Performance study of the JadePix-3 telescope from a beam test

arXiv:2401.06530 · hep-ex · Submitted 2024-01-12 · Read on arXiv

Listen

Radio episode about this paper

Transcript

Introduction to the show: ident: High Energy Physics: Experiment. The day in high-energy experiment: detectors, searches and limits.

Kai: We're looking at the paper: "Performance study of the JadePix-3 telescope from a beam test".

Mira: Here's the gist of the paper. Performance study of the JadePix-3 telescope from a beam test presents results from a beam test conducted on a telescope using the JadePix-3 pixel sensor, developed with TowerJazz 180 nm CMOS imaging technology At an electron energy of 5.4 GeV, the telescope demonstrated superior spatial resolutions of 2.6 and 2.3 µm in two dimensions By designating the central plane as the device under test, we evaluated the JadePix-3 sensor’s spatial resolutions as 5.2 and 4.6 µm in two dimensions, achieving a detection efficiency of over 99.0 % Telescope Implementation The telescope is composed of five planes, labeled P0, P1, P2, P3, and P4, with P2 serving as the device under test (DUT) The distance between the planes is fixed to 26 mm Each telescope plane includes a commercial FPGA evaluation board (KC705), a sensor bonding board, and an FMC adaptor facilitating communication between the sensor and the FPGA The global coordinate system is established as a right-handed Cartesian system, with the positive z-axis aligned with the beam direction, and the origin defined within the plane P2 Data Acquisition and Synchronization A data acquisition (DAQ) system, using the IPbus framework, was developed This scalability was a key factor in selecting IPbus, as it facilitated the seamless expansion to a multi-chip readout system A software command using the IPbus protocol is sent to the primary plane P0, and a synchronous start command (SYNC) signal is transmitted via a daisy-chain link to the next secondary plane sequentially This approach guarantees that all planes start operations in a synchronized way Spatial Resolution Analysis The unbiased residual distributions in the x and y directions are illustrated in Figure 10, where the red/blue line represents the Gaussian fit of the data The σ of the position residual distribution for the DUT in the x and y directions are 6.7 and 5.2 µm, respectively The scaling factor k for the JadePix-3 telescope has been calculated as 0.25 Consequently, the spatial resolution for the DUT is determined to be 6.0 and 4.7 µm in the x and y directions, respectively Optimal Operational Threshold Based on the threshold scan conducted within this range, setting the JadePix-3 threshold around 200 a is recommended This setting not only improves spatial resolution and detection efficiency, but also maintains a low fake-hit rate even at reduced thresholds This study presents the development, testing, and comprehensive analysis of a beam telescope equipped with the JadePix-3 CMOS pixel sensor At an electron energy of 5.4 GeV, the telescope demonstrated excellent spatial resolutions of 2.6 and 2.3 µm in two dimensions The study also included a comprehensive investigation of various CSs, focusing on the spatial resolution of the JadePix-3 sensor in the DUT plane Through the analysis of a series of threshold scanning results, we determined the optimal operational threshold for the sensor Acknowledgments This study was supported by the National Key Research and Development Program of China (Grant No.

Kai: 2016YFA0400400), the Strategic Priority Research Program of the Chinese Academy of Sciences (Grant No.

Mira: XPB23), and the Fundamental Research Funds for the Central Universities of China (WK2360000014) <ref:2451.

Title and authors: Kai: So we're looking at this paper now: "Performance study of the JadePix-three telescope from a beam test <ref:2401.06530#pg1,Performance study of the JadePix-3 telescope from a beam test>." It’s about testing a new pixel sensor in a real setup, and it’s interesting because it shows how this technology performs when you actually put it into a telescope >

Mira: Yeah, the authors are Sheng Donga and his team, and they use this JadePix-three sensor developed with TowerJazz one hundred eighty nm CMOS imaging technology <ref:2401.06530#pg1,sensor developed with TowerJazz 180 nm CMOS imaging technology>. I'm curious what kind of results they actually got from this beam test >

Mira: And it's important to remember that they are emphasizing high spatial resolution and low power consumption with this JadePix-three sensor, which is a prototype for a vertex detector at the Circular Electron Positron Collider > <ref:2401.06530#pg1>

