Demonstration of a Spherical Penning Trap for Single Electrons
Listen
Radio episode about this paper
Transcript
Introduction to the show: ident: Physics. The day in general physics: instruments, methods and results across the field.
Kai: I'm Kai.
Mira: And I'm Mira, here with Lev.
Kai: We're looking at the paper: "Demonstration of a Spherical Penning Trap for Single Electrons".
Mira: Here's the gist of the paper. Single-electron trapping in a spherical Penning trap allows for precise measurement of the electron magnetic moment and enhances sensitivity for dark-photon and axion searches Trap Design and Single-Electron Detection The spherical trap consists of five segmented electrodes with an inner spherical radius of r0 = 3.431 mm The trap is cooled to T = 4.5 K using a pulse-tube refrigerator and a tunable magnetic field of B = 0–6 Tesla is applied Electrons are loaded from a field-emission electron gun made of tungsten The trap geometry is defined by coordinates using the Legendre polynomials Pl(x) as C 0k and Dk.
Kai: The design parameters are set such that the orthogonalized condition (D2 = 0) and the compensated condition (C4 = C6 = 0 at VC /VR = 0.633) are achieved simultaneously.
Mira: Microwave Resonance Characterization The microwave resonances of the spherical trap are characterized using the cyclotron-cooling response of a cloud of electrons The eigenfrequencies for perfect conducting boundaries are given by TE and TM modes.
Kai: For a centered electron, only TMm=±1 n=1 p modes couple to the cyclotron motion in the accessible frequency window.
Title and authors: Kai: So we’re looking at this paper, "Demonstration of a Spherical Penning Trap for Single Electrons," and I mean, the title itself tells you right away that they’re showing how to trap just one electron in a spherical shape. It sounds like a big step forward because traditionally these traps are usually cylindrical or flat.
Mira: Yeah, it sounds attractive, but we need to look at what they actually did in terms of the setup and what that geometry means for the physics we're trying to measure. They’re focusing on using this new spherical trap for measuring both the electron magnetic moment and searching for dark photons or axions.
Lev: I mean, if you can trap a single electron reliably, that’s huge because it lets you probe things at a level that was impossible before in these systems. But how much of the actual hardware complexity are they dealing with when they build this spherical thing?
Kai: Well, looking at the design details on page two of this paper, they used five segmented electrodes and set their geometry using Legendre polynomials to get specific conditions—the orthogonalized and compensated ones—to tune the trap potential. It’s a pretty intricate way to define that sphere.
Mira: And those geometric parameters, theta one equals thirty-eight point eight eight degrees and theta two equals sixty-nine point five six degrees, are chosen specifically to achieve those conditions simultaneously twenty-eight <ref:2606.03639#pg2>. That tuning is key because it lets them control the axial frequency by changing a voltage called V C without messing up the shape too much.
Lev: Controlling that potential tuning sounds like it adds another layer of complexity to the control system. If you have to tune voltages just to get a clean geometry, where does all that overhead land in terms of actual hardware resources?
The paper's summary: Kai: So, what the paper really boils down to is demonstrating this single-electron trapping capability inside this spherical Penning trap and then characterizing the microwave resonance structure. They’re showing they can get a clean signal corresponding to just one electron.
Mira: Exactly, and that characterization part is interesting because they found that for a perfectly conducting spherical trap, there are actually fewer modes than in traditional cylindrical traps when you look at the frequency window between zero and one hundred seventy gigahertz.
Lev: Fewer modes is good for analysis because it means less noise to deal with when trying to measure things like the g-factor or search for new particles. But what does that reduced number of modes actually tell us about the physical system?
Kai: It tells us that this geometry is promising because having fewer modes lets you study each resonant mode in more detail, which is crucial for precision work. They characterized three dominant coupled resonances: one at thirty-eight point three one seven gigahertz, another at eighty-four point seven eight seven gigahertz, and a third at one hundred twenty nine point seven ten gigahertz.
Mira: Those specific frequencies are the output of their cyclotron-cooling response data thirty-one thirty-two <ref:2606.03639#pg3>. So they’re essentially mapping out how this spherical cavity reacts to electron motion in that magnetic field range. It confirms the design parameters they set earlier were working as intended for those modes.
Lev: Mapping out the coupling rate based on sweeping the cyclotron frequency omega c is a solid way to trace that entire coupling behavior, but I wonder what happens if we try to move this setup onto actual hardware with real electron numbers instead of just three hundred electrons.
