BART Online Open-Source Sequence Toolbox for Computational MRI
summary
The gist
In this work, an end-to-end open-source framework for sequence design and model-based reconstruction based BART can be used to develop advanced qMRI techniques Online integration with a…
In short
BART is an open-source framework for designing MRI pulse sequences and model-based reconstruction. It allows users to develop advanced quantitative MRI techniques, including T1 and R*2 mapping, by defining sequences through events like gradients and RF pulses. The system enables online adjustment of sequence parameters via a vendor-specific driver while allowing exact offline reproduction using Pulseq files.
Key concepts
- BART Framework
- BART is an end-to-end open-source toolbox for computational MRI that allows users to develop pulse sequences. It supports quantitative MRI methods like T1 and R*2 mapping by defining sequences through a set of structured events, enabling the creation of complex imaging protocols from scratch.
- Online Acquisition Workflow
- For real-time imaging, BART is compiled as a dynamic library linked with a vendor-specific driver. This setup lets users adjust sequence parameters online using a vendor interface. Sequence events are computed just-in-time and converted into hardware instructions for immediate execution.
- Pulseq Export
- Sequences can be exported to Pulseq files, which are a widely used, vendor-neutral standard. This export enables the exact offline reproduction of the sequence using external software. This ensures that results obtained online can be verified by running the same sequence offline.
- Sequence Events
- MRI sequences are built from fundamental events: gradient events (describing magnetic field changes), RF pulses (defining excitation), sampling periods (ADC information), and wait/trigger events. These individual components are combined into blocks to form a complete imaging sequence.
Terminology used across episodes
This episode discusses
The paper
BART Online Open-Source Sequence Toolbox for Computational MRI · Read on arXiv
Institute of Biomedical Imaging, Graz University of Technology · Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital Department of Radiology · Department of Radiology, Harvard Medical School Department of Radiology German Centre for Cardiovascular Research Partner Site Göttingen BioTechMed-Graz
Purpose In advanced computational MRI techniques, acquisition and reconstruction techniques are jointly designed. For reproducibility, it is therefore important to provide an open implementation of both. At the same time, any use in a clinical environment usually requires a close integration with the MRI scanner. Ensuring long-time reproducibility and maintenance then poses additional challenges. In this work, we aim to provide a fully integrated open-source framework that can meet these demands. Methods A software framework to develop pulse sequences is added to BART, an open-source toolbox for computational MRI. In addition, a vendor-specific driver sequence is developed that can be used to run the sequence on a clinical MRI scanner enabling online adjustment of all relevant sequence parameters. Using the Pulseq format, the exact same sequence can also be reproduced offline using a widely used vendor-neutral open-source standard. Using the Pulseq format, the exact same sequence can also be reproduced offline. As proof-of-concept, quantitative MRI methods for T1 and joint water/fat R2*, B0 mapping using radial FLASH and model-based reconstruction are implemented in the proposed framework. Consistency between online and offline acquisition is validated in phantom and in vivo experiments. Results Quantitative MRI methods highlighting specific challenges of acquisition and reconstruction were successfully implemented in BART. Acquisition parameters and FOV can be adapted online on a clinical MRI system. Quantitative parameter maps from model-based reconstruction agree for online and offline regenerated Pulseq acquisitions. Conclusion This work enables reproducibility of advanced computational MRI methods within a comprehensive end-to-end open-source framework.
Transcript
Introduction to the show: ident: Physics. The day in general physics: instruments, methods and results across the field.
Kai: We're looking at the paper: "BART Online Open-Source Sequence Toolbox for Computational MRI".