The paper's summary: Kai: The summary of "Performance study of the JadePix-three telescope from a beam test" shows that when they fired an electron beam at five point four gigaelectron volt, this telescope demonstrated spatial resolutions of two point six and two point three micrometers in two dimensions > <ref:2401.06530#pg2>

Mira: That's actually quite good, especially when you consider the demands for a vertex detector where the requirement is better than three micrometers for single-point resolution >

Lev: But they also focus on evaluating the JadePix-three sensor specifically in Plane Two, which is the DUT, and they found its spatial resolutions there to be five point two and four point six micrometers in two dimensions >

Kai: So there's a difference between how the whole telescope performs and how this specific sensor works when you isolate it, which is something we need to keep in mind >

Mira: Exactly. And they also mention achieving a detection efficiency of over ninety-nine point zero percent for this test run >

The paper's improvements: Kai: Now, the authors suggest some ways to improve the system. One big idea is using General Broken Lines, or GBL, as the primary algorithm for track reconstruction instead of just straight-line methods >

Mira: That makes sense because when you’re dealing with cluster data from a pixel sensor, those straight lines aren't always the most accurate way to reconstruct the actual particle tracks >

Lev: For real hardware, implementing GBL would definitely increase computational overhead compared to simpler reconstruction methods, so we need to see how that scales on our actual processing units >

Kai: They also suggest an AI system for precise alignment by evaluating the chi-square per degree of freedom and looking at the distance distribution between tracks and hits >

Mira: That kind of spatial analysis using AI could help nail down the alignment much more reliably than just relying on geometric fits alone, which is a key assumption there >

Lev: If we talk about running this on real hardware, that kind of iterative alignment process would add significant latency to the data readout pipeline, so the overhead really lands there >

Conclusion: Kai: So to wrap up this paper "Performance study of the JadePix-three telescope from a beam test," they confirm that setting the JadePix-three threshold around two hundred alpha is recommended for optimal performance > <ref:2401.06530#pg1,Performance study of the JadePix-3 telescope from a beam test>

Mira: They say this specific threshold isn't just about getting better spatial resolution, but it also helps maintain a low fake hit rate even when you are reducing the thresholds >

Lev: From an engineering standpoint, achieving that detection efficiency and keeping the fake hit rate low with that threshold setting is what we need to focus on for any practical deployment >

Kai: Ultimately, this study shows how the JadePix-three sensor performs in a real beam test setup at five point four gigaelectron volt, giving us those two dimensional resolutions of two point six and two point three micrometers > <ref:2401.06530#pg1>

Mira: It’s a solid piece of work showing the capabilities of this CMOS technology for vertex detection applications >

Lev: It gives us concrete numbers on what we can expect from the sensor itself, even if we have to account for the processing overhead they mentioned in their method section when building something real >

State Key Laboratory of Particle Detection and Electronics, Institute of High Energy Physics, Chinese Academy of Sciences · State Key Laboratory of Particle Detection and Electronics, University of Science and Technology of China · Department of Modern Physics, University of Science and Technology of China · University of Chinese Academy Sciences

hep-ex

Submitted: 2024-01-12

Updated: 2024-05-27

DOI: 10.1016/j.nima.2024.169551

License: http://arxiv.org/licenses/nonexclusive-distrib/1.0/

Importance score: 79/100

The gist: Performance study of the JadePix-3 telescope from a beam test presents results from a beam test conducted on a telescope using the JadePix-3 pixel sensor…

Key concepts

JadePix-3 Sensor
This is a specific pixel sensor developed using TowerJazz 180 nm CMOS imaging technology. It is the core component used in the telescope to detect particles and measure their positions with high precision during a beam test.
Spatial Resolution
This measures how well the telescope can distinguish between two closely spaced points. The study found that for the JadePix-3 sensor, this resolution was 5.2 and 4.6 µm in the x and y directions when testing its central plane.
Operational Threshold
This is a setting applied to the JadePix-3 sensor to decide which signals are counted as actual particle hits. The study recommends setting this threshold around 200 a to balance good spatial resolution, high detection efficiency, and a low rate of false detections.

