ANUBIS detector and its sensitivity to neutral long-lived particles

summary

The gist

Long-lived particles (LLPs), i.e., particles with macroscopic lifetimes τ > 10 ps, appear in various extensions of the Standard Model (SM) that address fundamental questions like the particulate…

In short

ANUBIS is a proposed detector at the High-Luminosity LHC designed to find long-lived particles (LLPs), which are predicted by some extensions of the Standard Model. The project compares two layouts—a 'shaft' and a 'ceiling' configuration—to maximize sensitivity. Simulations suggest the ceiling configuration offers superior sensitivity, potentially probing Higgs decays into these particles with branching ratios down to $10^{-6}$.

Key concepts

Long-Lived Particles (LLPs)
These are hypothetical particles with very long lifetimes, lasting longer than 10 nanoseconds. They appear in theories beyond the Standard Model and could be related to dark matter or baryogenesis. ANUBIS is designed to detect them by looking for specific decay signatures.
Displaced Vertex (DV)
This is the key signature ANUBIS looks for: a point where charged particle tracks start, but this point is some distance away from the main collision spot. This displacement indicates that the parent particle decayed into an LLP that traveled a measurable distance before decaying.
Ceiling Configuration
One of two proposed detector layouts. This setup places tracking layers directly onto the cavern ceiling, separated by 1 meter. It is favored because it offers a larger solid angle coverage, allowing it to capture LLP decays occurring further away from the main interaction point compared to the 'shaft' configuration.
Higgs Decay Benchmark
The analysis focuses on the Higgs boson decaying into a pair of neutral scalar LLPs ($h ightarrow ss$). This specific decay channel is chosen because it is common in various Beyond Standard Model (BSM) scenarios, making it a primary target for testing new physics models.

Terminology used across episodes

This episode discusses

The paper

ANUBIS detector and its sensitivity to neutral long-lived particles · Read on arXiv

Thomas Adolphus, Giulio Aielli, Jahanzeb Akhtar, Arun Atwal, Martin Bauer, Rachel Bentham, Oleg Brandt, Jude Burling, Jon Burr, È Patrick Collins” Louie Dartmoor Corpe Matthew Coxon Jonas Dej Sofie Nordahl Erner Cayetano Fernandez Ruiz Jindrich Jelinek Oliver Kortner Hubert Kroha Lawrence Lee Jr Christopher Lester Yingshan Liang Kaijia Liu Anna Mullin Christian Ohm David Peng Luca Pizzimento Ludovico Pontecorvo Giorgia Proto Théeo Reymermier Michael Revering Elisa Ritz Thomas P. Satterthwaite Aashaq Shah Sinem Simsek Daniel Soyk Tom Spencer Paul Swallow Balint Szepfalvi Noshin Tarannum Olivia Valentino Julian Wack Yanglin Wan Peng Wang Esperanza Winter Lopez Monami Yoshioka Yingchang Zhang, orgs_list_extracted_and_expanded

Cavendish Laboratory, University of Cambridge · University and INFN Roma Tor Vergata · School of Sciences and Engineering, Glasgow Caledonian University · IPPP, Department of Physics, Durham University · Department of Physics and Astronomy, University of Manchester · Cavendish Laboratory, University of Cambridge · Université Clermont Auvergne / Laboratoire de Physique de Clermont Auvergne, CNRS/IN2P3 · Max Planck Institute for Physics, Munich · Department of Physics, University of Tennessee Knoxville · KTH Royal Institute of Technology Stockholm · Department of Physics, University of Hong Kong SAR · CERN, Geneva

Long-lived particles (LLPs), i.e., particles with macroscopic lifetimes τ>10 ns, appear in various extensions of the Standard Model (SM) that address fundamental questions like the particulate nature of dark matter or baryogenesis. The ANUBIS detector will achieve unprecedented sensitivity to such models compared to existing and approved experiments by instrumenting a large decay volume adjacent to the ATLAS experiment at the High-Luminosity LHC with tracking detectors. This paper outlines the proposed detector layouts for ANUBIS, explores their physics potential with a scalar LLP model, and identifies the preferred layout, comparing it to other experiments. The potential background contributions to ANUBIS are estimated using a data-driven method, and the topology of potential background events is studied using Monte Carlo simulations. Overall, ANUBIS is expected to probe branching ratios down to O (10-6) for exotic decays of the Higgs boson to scalar long-lived particles with masses of 10, 15, 40, and 60 GeV and proper lifetimes of cτ=2.4,, 3.0,, 12, and 18 m, respectively. Moreover, for branching ratios of 0.1% of the Higgs boson into long-lived scalars with a mass of 15 GeV, ANUBIS can probe a cτ range between 1.1 times10-1 m and 4.0 times10 cubed m.

