SiPM optical readout of a PICOSEC Micromegas precise timing detector
summary
The gist
SiPM-based optical readout as a novel technique for PICOSEC Micromegas detectors allows for dual-readout of electronic and optical signals to achieve precise timing and spatial resolution Detector…
In short
PICOSEC Micromegas detectors use a combination of electronic and optical signals for precise measurements. Optical readout, achieved by integrating SiPMs to detect scintillation light from UV conversion, allows for dual-readout of timing and spatial information. This enables sub-20 ps timing resolution and millimetre-scale position reconstruction, improving particle identification and interaction analysis.
Key concepts
- PICOSEC Micromegas Detectors
- These are detectors that combine a Cherenkov radiator with a semi-transparent photocathode and a two-stage gaseous amplification structure. They are designed to provide precise timing for charged particles, which is crucial for time-of-flight measurements and particle identification.
- Optical Readout
- This technique involves embedding a solid wavelength shifter into the glass Micromegas to convert ultraviolet scintillation light into visible light. This visible light can then be detected by an array of SiPMs, providing an optical signal that complements the electronic readout.
- SiPM Array Reconstruction
- By using multiple SiPM channels, event positions are reconstructed using center-of-gravity methods based on the signal amplitudes. This provides a spatial resolution of 1.25 mm, which is compared against external tracking telescope data for detailed position analysis.
- Dual Readout Modes
- The system can operate in two modes: electronic readout and optical readout. Optical readout offers lower timing resolution but enables spatial reconstruction via light signals, while electronic readout provides high timing precision through induced signals.
Terminology used across episodes
This episode discusses
- SiPM optical readout of a PICOSEC Micromegas precise timing detector · Paper Radio
- A large area 100 channel Picosec Micromegas detector with sub 20 ps time resolution
The paper
SiPM optical readout of a PICOSEC Micromegas precise timing detector · Read on arXiv
F.M. Brunbauer, R. Aleksan, S. Aune, J. Bortfeldt, A. Breskin, M. Brunoldięe J., §G Fanourakis h K J Floethner a i M Gallinaro j F Garcia k I Giomataris b F Guerra l D Janssens m E Jelinkova a n A Kallitsopoulou b I Karakoulias o M Kovacic p P Legou b M Lisowska a J Liu q M Lupberger i r D J G Marques a H Muller r E Oliveri a T Papaevangelou b M Pomorski s L Ropelewski a D Sampsonidis o t T Schneider a B Schoenfelder u E Scorsone s M van Stenis Y Tsipolitis v S Tzamarias o t A Utrobicic w I Vai e f R Veenhof a P Vitule e f X Wang q S White a x D Zavazieva y Z Zhang q Y Zhou q, orgs_list_derived_from_affiliations
European Organization for Nuclear Research (CERN) · IRFU CEA Université Paris-Saclay · Department for Medical Physics Ludwig Maximilian University of Munich · Weizmann Institute of Science · Dipartimento di Fisica Università di Pavia · INFN Sezione di Pavia · Department of Physics and Astronomy Stony Brook University · Institute of Nuclear and Particle Physics NCSR Demokritos GR-15341 Agia Paraskevi Attiki Greece Helmholtz-Institut für Strahlen- und Kernphysik University of Bonn · Laboratório de InstrumentacΣo e Física Experimental de Particulas Lisbon Portugal · Helsinki Institute of Physics University of Helsinki · Department of Physics University of Turin · Inter-University Institute for High Energies Université libre de Bruxelles CP 230 Brussels Belgium · Czech Technical University in Prague Jugoslāvskǡ partyzánִ 1580/3 Praha 6-Dejvice Czechia · Department of Physics Aristotle University of Thessaloniki University Campus GR-54124 Thessaloniki Greece · University of Zagreb Faculty of Electrical Engineering and Computing Zagreb Croatia · State Key Laboratory of Particle Detection and Electronics University of Science and Technology China
Transcript
Introduction to the show: ident: Physics. The day in general physics: instruments, methods and results across the field.
Kai: We're looking at the paper: "SiPM optical readout of a PICOSEC Micromegas precise timing detector".
Title and authors: Kai: So we're diving into the title and authors of this paper, "SiPM optical readout of a PICOSEC Micromegas precise timing detector."
