Comparison of Methods for Extracting Three-Dimensional L'evy Source Parameters in sqrt s NN = 200 GeV Au+Au Collisions with EPOS3
Listen
Radio episode about this paper
Transcript
Introduction to the show: ident: Nuclear Theory. The day in nuclear theory: structure, reactions and the models behind them.
Kai: We're looking at the paper: "Comparison of Methods for Extracting Three-Dimensional L'evy Source Parameters in sqrt s NN = 200 GeV Au+Au Collisions with EPOS3".
Mira: Here's the gist of the paper. Bose–Einstein femtoscopy probes the spatiotemporal geometry of the particle-emitting source in heavy-ion collisions, where experimental data favor a L´evy-stable source description Comparison of Extraction Methods The paper compares four approaches for extracting 3D L´evy source parameters using π+π+ pairs from EPOS3-simulated Au+Au collisions at √sNN = 200 GeV The methods include direct fits to the pair-source distribution D(ρ), fits to the two-particle correlation function C(q) obtained via (i) the CRAB package, (ii) direct numerical integration of D(ρ), and (iii) fast Fourier transformation (FFT) While numerical integration and FFT are analytically identical and numerically equivalent on an identical momentum grid, FFT reduces the computation time from hours to seconds.
Kai: Source Parameter Extraction Details The analysis extracts the transverse-mass dependence of the L´evy radii, L´evy index α, and correlation strength λ in 0–10 % central collisions The three-dimensional symmetric L´evystable distribution is defined via its inverse Fourier transform as L(α, R2, x) = 1/(2π)3Z d3q e(i q·x) exp-1/2q T R2qa/2.
Mira: This distribution yields a correlation function C(0)2(qout, qside, qlong) = 1+λ exp - (q 2 outR 2 out + q 2 sideR 2 side + q 2 longR 2 long)/a/2.
Kai: This equation contains five physical parameters to be extracted in each KT interval: the correlation strength λ, the three L´evy radii Rout, Rside, Rlong, and the L´evy index α.
Paper summary: Kai: So to wrap up this paper "Comparison of Methods for Extracting Three-Dimensional L'evy Source Parameters in sqrt s NN = two hundred GeV Au+Au Collisions with EPOS3", the main finding is that the numerical integration FFT framework is a much faster and more consistent alternative to CRAB because it gives you smooth kinetic temperature dependencies without those fluctuations from pair sampling <ref:2611.08069#pg1,Comparison of Methods for Extracting Three-Dimensional L'evy Source Parameters in>.
Mira: It's important to remember that while both momentum space fits and direct coordinate space source fits show some systematic differences, these differences might just be due to comparing parameters averaged over events with fits to a source built by accumulating all the events.
Lev: The comparison shows that while both types of analysis are sensitive to different spatial and momentum regimes, those systematic differences could stem from comparing event averaged parameters with fits to an ensemble accumulated source.
Kai: So what does this mean for the world? It means that when we look at these femtoscopy measurements, we can't just rely on one specific method without considering how the source is being sampled or averaged over events.
Mira: The paper suggests that understanding these subtle effects of superposition of distributions is key to accurately mapping the spatiotemporal structure of where particles are emitted in heavy-ion collisions.
Conclusion: Kai: So we're wrapping up the discussion on this paper comparing methods for extracting three dimensional Lévy source parameters in gold into gold collisions at twenty zero GeV center of mass energy using EPOS three simulations.
Mira: Basically, they compared four different ways to pull out these source details like the Lévy index and correlation strength from particle data.
Lev: The main thing is that the numerical integration fast Fourier transform method is way faster and more consistent than the crab package because it avoids those fluctuations you get from sampling pairs randomly.
Kai: It sounds like they’re saying that when you use this FFT method, you get smoother kinetic temperature trends without those weird bumps caused by how they sampled the data.
Mira: Exactly. And even though there are these small systematic differences between fitting momentum space data versus direct coordinate space source fits, those discrepancies might just come from comparing event averages to a source built by accumulating all the events.