The paper's improvements: Kai: The paper points out some really concrete improvements they are aiming for in future work. They suggest using this single-electron trapping to directly measure lambda squared M for each individual mode, which is supposed to reduce the systematic error in delta omega c by allowing them to make that measurement at a zero point five percent level.
Mira: That’s a big deal because right now, the biggest systematic error in g-factor measurements comes from this dispersive shift of the cyclotron frequency omega c due to coupling with those cavity resonances twenty-one <ref:2606.03639#pg1>. If they can measure lambda squared M directly for each mode at that low level, it really cuts down on that uncertainty.
Lev: So they are suggesting a strategy where measuring lambda squared M for each mode becomes the new way to handle the systematic error in omega c. That sounds like it shifts the dominant uncertainty somewhere else, which is important for hardware implementation because we have to ensure that measurement itself is high fidelity.
Kai: And they also mention that by doing this, they expect the largest systematic error in determining the g-factor could drop to about two to three times ten to minus fourteen relative precision. That’s a significant reduction compared to what we are seeing now eighteen <ref:2606.03639#pg1>.
Mira: It really shows that this geometry isn't just good for detection; it’s fundamentally better for pushing the precision limits of our Standard Model tests, which is what the g-factor measurement is all about.
Conclusion: Kai: So, to wrap up, the paper on "Demonstration of a Spherical Penning Trap for Single Electrons" shows that this spherical geometry gives us well-separated and clean microwave resonances that are excellent for both measuring the electron magnetic moment and searching for dark photons or axions.
Mira: Right, and they show that because of this shape, the enhancement factor kappa squared is approximately equal to r zero omega c over c squared, which means it’s larger by two to three orders of magnitude compared to traditional cylindrical traps for those searches across a wide frequency range.
Lev: From an engineering standpoint, it sounds like the main advantage here is that you get cleaner data and lower systematic uncertainty if you focus on measuring lambda squared M directly for each mode, which helps bring the g-factor error down to two to three times ten to minus fourteen.
Kai: So, they successfully demonstrated single-electron trapping and characterized the sparse mode structure in this spherical Penning trap. It’s a really promising setup for future precision electron g-factor measurements and dark photon and axion searches with trapped electrons.
Mira: Yeah, it's definitely a path forward because of how the geometry reduces the number of modes we have to worry about when we try to get those high-precision tests of QED.
Lev: I just think it’s a good piece of experimental work showing what’s physically possible with this type of trap structure, even if implementing that level of precision on real hardware is still a massive challenge.
Zirui Fang, *, Xing Fan, ^†
Department of Physics, Harvard University · Harvard-MIT Center for Ultracold Atoms
physics.atom-ph, hep-ex, quant-ph
Submitted: 2026-06-02
Updated: 2026-06-08
Comments: 7 pages, 4 figures
Journal ref: Phys. Rev. A 114, 052805 (2026)
DOI: 10.1103/n3xf-344l
License: http://arxiv.org/licenses/nonexclusive-distrib/1.0/
Importance score: 91/100
The gist: Single-electron trapping in a spherical Penning trap allows for precise measurement of the electron magnetic moment and enhances sensitivity for dark-photon and axion searches Trap Design and…
Key concepts
- Penning Trap
- A device used to trap single charged particles like electrons using a combination of strong magnetic fields and oscillating electric fields. This setup allows scientists to study the quantum motion of a single electron with high precision, which is essential for measuring fundamental constants.
- g-factor
- The g-factor is a fundamental property that describes how an electron's spin interacts with an external magnetic field. Measuring it precisely tests the predictions of Quantum Electrodynamics (QED), providing a stringent test of the Standard Model.
- Cavity-QED Systematic Effect
- This is a major error in g-factor measurements caused by the interaction between the electron's motion and the electromagnetic resonances within the trap's cavity. The spherical design aims to reduce this error by engineering geometry to keep these coupling effects weak.
- Dark Photon/Axion Search Enhancement
- The spherical shape focuses perpendicularly emitted photons toward the trap center, significantly boosting detection efficiency for dark photons and axions compared to traditional cylindrical traps. This focus provides an enhancement factor of two to three orders of magnitude over a wide frequency range.