Mira: It sounds very specific—it’s about combining SiPMs with PICOSEC glass Micromegas to get better timing.
Lev: The authors are a big group, which is common in these large experimental collaborations, and you have to remember that this work is building on the PICOSEC concept of combining a Cherenkov radiator with a semi-transparent photocathode and two-stage gaseous amplification >
Kai: Exactly. The title tells us they’re looking at optical readout, which is a novel technique they are introducing to improve what was already possible with electronic readout >
Mira: And what this means for the world is that we can now get both precise timing information from the electronic signals and millimetre-scale position resolution from the optical signals >
The paper's summary: Kai: So, in terms of what they did, they describe how they integrated a solid wavelength shifter into the glass Micromegas to convert ultraviolet scintillation light into visible light so it can be detected by those SiPMs >
Mira: And that allows them to maximize the scintillation light output while still being able to read out the anode electronically via a transparent indium tin oxide anode >
Lev: The summary points out that timing performance of glass Micromegas in optical readout mode is compared and they achieved less than one hundred fifty picoseconds time resolution by optically read out scintillation light signals > <ref:2611.13830#pg2,by optically read out scintillation light signals>
Kai: And on top of that, they show the achievable spatial resolution from centre-of-gravity reconstruction of event positions from the amplitudes of signals on multiple SiPM channels is sigma equals one point two five millimetre >
The paper's improvements: Mira: They are suggesting that this dual-readout capability demonstrates the possibility of dual-readout of PICOSEC glass Micromegas: electronic signals and optical signals >
Kai: And they show this capability by comparing the time resolution with optical readout against the electronic one, finding that it's lower because of the slow scintillation mechanism or the decay time of a wavelength shifter >
Lev: They also showed that subtracting the electronic time resolution from the one obtained with SiPM readout results in an additional jitter of approximately one hundred ten picoseconds from the optical readout chain >
Mira: Plus, they found that fixed threshold timing with time walk correction performed better than a CFD algorithm on the SiPM waveforms when using lower threshold values, giving them the best resolution values >
Conclusion: Kai: So wrapping up this paper, the main implication is that we can use combined optical and electronic readout of PICOSEC Micromegas precise timing detectors to obtain tens of picoseconds timing resolution and millimetre-scale position resolution >
Mira: This capability lets us couple a SiPM array to a PICOSEC glass Micromegas enables readout of scintillation light produced during avalanche multiplication, and they achieved high light yield in the ne CF4 C2H6 gas mixture with the use of tetraphenyl butadiene as the wavelength shifter on the anode >
Lev: They also demonstrated that a camera-based readout is another avenue for position reconstruction, which may enable fine position reconstruction for events with a large number of photoelectrons >
Kai: So overall, this paper shows that combining optical and electronic readout of PICOSEC Micromegas precise timing detectors can be used to obtain tens of picoseconds timing resolution and millimetre-scale position resolution >
Mira: It’s a solid piece of work showing how you can use these combined signals for better event reconstruction >
Lev: I think it points toward needing faster scintillating mixtures or wavelength shifters because the paper noted that the slow scintillation time characteristics of CF4 or the decay time of the wavelength shifter are factors causing worse timing resolution with optical readout >
More episodes
- 2611.14082-Two atoms with strong light-induced dipolar interactions
- 2611.14040-Characterization of BNLs 20 and 30 micrometer thick LGADs for the Electron Ion Collider
- 2611.13399-Lift-element-based dynamic network of vortex gust-airfoil interactions
- 2611.13476-Hopfion Superlattices in 3D Twisted Moir'e Light Fields
- 2611.13642-Investigation of the timing performance of double-sided p-type 3D silicon sensors produced by CNM
- 2611.14152-Where are the shortest-path nodes in spatial networks?
- 2611.14219-Sub-Ice: semi-automated mapping of basal channels from ice shelf surface elevation data
- 2611.16341-SUMNO: Spatially Unrolled Multigrid Neural Operator for Fluid Flow Surrogates
- 2611.16090-Multi-UTE Myelin Fraction Mapping: Repeatability and Cross-Field-Strength Reproducibility at 1.5T and 3T
- 2611.14474-Thin-film lithium niobate integrated photonics at 493 nm