Lev: It suggests that understanding how different scales of Lévy distributions overlap is what creates those slightly lower effective indices when you try to fit everything with one single Lévy function.
Kai: So, the authors aren't just giving us one perfect number, they’re showing us the messy reality of fitting these sources depending on whether you look at them in momentum space or in physical coordinate space.
Mira: It means we have to be careful about which parameter set you trust based on what you're trying to measure.
Lev: And this whole comparison points toward needing a way to disentangle those effects, maybe by looking at individual events instead of just averages.
Department of Atomic Physics, ELTE ≙otvöos Lorand University
nucl-th
Submitted: 2026-11-05
Updated: 2026-11-05
Comments: 17 pages, 4 figures. Presented at the 18th Workshop on Particle Correlations and Femtoscopy, May 18-22, 2026, Budapest, Hungary
License: http://arxiv.org/licenses/nonexclusive-distrib/1.0/
Importance score: 83/100
The gist: Bose–Einstein femtoscopy probes the spatiotemporal geometry of the particle-emitting source in heavy-ion collisions…
Key concepts
- L'evy stable source description
- This is a mathematical model used to describe the shape of the particle-emitting region in heavy-ion collisions. It suggests that the spatial distribution of emitted particles follows a specific statistical pattern, which helps researchers understand how space and time are related during the collision process.
- Two-particle correlation function $C(q)$
- This function measures how pairs of particles are correlated in momentum space. By analyzing this correlation, researchers can extract information about the size and shape of the source, specifically its L'evy radii and index ($\alpha$), which define the geometry of where particles were created.
- Numerical integration/FFT framework
- This method involves directly working with the simulated ensemble-accumulated source data. It is computationally much faster than older methods like CRAB because it avoids random pair sampling, leading to smoother and more statistically reliable measurements of the source parameters.
- Systematic Discrepancies
- The study found consistent differences when comparing different ways of fitting the data, such as momentum-space fits versus direct coordinate-space fits. These differences might arise because fitting event averages doesn't perfectly match the underlying, ideal L'evy distribution shape.
Terminology
Summary
Bose–Einstein femtoscopy probes the spatiotemporal geometry of the particle-emitting source in heavy-ion collisions, where experimental data favor a L´evy-stable source description
Comparison of Extraction Methods
The paper compares four approaches for extracting 3D L´evy source parameters using π+π+ pairs from EPOS3-simulated Au+Au collisions at √sNN = 200 GeV The methods include direct fits to the pair-source distribution D(ρ), fits to the two-particle correlation function C(q) obtained via (i) the CRAB package, (ii) direct numerical integration of D(ρ), and (iii) fast Fourier transformation (FFT) While numerical integration and FFT are analytically identical and numerically equivalent on an identical momentum grid, FFT reduces the computation time from hours to seconds.
