Continuous 3-D Latent Diffusion for Medical Image Generation and Reconstruction
summary
The gist
Continuous 3-D Latent Diffusion for Medical Image Generation and Reconstruction proposes a continuous 3-D latent diffusion model framework built on a coordinaterendering autoencoder (CoRe-AE) to…
In short
This framework proposes a continuous 3-D latent diffusion model to generate realistic medical images and reconstruct them from incomplete measurements. It uses a coordinatorendering autoencoder to work in a compressed latent space, allowing for efficient generation and reconstruction without overlapping sub-volumes.
Key concepts
- Continuous 3-D Latent Diffusion Model
- This is a diffusion model designed to generate high-resolution medical images by learning the underlying data distribution in a compact latent space. It works by iteratively refining random noise into meaningful image representations, enabling both new image creation and recovery from measurements.
- Coordinatorendering Autoencoder (CoRe-AE)
- This is a specialized autoencoder used to compress 3D medical images into a lower-dimensional latent grid. The encoder reduces spatial resolution first, followed by standard convolutional blocks. This allows the model to operate efficiently in the latent space for generation and reconstruction.
- Measurement Guided Reconstruction
- This process uses incomplete data (measurements) to recover the full 3D image volume. The framework reformulates this problem in a latent space where it can be solved by modeling how measurements relate to the latent representation, enabling guided recovery.
Terminology used across episodes
This episode discusses
- Continuous 3-D Latent Diffusion for Medical Image Generation and Reconstruction · Paper Radio
- MAISI-v2: Accelerated 3D High-Resolution Medical Image Synthesis with Rectified Flow and Region-specific Contrastive Loss
- Bilevel Optimized Implicit Neural Representation for Scan-Specific Accelerated MRI Reconstruction
- LoFi: Neural Local Fields for Scalable Image Reconstruction
- Diff-INR: Generative Regularization for Electrical Impedance Tomography
- MedIL: Implicit Latent Spaces for Generating Heterogeneous Medical Images at Arbitrary Resolutions
- Diffusion Posterior Sampling for General Noisy Inverse Problems
- Prompt-tuning latent diffusion models for inverse problems
- TorchRadon: Fast Differentiable Routines for Computed Tomography
- Improving 2D Diffusion Models for 3D Medical Imaging with Inter-Slice Consistent Stochasticity
- Investigating Data Memorization in 3D Latent Diffusion Models for Medical Image Synthesis
- SANA: Efficient High-Resolution Image Synthesis with Linear Diffusion Transformers
- SANA-Video: Efficient Video Generation with Block Linear Diffusion Transformer
The paper
Continuous 3-D Latent Diffusion for Medical Image Generation and Reconstruction · Read on arXiv
Youness Mellak, Antoine De Paepe, Dimitris Visvikis, Alexandre Bousse
University of Brest · LaTIM · Inserm
High-resolution three-dimensional (3-D) medical latent diffusion remains limited by the cost of decoding full volumes, which existing latent autoencoders (AEs) handle through overlapping sub-volume decoding. We propose a continuous 3-D latent diffusion model framework for computed tomography (CT) and magnetic resonance imaging (MRI) generation and measurement-guided reconstruction, built on a coordinate-rendering autoencoder (CoRe-AE). Its decoder applies its convolutional stage once on the compact latent grid and renders voxel intensities from spatial coordinates through a lightweight implicit head, evaluated in memory-bounded chunks. This design avoids overlapping sub-volumes and remains differentiable with respect to the latent, so that the decoder can be used inside measurement-guided reconstruction. The framework was evaluated on CT volumes of 512 voxels and MRI volumes of 256 voxels. At 512, the decoder was 4--18 times faster than the MAISI and 3D MedDiffusion AEs and required the lowest peak graphics processing unit (GPU) memory, including when its gradient was computed. CoRe-AE also achieved the highest peak signal-to-noise ratio (PSNR) and structural similarity index (SSIM) among the evaluated AEs on both modalities. The resulting frozen 3-D latent prior generated full volumes without patch seams and, without retraining, reconstructed sparse-view CT and accelerated MRI through hard data consistency, within 2.4--4.9 dB PSNR of the pixel-domain decomposed diffusion sampler (DDS). A single volumetric latent prior thus supports both generation and reconstruction of high-resolution medical volumes on one GPU. Our code and pretrained weights are available at https://github.com/Mellak/continuous-3d-latent-diffusion.
Transcript
Introduction to the show: ident: Physics. The day in general physics: instruments, methods and results across the field.
Kai: I'm Kai.
Mira: And I'm Mira, here with Lev.
Kai: We're looking at the paper: "Continuous 3-D Latent Diffusion for Medical Image Generation and Reconstruction".