Terminology
Summary
Single-electron trapping in a spherical Penning trap allows for precise measurement of the electron magnetic moment and enhances sensitivity for dark-photon and axion searches
Trap Design and Single-Electron Detection
The spherical trap consists of five segmented electrodes with an inner spherical radius of r0 = 3.431 mm The trap is cooled to T = 4. p. 05 K using a pulse-tube refrigerator and a tunable magnetic field of B = 0–6 Tesla is applied Electrons are loaded from a field-emission electron gun made of tungsten The trap geometry is defined by coordinates using the Legendre polynomials Pl(x) as C 0k and Dk. p. 0 The design parameters are set such that the orthogonalized condition (D2 = 0) and the compensated condition (C4 = C6 = 0 at VC /VR = 0. p. 1633) are achieved simultaneously. p. 1
Microwave Resonance Characterization
The microwave resonances of the spherical trap are characterized using the cyclotron-cooling response of a cloud of electrons The eigenfrequencies for perfect conducting boundaries are given by TE and TM modes. For a centered electron, only TMm=±1 n=1 p modes couple to the cyclotron motion in the accessible frequency window. p. 2 The three dominant coupled resonances are fTM±111 = 38. p. 3317(27) GHz, fTM±11 2 = 84. p. 2787(60) GHz, and fTM±11 3 = 129. p. 2710(91) GHz. p. 2 The fitted cold-cavity radius is r0 = 3. p. 2431(6) mm.
G-Factor Measurement and Systematic Error Reduction
The spherical trap offers a new strategy for measuring the g-factor by allowing direct measurement of the coupling constant λ 2M for each individual mode. This approach aims to reduce the systematic error in δωc, which is currently dominated by the uncertainty of λ 2M. p. 5 The g-factor's systematic error could be reduced to δg/g ≃ 2–3 × 10−14 with this strategy.
Dark-Photon and Axion Searches Enhancement
The spherical trap enhances sensitivity for dark photons and axions by focusing perpendicularly emitted photons at the center of the trap. This results in an enhancement factor κ 2 approximately κ 2 ≃ (r0ωc/c)2. p. 5 Over a wide frequency range, κ 2 is larger by 2–3 orders of magnitude in the spherical trap compared to traditional cylindrical traps. p. 5
Conclusion
The paper successfully demonstrates single-electron trapping and detection in a spherical Penning trap and characterizes its microwave resonances showing a sparse mode structure. The reduced number of modes suggests this geometry is promising for future precision electron g-factor measurements and dark-photon and axion searches. p. 5
ACKNOWLEDGMENTS
This work is supported by the National Science Foundation Award No. 2317134 X.F. acknowledges support from the Masason Foundation
DATA AVAILABILITY
The data that support the findings of this article are available from the corresponding author upon reasonable request
REFERENCES
[1] X. Fan, T. G. Myers, B. A. D. Sukra, and G. p. 5 Gabrielse, “Measurement of the electron magnetic moment,” Phys. p. 5 Rev. Lett. 130, 071801 (2023). p. 5
[2] D. Hanneke, S. p. 5 p. 5 Fogwell, and G. p. 5 Gabrielse, “New measurement of the electron magnetic moment and the fine structure constant,” Phys. p. 5 Rev. Lett. 100, 120801 (2008). p. 5
[3] B. Odom, D. Hanneke, B. p. 5 D’Urso, and G. p. 5 Gabrielse, “New measurement of the electron magnetic moment using a one-electron quantum cyclotron,” Phys. p. 5 Rev. Lett. 97, 030801 (2006). p. 5
[4] Robert S. p. 5 Van Dyck, Paul B. p. 5 Schwinberg, and Hans G. p. 5 Dehmelt, “New high-precision comparison of electro and positron g factors,” Phys. p. 5 Rev. Lett. 59, 26–29 (1987). p. 6
[5] Xing Fan, Gerald Gabrielse, Peter W. p. 6 Graham, Harikrishnan Ramani, Samuel S. p. 6 Y. Wong, and Yawen Xiao, “Highly excited electron cyclotron for QCD axion and dark-photon detection,” Phys. p. 6 Rev. D 111, 075022 (2025). p. 6