Source Parameter Extraction Details
The analysis extracts the transverse-mass dependence of the L´evy radii, L´evy index α, and correlation strength λ in 0–10 % central collisions The three-dimensional symmetric L´evystable distribution is defined via its inverse Fourier transform as L(α, R2, x) = 1/(2π)3Z d3q e(i q·x) exp-1/2q T R2qa/2. This distribution yields a correlation function C(0)2(qout, qside, qlong) = 1+λ exp - (q 2 outR 2 out + q 2 sideR 2 side + q 2 longR 2 long)/a/2. p. 3 This equation contains five physical parameters to be extracted in each KT interval: the correlation strength λ, the three L´evy radii Rout, Rside, Rlong, and the L´evy index α. p. 3
Methodological Comparison and Consistency
The numerical integration/FFT framework is presented as a significantly faster and more consistent alternative to CRAB because it operates directly on the ensemble-accumulated source and avoids random pair sampling from pooled event classes. The FFT method produces smooth and consistent mT trends with minimal statistical uncertainty, whereas CRAB exhibits pronounced point-to-point fluctuations as a function of the transverse mass mT due to grouping and pair-sampling procedures. p. 8 Both the numerical integration/FFT approach and CRAB are mutually consistent in their correlation functions, with the root-mean-square error (RMSE) between them remaining below 10−14 in every KT bin. p. 9
Systematic Discrepancies
Despite using the exact same simulated dataset, single-particle acceptance, and KT binning, systematic differences appear between momentum-space correlation fits and direct coordinate-space source fits. Specifically, while Rout and λ from the numerical integration/FFT method agree with the direct source fits within ≈ 3 % (with slightly higher λ values at large mT), consistent parameter orderings emerge in Rside (Rsource fit side < RCRAB side ≤ R int/FFT side) and Rlong (RCRAB long < int/FFT long < Rsource fit long). p. 9 Furthermore, momentum-space fits yield L´evy stability indices α that are systematically ∼ 7–9 % lower than those from direct source fits. p. 0
Conclusion on Source Nature
The discrepancies between the direct source fits and the integration/FFT correlation fits may stem both from subtle deviations of the EPOS3 pair source from an ideal three-dimensional L´evy distribution and from comparing event-averaged parameters with fits to an ensemble-accumulated source. The superposition of L´evy distributions with different scales and α values naturally produces a lower effective α when fitted with a single L´evy function. p. 0 Future work will focus on disentangling these effects, including a direct comparison between event-by-event and ensemble-accumulated fits. p. 0
Summary of Findings
The paper concludes that the numerical integration/FFT framework provides a significantly faster and more consistent alternative to CRAB, producing smooth mT dependencies free of grouping- and pair-sampling-induced fluctuations. The FFT shortcut relies on the plane-wave kernel depending solely on q·ρ; when Coulomb or strong final-state interactions are included, the FFT shortcut is lost, whereas direct numerical integration remains applicable at a computational cost of several hours per KT bin. p. 1 The comparison demonstrates that while both momentum-space fits and direct coordinate-space source fits are sensitive to different spatial and momentum regimes, the systematic differences may stem from comparing event-averaged parameters with fits to an ensemble-accumulated source. p. 0
Acknowledgments
This work was supported by NKFIH under grant numbers 2026-4.1.1-MISSZIOK- 2026-00005, PD-146589, and NKKP ADVANCED 152097. p. 0
References
The references listed are:
[M. A. Lisa, S. Pratt, R. Soltz and U. Wiedemann, Ann. Rev. Nucl. Part. Sci., 55, 357 (2005), arXiv:nucl-ex/0505014, doi:10. p. 01146/annurev.nucl.55.090704; T. Cs¨org˝o, Acta Phys. Hung., A 15, 1 (2002), arXiv:hep-ph/0001233; S. p. 0 Pratt, Phys. p. 2 Rev. D 33, 1314 (1986); G. F. Bertsch, Nucl. p. 0 Phys. A 498, 173c (1989); T. Cs¨org˝o, B. L¨orstad and J. Zim´anyi, Z. Phys. C 71, 491 (1996); PHENIX Collaboration (N. J. Abdulameer et al.), Phys. Rev. C 110, 064909 (2024); PHENIX Collaboration (A. Adare et al.), Phys. Rev. C 97, 064911 (2018); CMS Collaboration (A. Tumasyan et al.), Phys. Rev. C 109, 024914; NA61/SHINE Collaboration (H. Adhikary et al.), Eur. Phys. J. C 83, 919; STAR Collaboration (D. Kincses), Universe 10, 102; T. p. 0 Cs¨org˝o, S Hegyi and W A Zajc, Eur. Phys. J. C 36, 67 (2004); M Csan´ad and D Kincses, Universe 10, 54; M Csan´ad, T Cs¨org˝o and M Nagy, Braz. p. 4 J. Phys., 37, 1002; D Kincses, M Stefaniak and M Csan´ad (2026); K Werner et al. p. 0, Phys. Rev. C 82, 044904 (2010); S Pratt et al. p. 2, Nucl. Phys. A 566, 103C (1994); E802 Collaboration (L Ahle et al.), Phys. Rev. C 66, 054906; S E Koonin, Phys. p. 6 Lett. B 70, 43 (1977); S Pratt, T Cs¨org˝o and J Zim´anyi, Phys. p. 2 Rev. C 42, 2646; D Piparo, V Innocente and T Hauth, J. Phys. Conf. Ser., 513, 052027]
Green — the paper says it, and the page is printed. Red — no passage carries it, so treat that sentence as unverified. The same check runs on your own text: check a summary against its source, $5.
