to increase the level of statistics.
Kai: And they also flagged that reducing the detector energy threshold by including two fold S one signals is something that’s challenging right now because of accidental coincidence backgrounds.
Mira: So, in short, this work provides a positive identification of these photoneutron events, which validates the experiment's sensitivity to those specific low energy physics interactions.
More episodes
- 2610.34250-Yb/Sr optical clock comparison at 2.08E-18 uncertainty over a 1350-km fiber link
- 2610.36514-Integer electron-count cuts in variational second-order reduced-density-matrix theory. I. Molecular dissociation with fixed real-space and orbital partitions
- 2611.14082-Two atoms with strong light-induced dipolar interactions
- 2611.14040-Characterization of BNLs 20 and 30 micrometer thick LGADs for the Electron Ion Collider
- 2611.13399-Lift-element-based dynamic network of vortex gust-airfoil interactions
- 2611.13476-Hopfion Superlattices in 3D Twisted Moir'e Light Fields
- 2611.13642-Investigation of the timing performance of double-sided p-type 3D silicon sensors produced by CNM
- 2611.13830-SiPM optical readout of a PICOSEC Micromegas precise timing detector
- 2611.14152-Where are the shortest-path nodes in spatial networks?
- 2611.14219-Sub-Ice: semi-automated mapping of basal channels from ice shelf surface elevation data