[6] Xing Fan, Gerald Gabrielse, Peter W. p. 6 Graham, Roni Harnik, Thomas G. p. 6 Myers, Harikrishnan Ramani, Benedict A. p. 6 D. Sukra, Samuel S. p. 6 Y. Wong, and Yawen Xiao, “One-electron quantum cyclotron as a milli-eV darkphoton detector,” Phys. p. 6 Rev. Lett. 129, 261801 (2022). p. 6
[7] Jack A. p. 6 Devlin, Marko L. p. 6 Wojtkowiak, Shreyak R. p. 6 Banhatti, He Zhang, Jiacheng Shi, Toren S. p. 6 Dofher, Jonathan M. p. 6 H. Gosling, Michael R. p. 6 Tarbutt, and Richard C. p. 6 Thompson, “A Penning trap single-photon counter for axion detection,” (2026), arXiv:2601. p. 605472 [hep-ph]. p. 6
[8] Stefano Laporta, “High-precision calculation of the 4-loop contribution to the electron g − 2 in QED,” Physics Letters B 772, 232 – 238 (1987). p. 6
[9] Tatsumi Aoyama, Masashi Hayakawa, Toichiro Kinoshita, and Makiko Nio, “Tenth-order electron anomalous magnetic moment: Contribution of diagrams without closed lepton loops,” Phys. p. 6 Rev. D 91, 033006 (2015). p. 6
[10] Tatsumi Aoyama, Toichiro Kinoshita, and Makiko Nio, “Revised and improved value of the QED tenth-order electron anomalous magnetic moment,” Phys. p. 6 Rev. D 97, 036001 (2018). p. 6
[11] Tatsumi Aoyama, Toichiro Kinoshita, and Makiko Nio, “Theory of the anomalous magnetic moment of the electron,” Atoms 7 (2019), 10. p. 63390/atoms7010028. p. 6
[12] Sergey Volkov, “Numerical calculation of high-order QED contributions to the electron anomalous magnetic moment,” Phys. p. 6 Rev. D 98, 076018 (2018). p. 6
[13] Sergey Volkov, “New method of computing the contributions of graphs without lepton loops to the electron anomalous magnetic moment in QED,” Phys. p. 6 Rev. D 96, 096018 (2017). p. 6
[14] Sergey Volkov, “Calculating the five-loop QED contribution to the electron anomalous magnetic moment: Graphs without lepton loops,” Phys. p. 6 Rev. D 100, 096004 (2019). p. 6
[15] Sergey Volkov, “Calculation of lepton magnetic moments in quantum electrodynamics: A justification of the flexible divergence elimination method,” Phys. p. 6 Rev. D 109, 036012 (2024). p. 6
[16] Ryuichiro Kitano, “QED five-loop on the lattice,” Progress of Theoretical and Experimental Physics 2025, 013B02 (2025). p. 6
[17] G. Gabrielse, S. p. 5 E. Fayer, T. G. Myers, and X. p. 6 Fan, “Towards an improved test of the Standard Model’s most precise prediction,” Atoms 7, 45 (2019). p. 6
[18] G. Gabrielse, D. p. 5 Hanneke, T. p. 5 Kinoshita, M. p. 6 Nio, and B. p. 6 Odom, “New determination of the fine-structure constant from the electron g value and QED,” Phys. p. 6 Rev. Lett. 97, 030802 (2006). p. 6
[19] L´eo Morel, Zhibin Yao, Pierre Clad´e, and Sa¨ıda GuellatiKh´elifa, “Determination of the fine-structure constant with an accuracy of 81 parts per trillion,” Nature (London) 588, 61–65 (2020). p. 6
[20] Richard H. p. 6 Parker, Chenghui Yu, Weicheng Zhong, Brian Estey, and Holger M¨uller, “Measurement of the finestructure constant as a test of the Standard Model,” Science 360, 191–195 (2018). p. 6
[21] Lowell S. p. 6 Brown, Gerald Gabrielse, Kristian Helmerson, and Joseph Tan, “Cyclotron motion in a microwave cavity: Lifetime and frequency shifts,” Phys. p. 6 Rev. A 32, 3204–3218 (1985). p. 6
[22] Lowell S. p. 6 Brown, Gerald Gabrielse, Kristian Helmerson, and Joseph Tan, “Cyclotron motion in a microwave cavity: Possible shifts of the measured electron g factor,” Phys. p. 6 Rev. Lett. 55, 44–47 (1985). p. 6
[23] D. Hanneke, S. Fogwell Hoogerheide, and G. p. 6 Gabrielse, “Cavity control of a single-electron quantum cyclotron: Measuring the electron magnetic moment,” Phys. p. 6 Rev. A 83, 052122 (2011). p. 6
[24] Xing Fan, An improved measurement of the electron magnetic moment, Ph. p. 6D. thesis, Harvard University (2022). p. 6
[25] Dieter Horns, Joerg Jaeckel, Axel Lindner, Andrei Lobanov, Javier Redondo, and Andreas Ringwald, “Searching for WISPy cold dark matter with a dish antenna,” Journal of Cosmology and Astroparticle Physics 2013, 016–016 (2013). p. 6
[26] Gerald Gabrielse and F. p. 6Colin Mackintosh, “Cylindrical Penning traps with orthogonalized anharmonicity compensation,” International Journal of Mass Spectrometry and Ion Processes 57, 1–17 (1984). p. 6