Mira: Here's the gist of the paper. Continuous 3-D Latent Diffusion for Medical Image Generation and Reconstruction proposes a continuous 3-D latent diffusion model framework built on a coordinaterendering autoencoder (CoRe-AE) to handle high-resolution medical image generation and measurement-guided reconstruction efficiently.
Kai: This design avoids overlapping sub-volumes and remains differentiable with respect to the latent, allowing the decoder to be used inside measurement guided reconstruction.
Mira: Framework Overview The framework addresses two tasks under constrained memory: generation of new realistic volumes from a learned data distribution p(x) and recovery of x from incomplete measurements y through the forward model A(x).
Kai: The problem is reformulated in the latent space Z by solving find z ∼ p(z) s.t.
Paper summary: Kai: So, wrapping up this talk on "Continuous three-D Latent Diffusion for Medical Image Generation and Reconstruction," we see a framework that uses a coordinaterendering autoencoder to generate images and reconstruct them from measurements in a way that avoids repeated dense sub-volume processing <ref:2607.16491#pg1,Continuous 3-D Latent Diffusion for Medical Image Generation and Reconstruction>. It achieves speed gains by factoring out the decoder passes rather than by making the model inherently smaller.
Mira: The authors are proposing this continuous latent diffusion model on top of their CoRe-AE, which allows them to use this same latent prior for both unconditional generation and reconstruction guided by measurements through a differentiable setup. This means the latent space is used as a shared representation across different tasks.
Lev: If you look at the title and the authors, it’s about moving towards continuous representations for volumetric medical data, which is where things are heading in this field. It’s about making these models practical for real-world clinical use, even if they still have that fidelity gap compared to pixel-domain solvers.
Kai: The implication is that we can now use these diffusion priors more directly inside reconstruction pipelines without having to constantly worry about the computational cost of decoding every single voxel in every step. It’s a structural improvement in how the model interacts with the measurement process.
Mira: Essentially, they are showing a path where you can generate realistic three dee medical volumes and then reconstruct them from incomplete data using this continuous latent diffusion method, provided you accept that iterative refinement still needs to close that gap to the highest possible fidelity <ref:2607.16491#pg1>.
Conclusion: Kai: So, we’ve been looking at this paper on continuous three dimensional latent diffusion for medical image generation and reconstruction. It’s about using a coordinaterendering autoencoder to make these tasks work without having to process huge chunks of data repeatedly.
Mira: Right, it frames the problem in the latent space and shows how you can use that same learned data distribution for both creating new images and fixing bad measurements. It's a shared representation across different problems.
Lev: From an engineering standpoint, avoiding those repeated dense sub volume passes is huge because each iteration in reconstruction has to do a full decoder pass with gradients, so cutting that down makes the whole thing much faster on real hardware.
Kai: The authors built this framework to handle generating realistic volumes and recovering them from incomplete measurements. They trained their autoencoder first, then used those learned latents for both generation and reconstruction guided by those measurements through a diffusion process.
Mira: It really shows how you can use the latent space as a bridge between creating something new from scratch and trying to fix data that’s already been collected but is missing pieces. That's a powerful connection for medical imaging.
Lev: The performance numbers they show, like the reconstruction being two point four to four point nine decibels below pixel domain solvers, tell us it’s not perfect yet, but it’s getting close enough for clinical consideration in some scenarios.
Kai: So the main thing here is making this continuous latent diffusion model practical enough to use directly inside measurement guided reconstruction pipelines without having those massive computational overheads we usually deal with.
Mira: It suggests a future where the diffusion model itself is baked into how we reconstruct medical images, not just used as a separate step after the initial image has been formed.
Lev: We’re still looking at how to push those results onto actual hardware and see if that speedup translates into something useful for real-time clinical applications.
More episodes
- 2611.14082-Two atoms with strong light-induced dipolar interactions
- 2611.14040-Characterization of BNLs 20 and 30 micrometer thick LGADs for the Electron Ion Collider
- 2611.13399-Lift-element-based dynamic network of vortex gust-airfoil interactions
- 2611.13476-Hopfion Superlattices in 3D Twisted Moir'e Light Fields
- 2611.13642-Investigation of the timing performance of double-sided p-type 3D silicon sensors produced by CNM
- 2611.13830-SiPM optical readout of a PICOSEC Micromegas precise timing detector
- 2611.14152-Where are the shortest-path nodes in spatial networks?
- 2611.14219-Sub-Ice: semi-automated mapping of basal channels from ice shelf surface elevation data
- 2611.16341-SUMNO: Spatially Unrolled Multigrid Neural Operator for Fluid Flow Surrogates
- 2611.16090-Multi-UTE Myelin Fraction Mapping: Repeatability and Cross-Field-Strength Reproducibility at 1.5T and 3T