Mira: Here's the gist of the paper. In this work, an end-to-end open-source framework for sequence design and model-based reconstruction based BART can be used to develop advanced qMRI techniques Online integration with a vendor-specific interpreter enables online adjustment of sequence parameters, while Pulseq export allows an exact offline reproduction of the sequence Framework Integration and Capabilities The paper introduces BART as an open-source toolbox for computational MRI and extends it to include a sequence development framework This integrated framework allows for the development of pulse sequences, including a vendor-specific driver sequence that enables online adjustment of all relevant sequence parameters Sequences can be exported to Pulseq files, which are used to reproduce the exact same sequence offline using a widely used vendor-neutral open-source standard The framework supports quantitative MRI methods for T1 and joint water/fat R∗2, B0 mapping using radial FLASH and model-based reconstruction as proof-of-concept Sequence Definition and Event Composition The specific configuration of an MRI sequence depends on a high-level parameter set comprising fixed system parameters as well as adjustable parameters Sequences are composed from different event types, namely gradient events, RF pulses, sampling (Analog-to-digital converter, ADC) periods, wait and trigger events Gradients are decomposed into triangles to describe their amplitude at midtime in phase-, read- and slice-encoding direction RF events include a pulse with flip angle, phase, frequency shift, and a mapping to a pulse shape ADC events are defined with a dwell-time and number of samples, as well as frequency and phase information A set of events is combined into a sequence block, which are classified into magnetic preparation or imaging blocks Online Acquisition Workflow For online acquisition, BART is compiled as a dynamic library and linked with a vendor-specific driver sequence that can interpret the generated sequence events The interface is designed in a generalized way to completely disentangle the actual sequence logic from the driver sequence Vendor-specific user interface (UI) parameters are mapped to sequence parameters using a generalized interface that also allows the definition of custom parameters During execution, sequence events are computed just-in-time and interpreted/converted to actual vendor-specific hardware instructions for every sequence block A log file containing a synthesized command-line is automatically saved each time a sequence is started for reproducibility Model-Based Reconstruction Validation Consistency between online and offline acquisition is validated in phantom and in vivo experiments by comparing the results when using the online driver sequence with results obtained when reproducing the acquisition using exported Pulseq files Quantitative parameter maps from model-based reconstruction agree for both online and offline regenerated Pulseq acquisitions The framework enables reproducibility of advanced computational MRI methods within a comprehensive end-to-end open-source framework Model-based reconstructions of a FLASH sequence utilizing 15 echoes show good agreement in the parameter maps for both R⋆2 and B0 maps between Pulseq and online measurements Good agreement between Pulseq and online acquisitions can be observed for both quantitative maps demonstrated by low differences across the whole brain Reproducibility and Maintenance The integration into the development workflow of the BART toolbox ensures long-term reproducibility and maintenance for sequences A continuous integration pipeline is used to automatically run tests when the software is changed to be able to identify and fix bugs early on The code to reproduce the results of this paper is available at https://gitlab.tugraz.at/ibi/mrirecon/papers/bart-sequence BART is available at https://codeberg.org/mrirecon/bart The Pulseq interpreter can be obtained from the University of Freiburg The BART Driver Sequence (BOOST: BART Online Open-Source Sequence Toolbox) can be obtained from the Graz University of Technology via Siemens Healthineers’ C2P platform An end-to-end open-source framework for sequence design and model-based reconstruction based BART can be used to develop advanced qMRI techniques Online integration with a vendor-specific interpreter enables online adjustment of sequence parameters, while Pulseq export allows an exact offline reproduction of the sequence Conflict of Interest The authors declare no competing interests Data Availability Statement In the spirit of reproducible research, the code to reproduce the results of this paper is available at https://gitlab.tugraz.at/ibi/mrirecon/bart-sequence BART is continuously being developed and maintained since 2013 The Institute of Biomedical Imaging at Graz University of Technology and BART developers are committed to supporting the toolbox in the future Acknowledgement This work has been supported by the DZHK (German Centre for Cardiovascular Research), funding code: 81Z0300115 This research was funded in 24 part by NIH under grant U24EB029240 This research was funded in whole or in part by the Austrian Science Fund (FWF) 10.55776/F100800 The authors thank the ISMRM Reproducible Research Study Group for conducting a code review of the code (Version 0.1) supplied in the Data Availability Statement This research was funded in whole or in part by the Austrian Science Fund (FWF) 10.55776/F100800 The authors thank the ISMRM Reproducible Research Study Group for conducting a code review of the code (Version 0.1) supplied in the Data Availability Statement The scope of the code review covered only the code’s ease of download, quality of documentation, and ability to run, but did not consider scientific accuracy or code efficiency The Institute of Biomedical Imaging at Graz University of Technology and BART developers are committed to supporting the toolbox in the future References
1: Stikov N, Trzasko JD, Bernstein MA.