[27] Joseph Tan and Gerald Gabrielse, “One electron in an orthogonalized cylindrical Penning trap,” Applied Physics Letters 55, 2144–2146 (1989). p. 6
[28] Lowell S. p. 6 Brown, Kristian Helmerson, and Joseph Tan, “Cyclotron motion in a spherical microwave cavity,” Phys. p. 6 Rev. A 34, 2638–2645 (1986). p. 6
[29] David A. p. 6 Hill, Electromagnetic fields in cavities: Deterministic and statistical theories (Wiley, 2009). p. 6
[30] D. J. Wineland and H. p. 6 G. Dehmelt, “Principles of the stored ion calorimeter,” Journal of Applied Physics 46, 919–930 (1975). p. 6
[31] J. Tan and G. Gabrielse, “Parametrically pumped electron oscillators,” Phys. p. 6 Rev. A 48, 3105–3122 (1993). p. 6
[32] J. Tan and G. Gabrielse, “Synchronization of parametrically pumped electron oscillators with phase bistability,” Phys. p. 6 Rev. Lett. 67, 3090–3093 (1991). p. 6
[34] Jr. Van Dyck, R. p. 5 S., D. L. Farnham, S. p. 6 L. Zafonte, and P. p. 6 B. Schwinberg, “Ultrastable superconducting magnet system for a Penning trap mass spectrometer,” Review of Scientific Instruments 70, 1665–1671 (1999). p. 6
[35] X. Fan, S. E. Fayer, and G. p. 6 Gabrielse, “Gaseous 3He nuclear magnetic resonance probe for cryogenic environments,” Review of Scientific Instruments 90, 083107 (2019). p. 6
[36] Lowell S. p. 6 Brown and Gerald Gabrielse, “Geonium theory: Physics of a single electron or ion in a Penning trap,” Rev. p. 6 Mod. Phys. 58, 233–311 (1986). p. 6
[37] B. D’Urso, R. p. 5 Van Handel, B. p. 6 Odom, D. Hanneke, and G. p. 5 Gabrielse, “Single-particle self-excited oscillator,” Phys. p. 6 Rev. Lett. 94, 113002 (2005). p. 6
[38] Xing Fan, Atsushi Noguchi, and Kento Taniguchi, “Quantum-logic spectroscopy of an electron or positron for precise tests of the Standard Model,” Phys. p. 6 Rev. A 111, 042806 (2025). p. 6
--- Page 1 ---
Demonstration of a spherical Penning trap for single electrons Zirui Fang and Xing Fan Department of Physics, Harvard University, Cambridge, Massachusetts 02138, USA Harvard-MIT Center for Ultracold Atoms, Cambridge, MA 02138 (Dated: June 10, 2026) A spherical Penning trap has well-separated, clean microwave resonances, making it attractive for precision measurements of the electron magnetic moment and for dark-photon and axion searches with trapped electrons We demonstrate single-electron trapping in a spherical Penning trap and characterize its microwave resonance structure
I. INTRODUCTION
Single electrons in Penning traps provide an ideal system for the precise measurement of the electron’s magnetic moment (g-factor)[1–4] and for dark-photon and axion searches[5–7] Precision measurement of the g-factor provides the most precise test of the quantum electrodynamics (QED) calculations[8–17] and determination of the fine-structure constant[18–20] To determine the g-factor, g = 2ωs/ωc, the ratio of the spin frequency ωs to the cyclotron frequency ωc is measured at better than 10−12 relative precision In this measurement, one of the largest systematic errors is the dispersive shift of ωc from the coupling of the electron to the Penning trap’s microwave resonances This is the so-called cavity-QED systematic effect, shifting the measured gfactor as δg/g ≃ −δωc/ωc A typical Penning trap’s size is about d = 3–5 mm and its interior is made of conductors, creating several cavity resonances near the electron’s cyclotron frequency ωc ∼ 2π × 100 GHz
Cavity-QED Systematic Effects
The dispersive shift of ωc from the coupling of the electron to the Penning trap’s microwave resonances is a major systematic error in g-factor measurements. This effect scales as δωc ∝ d −3 (ω 2c − ω 2M)−1 [21]. p. 0 Making the trap smaller to increase the mode separation does not solve this problem, as the coupling instead becomes stronger for smaller d. p. 0 The shift does not depend on the Q-factor of the resonant modes, so one must engineer geometry to keep resonances far away and coupling weak. p. 0
