Computational Fluid Dynamics and Discrete Dipole Approximation Applied to Predict Airborne Viruses Disinfection by Ultraviolet Irradiation
physics.flu-dyn, physics.comp-ph
Submitted: 2026-07-07
Updated: 2026-11-02
License: http://creativecommons.org/licenses/by-nc-nd/4.0/
The gist: Ultraviolet (UV) inactivation of airborne viruses involves coupled multiphysics and multiscale processes, yet UV scattering within virus-laden saliva droplets is commonly neglected.
Terminology
Abstract
Ultraviolet (UV) inactivation of airborne viruses involves coupled multiphysics and multiscale processes, yet UV scattering within virus-laden saliva droplets is commonly neglected. Here, for the first time we combine computational fluid dynamics (CFD) and the discrete dipole approximation (DDA) to investigate the influence of droplet-scale UV scattering on airborne virus inactivation. A benchmark CFD-DDA case study is developed and demonstrated that infected saliva droplets can exhibit highly non-uniform UV scattering under representative flow and irradiance conditions. This non-uniformity can substantially affect the predicted number of surviving viral copies, N s, indicating that UV scattering should be considered when modeling UV-based airborne disinfection systems. We systematically investigate the effect on N s by varying: the initially emitted saliva droplets diameter distribution, their number (n(t = 0) = 10 cubed or 10 4), volumetric airflow rate (Q v = 100, 150, or 200 m 3/h), droplet-wall interaction (stick vs escape), and coronavirus UV susceptibility constant (Z = 0.018 or 0.377 m squared /J). The simulations consider initially infected saliva droplets containing 7.4 times 10 8 RNA copies/mL, with a viral capsid diameter of d cap = 100 nm, at an air temperature of 21 °C and relative humidity of 65%. UV irradiation is represented by a 10 W cylindrical UV-lamp (34.3 mW/ cm squared). The DDA results further enable development of an extended virus-inactivation model based on the classical Chick-Watson law that accounts for UV scattering in both spherical and nonspherical infected droplets. The results highlight the importance of resolving local UV-droplet interactions in airborne virus disinfection models and demonstrate the potential of the coupled CFD-DDA approach for improving the design and performance of UV-based airborne disinfection systems.
Related papers
- Emergent Transfer of a Physics Foundation Model from Simulation to Laboratory Turbulence
- Early onset of secondary shear instability in Kelvin-Helmholtz braids at high Reynolds number
- Rotational covariance, continuous spectrum and non-modal growth of three-dimensional planar weak viscous shock layers
- Deep Learning-based Algebraic Reynolds Stress Closures for RANS Simulations of Turbulent Flows
- Neptuna: A Comprehensive Machine Learning Framework for Benchmarking Complex Multiphase Flows
- Size and shape of condensing steam jets and plumes