DOI: 10.1103/kd5j-d4fv

Transcript

Introduction to the show: ident: High Energy Physics: Experiment. The day in high-energy experiment: detectors, searches and limits.

Kai: We're looking at the paper: "ANUBIS detector and its sensitivity to neutral long-lived particles".

Mira: Here's the gist of the paper. Long-lived particles (LLPs), i.e., particles with macroscopic lifetimes τ > 10 ps, appear in various extensions of the Standard Model (SM) that address fundamental questions like the particulate nature of dark matter or baryogenesis The ANUBIS detector will achieve unprecedented sensitivity to such models compared to existing and approved experiments by instrumenting a large decay volume adjacent to the ATLAS experiment at the High-Luminosity LHC with tracking detectors This paper outlines the proposed detector layouts for ANUBIS, explores their physics potential with a scalar LLP model, and identifies the preferred layout, comparing it to other experiments Overall, the ANUBIS detector is expected to probe branching ratios down to O(10−6) for exotic decays of the Higgs boson to scalar long-lived particles with masses of 10, 15, 40, and 60 GeV and proper lifetimes of cτ = 2.4, 3.0, 12, and 18 m, respectively Moreover, for branching ratios of 0.1% of the Higgs boson into long-lived scalars with a mass of 15 GeV, the ANUBIS detector can probe a cτ range between 1.1 × 10−1 m and 4.0 × 103 m.

Kai: Detector Layouts and Physics Potential The ANUBIS detector exploits the ‘smoking gun’ signature of neutral LLP decays: an isolated displaced vertex (DV) of charged particle tracks emanating from the decay position of the LLP some distance away from the interaction point It will utilise Resistive Plate Chambers (RPCs) as the tracking technology Two detector configurations of the ANUBIS project, as depicted in Figure 2, are evaluated through simulation studies The ‘shaft configuration’ was the first studied and involves suspending four tracking stations within the ATLAS PX14 service shaft, at distances ranging from 23 to 80 meters from the beamline The other configuration considered is the ‘ceiling configuration’ where two tracking layers separated by 1 m are installed directly onto the ceiling of the ATLAS cavern, approximately 23 m above the beamline As in the original ‘shaft configuration’, these two TSs at the bottom of the two service shafts would also need to be removed when they are required by ATLAS Moreover, this configuration would have a larger solid angle coverage than the shaft configuration, offering a broader detection range, making it highly effective for capturing LLP decays that fall between the ATLAS vertex detector’s limits and the cavern ceiling, but this also leads to a smaller decay length acceptance The dominant potential background contribution to ANUBIS is from SM LLPs There are only two electrically neutral SM LLPs that are relevant for ANUBIS given its large active decay volume several metres away from the interaction point: long-lived neutral kaons, K0L, and neutrons, n Hadronic interactions are the dominant background mechanism from SM LLPs in ANUBIS The air-filled active decay volume of ANUBIS reduces the likelihood of a hadronic interaction by a factor of O(104) relative to the tile hadronic calorimeter of ATLAS The potential background contribution from SM LLPs is substantially attenuated by O(105) by the ATLAS detector acting as passive shielding The angular isolation requirements on the DV are essential to remove any background contributions from non-prompt K0L or n production in hadronic showers that are initiated in the ATLAS calorimeters The dominant hadronic interaction backgrounds at ANUBIS are challenging to model using Monte Carlo (MC) simulations at the required precision level A data-driven approach is used to estimate the background contributions The ANUBIS background estimate follows the strategy of the original ANUBIS proposal The conservative background prediction for the ceiling configuration yields Nbgr,ANUBIS ceil.

Mira: = 0.86 × R V =ceil.

Kai: domegadl R V ′=ATLAS domegadl ×fbgr,MS × Nbgr,ATLAS = 182.4 ± 12.2 Signal Modeling and Sensitivity Evaluation The sensitivity of ANUBIS to detect BSM neutral LLPs is evaluated through simulations of their production and decays The primary benchmark model considered involves the Higgs boson decaying into a pair of neutral, scalar LLPs, h → ss, where s denotes a new neutral scalar particle that may be long-lived This analysis considers the dominant Higgs boson production mechanism: gluon-gluon fusion (ggF), which accounts for 88% of Higgs production, with a cross-section of 54.67 pb at √s = 14 TeV The choice of exotic Higgs decays into neutral LLPs as the benchmark is motivated by their prevalence in BSM scenarios, including neutral naturalness