Spherical Trap Advantages for Searches
In a spherical trap, perpendicularly emitted photons are focused at the center of the trap, collectively enhancing detection efficiency compared to traditional cylindrical traps. This enhancement can be 1–2 orders of magnitude compared to cylindrical traps. p. 0 The spherical geometry leads to fewer modes than in traditional cylindrical Penning traps, allowing for a detailed study of each resonant mode. p. 0
Microwave Mode Structure
For a spherical trap with the same inner volume as the 2023 cylindrical trap, there are only 3 modes that couple to a centered electron to leading order from 0 to 170 GHz, compared to 28 modes for the cylindrical trap. This reduced number of modes allows for a detailed study of each resonant mode for the electron’s g-factor measurement. p. 0
The spherical Penning trap is attractive due to its well-separated, clean microwave resonances and enhanced sensitivity for dark-photon and axion searches.
--- Page 2 ---
Figure 1 shows the geometry of the spherical trap as well as the definition of coordinates The trap consists of five segmented electrodes with an inner spherical radius of r0 = 3.431 mm The whole trap is cooled to T = 4. p. 05 K using a pulse-tube refrigerator and a tunable magnetic field of B = 0–6 Tesla is applied A helical inductor with l = 200 nH, made of oxygenfree high-conductivity copper, is attached to the top endcap and compensation electrodes The parasitic capacitance c = 20 pF forms a resonator at an axial frequency ωz/(2π) = 76. p. 18 MHz with a quality factor Q = 920. p. 1
Trap Geometry Details
The trap geometry is defined by the equations for the potential along the z-axis using Legendre polynomials. The design parameters θ1 = 38. p. 188◦ and θ2 = 69. p. 156◦ are chosen to achieve the orthogonalized condition (D2 = 0) and the compensated condition (C4 = C6 = 0 at VC /VR = 0. p. 1633). The axial frequency is given by ωz = p 2C2eVR/(mer 2 0). p. 1
Single-Electron Detection
The detection capability is demonstrated by monitoring the oscillation amplitude with a parametric drive while firing the electron gun. The direct measurement of γ = N γz is achieved by exciting to a large amplitude and monitoring its decay. p. 1 The Fourier transform of the output signal shows a dip corresponding to a single electron, demonstrating detection capability. p. 1
Green — the paper says it, and the page is printed. Red — no passage carries it, so treat that sentence as unverified. The same check runs on your own text: check a summary against its source, $5.
Improvements for AI systems
-
Precise g-factor measurement capability: The spherical trap geometry allows for direct measurement of lambda squared M for each individual mode, which is expected to reduce systematic error in delta omega c by allowing a direct measurement of lambda squared M at the 0.5% level.
-
Dark-photon and axion search enhancement: The spherical trap provides an enhancement factor kappa squared approximately equal to kappa squared approximately (r0 omega c over c) squared, which is larger by 2 to 3 orders of magnitude over a wide frequency range compared to cylindrical traps for these searches.
-
Systematic error reduction in g-factor determination: By directly measuring lambda squared M for each mode, the largest systematic error with this strategy will then become the uncertainty of omega M’s center frequency, and the g-factor’s systematic error could be reduced to delta g over g equal to 2 to 3 times 10 to minus 14.
Sources
Related papers
- Precision Isotope-Shift Measurement of the 1S 0 3P 2 Transition and a Multi-Transition King-Plot Consistency Test
- White-Light Matter-Wave Interferometry
- Testing Exotic Electron-Electron Interactions with the Helium Ionization-Energy Anomaly
- In-Situ Differential-Light-Shift Cancellation for Trapped-Atom Clocks
- Local polarization control of optical tweezer arrays
- A nuclear clock synchronized to 229 Th