Terminology

Summary

Performance study of the JadePix-3 telescope from a beam test presents results from a beam test conducted on a telescope using the JadePix-3 pixel sensor, developed with TowerJazz 180 nm CMOS imaging technology At an electron energy of 5. p. 04 GeV, the telescope demonstrated superior spatial resolutions of 2. p. 06 and 2.3 µm in two dimensions By designating the central plane as the device under test, we evaluated the JadePix-3 sensor’s spatial resolutions as 5. p. 02 and 4.6 µm in two dimensions, achieving a detection efficiency of over 99. p. 00 %

Telescope Implementation

The telescope is composed of five planes, labeled P0, P1, P2, P3, and P4, with P2 serving as the device under test (DUT) The distance between the planes is fixed to 26 mm Each telescope plane includes a commercial FPGA evaluation board (KC705), a sensor bonding board, and an FMC adaptor facilitating communication between the sensor and the FPGA The global coordinate system is established as a right-handed Cartesian system, with the positive z-axis aligned with the beam direction, and the origin defined within the plane P2

Data Acquisition and Synchronization

A data acquisition (DAQ) system, using the IPbus framework, was developed This scalability was a key factor in selecting IPbus, as it facilitated the seamless expansion to a multi-chip readout system A software command using the IPbus protocol is sent to the primary plane P0, and a synchronous start command (SYNC) signal is transmitted via a daisy-chain link to the next secondary plane sequentially This approach guarantees that all planes start operations in a synchronized way

Spatial Resolution Analysis

The unbiased residual distributions in the x and y directions are illustrated in Figure 10, where the red/blue line represents the Gaussian fit of the data The σ of the position residual distribution for the DUT in the x and y directions are 6.7 and 5.2 µm, respectively The scaling factor k for the JadePix-3 telescope has been calculated as 0. p. 325 Consequently, the spatial resolution for the DUT is determined to be 6. p. 60 and 4.7 µm in the x and y directions, respectively

Optimal Operational Threshold

Based on the threshold scan conducted within this range, setting the JadePix-3 threshold around 200 a is recommended This setting not only improves spatial resolution and detection efficiency, but also maintains a low fake-hit rate even at reduced thresholds

Conclusion

This study presents the development, testing, and comprehensive analysis of a beam telescope equipped with the JadePix-3 CMOS pixel sensor At an electron energy of 5.4 GeV, the telescope demonstrated excellent spatial resolutions of 2. p. 06 and 2.3 µm in two dimensions The study also included a comprehensive investigation of various CSs, focusing on the spatial resolution of the JadePix-3 sensor in the DUT plane Through the analysis of a series of threshold scanning results, we determined the optimal operational threshold for the sensor

Acknowledgments

This study was supported by the National Key Research and Development Program of China (Grant No. 2016YFA0400400), the Strategic Priority Research Program of the Chinese Academy of Sciences (Grant No. p. 0 XPB23), and the Fundamental Research Funds for the Central Universities of China (WK2360000014) <ref:2451. p. 0

Green — the paper says it, and the page is printed. Red — no passage carries it, so treat that sentence as unverified. The same check runs on your own text: check a summary against its source, $5.

Improvements for AI systems

  1. Improved track reconstruction using General Broken Lines (GBL) as the primary algorithm provides more accurate analytical results compared to straight-line methods for reconstructing particle tracks from cluster data.

  2. The AI system can perform precise alignment by evaluating the chi-square per degree of freedom and the distance distribution between tracks and hits, ensuring precise and reliable tracking performance.

  3. The system can determine the spatial resolution of the DUT plane by calculating Equation 4, which states that sigma squared DUT = sigma squared plane = sigma squared meas / (1 + k).

  4. The AI system can optimize the operational threshold for the JadePix-3 sensor by analyzing threshold scan results to attain the most favorable spatial resolution and efficiency under these specific threshold conditions.

  5. The improved system can achieve high detection efficiency and a low fake hit rate by setting the JadePix-3 threshold around 200 a, as recommended by the authors.

Sources