Kai: Reproducibility and the future of MRI research.
Mira: Magnetic Resonance in Medicine 2019; 82:1981–1983
2: Knoll F, Zbontar J, Sriram A, et al.
Kai: fastMRI: A Publicly Available Raw k-Space and DICOM Dataset of Knee Images for Accelerated MR Image Reconstruction Using Machine Learning.
Paper summary: Kai: So to wrap up on "BART Online Open-Source Sequence Toolbox for Computational MRI," it’s this end-to-end open-source framework that lets you design sequences and reconstruct images using a model.
Mira: It claims that online integration with a vendor-specific interpreter allows you to adjust sequence parameters while acquiring data, and the Pulseq export lets you reproduce the exact same sequence offline using an open standard two <ref:2607.19099#pg1>.
Lev: The implication for users is that they get reproducibility of advanced computational MRI methods, which was a major challenge because pulse sequences are usually proprietary three <ref:2607.19099#pg1>.
Kai: It’s about creating a tool that meets those demands for long-time reproducibility and maintenance in clinical settings one <ref:2607.19099#pg1,long-time reproducibility and maintenance>.
Mira: Essentially, it gives researchers an open path to develop and share these complex techniques without being locked into one vendor's system two <ref:2607.19099#pg1>.
Conclusion: Kai: So we're wrapping up on this BART Open-Source Sequence Toolbox paper by Stikov and colleagues.
Mira: It’s about taking a whole framework for sequence design and model based reconstruction, and making it open source so everyone can use it.
Lev: The core idea is this end to end system that lets you build sequences and then reconstruct images using a model.
Kai: And the big thing they’re showing is how you can run that sequence online while also having a vendor specific tool adjust the parameters on the fly.
Mira: Plus, you get this Pulseq export file so you can take those exact parameters offline and reproduce the acquisition perfectly using a standard format.
Lev: So it’s about connecting the online adjustment capability with an offline reproduction capability for quantitative MRI.
Kai: It seems like they’re really focusing on making advanced computational MRI techniques reproducible without being locked into one specific machine setup.
Mira: They show this consistency in phantom and in vivo experiments when you compare the online acquisition results with the offline reconstruction using those exported Pulseq files.
Lev: For me, that validation is key because it means the model based reconstructions for things like T1 and joint water fat R star two B zero mapping actually agree between the two methods.
Kai: I mean, they even show good agreement in the parameter maps for both R star two and B zero maps when using a radial FLASH sequence with fifteen echoes.
Mira: It proves that this whole framework can reliably support quantitative MRI methods for T1 and joint water fat R star two B zero mapping.
Lev: It’s a solid proof of concept, but the real question is how much overhead this online dynamic library adds to the actual running time on real hardware.
Kai: That's what we need to look at next—the actual performance trade offs when you run this kind of online sequence generation.
More episodes
- 2611.14040-Characterization of BNLs 20 and 30 micrometer thick LGADs for the Electron Ion Collider
- 2611.13399-Lift-element-based dynamic network of vortex gust-airfoil interactions
- 2611.13476-Hopfion Superlattices in 3D Twisted Moir'e Light Fields
- 2611.13642-Investigation of the timing performance of double-sided p-type 3D silicon sensors produced by CNM
- 2611.13830-SiPM optical readout of a PICOSEC Micromegas precise timing detector
- 2611.14152-Where are the shortest-path nodes in spatial networks?
- 2611.14219-Sub-Ice: semi-automated mapping of basal channels from ice shelf surface elevation data
- 2611.16341-SUMNO: Spatially Unrolled Multigrid Neural Operator for Fluid Flow Surrogates
- 2611.16090-Multi-UTE Myelin Fraction Mapping: Repeatability and Cross-Field-Strength Reproducibility at 1.5T and 3T
- 2611.14474-Thin-film lithium niobate integrated photonics at 493 nm