2, 7, 55: and supersymmetric models Sensitivity Results and Comparison The ceiling configuration provides the best sensitivity and can probe Br(h → ss) down to O(10−5) and O(10−6) for the conservative and background-free projections This marks an improvement of over an order of magnitude beyond projected ATLAS and CMS capabilities at the HL-LHC, and surpasses other transverse experiment proposals CODEX-b and MATHUSLA ANUBIS is expected to probe Br(h → ss) down to 1.3 × 10−5 Outlook and Future Work Active R&D efforts aimed at the realisation of the ANUBIS detector are underway The goal is adhering to EU regulations by achieving a global warming potential below 150 times that of CO2 without compromising on detector performance Beyond this work, concerted efforts are underway to map out the sensitivity of the ANUBIS detector to alternative LLP scenarios The primary focus is to map out the sensitivity to PBC benchmark models The goal is adhering to EU regulations by achieving a global warming potential below 150 times that of CO2 without compromising on detector performance Acknowledgments The authors would like to express their gratitude to the ATLAS Collaboration for hosting proANUBIS, facilitating the data taking and data analysis, and provision of consumables Particular thanks go to: Ben Allanach, Cristiano Alpigiani, David Curtin, Albert De Roeck, Miriam Diamond, Erez Etzion, Simon Knapen, Gaurav Kumar, Steven Lowette References

1: R.

Paper summary: Kai: So, to wrap up this discussion on "ANUBIS detector and its sensitivity to neutral long-lived particles", what they’re really saying is that they’ve designed a detector setup that is specifically tailored to find particles with lifetimes longer than ten nanoseconds.

Mira: They've shown how different physical layouts, like the shaft and ceiling configurations, work out differently in terms of sensitivity and what kind of background issues you run into.

Lev: From an engineering standpoint, they’ve put their best projections on the ceiling configuration because it offers better coverage, but they’re being careful about operational headaches when trying to implement that design.

Kai: The paper gives concrete numbers showing that this detector could probe Higgs decays down to one point three times ten to the minus five, which is a step up from current expectations for ATLAS and CMS at the high luminosity phase.

Mira: It’s about pushing the limits of what we can search for in these exotic decay scenarios, giving us new targets for BSM physics based on neutral naturalness and supersymmetric models.

Lev: The limitation they state is that their background estimation relies on a data-driven approach rather than purely Monte Carlo simulations, which means the precision of those background numbers depends heavily on the assumptions built into that data analysis strategy.

Kai: So, overall, ANUBIS is positioning itself as a crucial tool for testing models involving long-lived particles at the LHC, focusing on Higgs decays and providing sensitivity in a way previous experiments couldn't achieve.

Conclusion: Kai: So we've been looking at the ANUBIS detector paper, and now we're getting to the wrap-up—what does this whole thing actually mean for us?

Mira: Yeah, looking at the title 'ANUBIS detector and its sensitivity to neutral long-lived particles', it’s clear they’re talking about finding those weird heavy particles that don't decay right away.

Kai: Exactly. It boils down to these long-lived particles, or LLPs, which are just like dark matter candidates or things from baryogenesis that live a really long time in the detector.

Mira: And the main thing they show is how this new setup, ANUBIS, can see them better than anything currently planned for the high luminosity phase of the LHC.

Lev: From my side, it’s interesting because they’re looking at specific decay channels, like a Higgs boson decaying into these neutral particles with masses around ten to sixty gigaelectronvolts.

Kai: Right, and they're projecting sensitivities that could be as low as one point three times ten to the minus five for some of those decay scenarios.

Mira: That sensitivity is what makes it exciting, because it’s pushing the limits on how far into the exotic physics we can reach with these specific models.

Lev: But you always gotta remember those caveats they mentioned—the background estimation relies on a data-driven method rather than just perfect Monte Carlo simulations.

Kai: Right, so while the projected performance is strong, we have to keep in mind that the real uncertainty is how accurately they model those hadronic interaction backgrounds.

Mira: So, it’s about building a detector that can actually handle these rare signals while dealing with those tricky SM backgrounds at a very high level.

Lev: It tells us what the engineering challenge is—you need precise tracking and isolation to separate that tiny displaced vertex signal from the noise.

Kai: It really frames ANUBIS as a crucial piece of equipment if we want to test these specific BSM scenarios related to neutral naturalness.

Mira: So, it’s not just about finding a particle; it’s about testing the entire structure of physics beyond the Standard Model.

Lev: And that leads us right into how we can actually build something like this, and what those detector layouts mean for real hardware constraints.