Improvements for AI systems
-
Develop an AI system capable of distinguishing between momentum-space correlation methods based on their computational efficiency and fluctuation characteristics. This system can predict that
the numerical integration/FFT framework provides a significantly faster and more consistent alternative to CRAB
while noting thatCRAB results exhibit larger, groupinginduced point-to-point fluctuations.
-
Create an AI system that can systematically quantify the systematic uncertainties associated with different parameter extraction methods. This system should be able to identify that "the discrepancy between the direct source fits and momentum-space fits may stem both from subtle deviations of the EPOS3 pair source from an ideal three-dimensional L´evy distribution and from comparing event-averaged parameters with fits to an ensemble-accumulated source."
-
Implement a system that can automatically select the optimal method for parameter extraction based on desired output characteristics. For instance, if smoothness and minimal statistical uncertainty are prioritized, the system should choose
the numerical integration/FFT approach,
as it producessmooth and consistent mT trends with minimal statistical uncertainty
compared to CRAB'spronounced point-to-point fluctuations.
Sources
- Femtoscopy in Relativistic Heavy Ion Collisions: Two Decades of Progress
- Particle Interferometry from 40 MeV to 40 TeV
- Bose-Einstein Correlations for Systems with Large Halo
- Centrality dependence of L'evy-stable two-pion Bose-Einstein correlations in $\sqrt{s_{_{NN}}}=200$ GeV Au$+$Au collisions
- L'evy-stable two-pion Bose-Einstein correlations in $\sqrt{s_{_{NN}}}=200$ GeV Au$+$Au collisions
- Two-particle Bose-Einstein correlations and their L'evy parameters in PbPb collisions at $\sqrt{s_\mathrm{NN}}$ = 5.02 TeV
- Two-pion femtoscopic correlations in Be+Be collisions at $\sqrt{s_{\textrm{NN}}} = 16.84$ GeV measured by the NA61/SHINE at CERN
- Pion interferometry with L'evy-stable sources in $\sqrt{s_{NN}}$ = 200 GeV Au+Au collisions at STAR
- Bose-Einstein correlations for Levy stable source distributions
- Femtoscopy with L'evy sources from SPS through RHIC to LHC
- Anomalous diffusion of pions at RHIC
- Event-by-event investigation of the two-particle source function in heavy-ion collisions with EPOS
- L'evy walk of pions in heavy-ion collisions
- Event-by-Event Simulation of the Three-Dimensional Hydrodynamic Evolution from Flux Tube Initial Conditions in Ultrarelativistic Heavy Ion Collisions
- Particle species dependence of femtoscopic source parameters in high-energy nuclear collisions
- Three-dimensional sizes and shapes of pion emission in heavy-ion collisions
- System, centrality, and transverse mass dependence of two-pion correlation radii in heavy ion collisions at 11.6 and 14.6 A-GeV
Related papers
- Constrained Hamiltonian Formulation of Kinetic Theory for Relativistic Spin- 1/2 Particles
- Active-subspace learning reveals dominant parameter directions in nuclear observables
- Long- and short-range longitudinal flow decorrelations in the quark-gluon plasma
- Recurrent Fourier Neural Operator for Event-by-Event Relativistic Hydrodynamics
- Bayesian Inference of the Landau Parameter G'0 from Joint Gamow-Teller Measurements
- UrQMD-Agent: An LLM-Assisted Framework for Microscopic Tracing of Proton Azimuthal Correlations