Evaluating Generalization and Long-Term Stability of Smartwatch-Based Cuffless Blood Pressure Monitoring
eess.SP
Submitted: 2026-10-29
Updated: 2026-10-29
Comments: Accepted by the 2026 IEEE EMBS International Conference on Biomedical and Health Informatics (BHI 2026)
License: http://creativecommons.org/licenses/by-nc-sa/4.0/
The gist: Smartwatch-based cuffless blood pressure (BP) monitoring is a promising low-burden solution for long-term cardiovascular management…
Terminology
Abstract
Smartwatch-based cuffless blood pressure (BP) monitoring is a promising low-burden solution for long-term cardiovascular management, but practical deployment remains constrained by model complexity, uncertain cross-dataset generalization, and insufficient evidence on long-term tracking stability. This study presents an efficient Signal-Context Gated Fusion Network (SCGBPNet) for cuffless BP estimation from photoplethysmography (PPG) signals. SCGBPNet integrates signal-level representations through self-attention and further incorporates subject-specific contextual information via a compact gated fusion module. On Aurora-BP, SCGBPNet achieved SBP/DBP mean absolute errors (MAEs) of 7.08/4.90 mmHg, compared with 6.44/4.89 mmHg under within-dataset validation on the private smartwatch dataset, indicating a modest within-dataset discrepancy. Cross-dataset transfer from Aurora-BP to the smartwatch dataset increased the MAEs to 8.98/6.47 mmHg, demonstrating substantial cross-dataset degradation. For long-term stability, the proposed method showed low week-to-week performance variation and a low daily decay rate, indicating good stability over a follow-up period of more than one month. Nevertheless, estimation accuracy deteriorated when BP deviated substantially from an individual's baseline. These findings indicate that favorable aggregate MAE alone should not be interpreted as evidence of deployment-ready performance. More systematic and stratified evaluation across dataset settings, BP ranges, and baseline-deviation levels is needed to assess the practical reliability of smartwatch-based cuffless BP monitoring.
Related papers
- Open-H-RF: A Large-Scale Ultrasound Raw Channel Dataset Initiative
- Scalable Attention for 5G NR Channel Estimation
- Low-Altitude Wireless Networks: A Comprehensive Survey
- Sensing-Assisted OFDM with Index Modulation: A Waveform for Optical Wireless Integrated Communication and Localisation
- Iteration-Free Candidate Pruning and an Index-Domain VLSI Architecture for Sort-Free MIMO Box Decoding up to 1024-QAM
- A Foundation Model for Large-Scale Wireless Network Planning, Operation and Optimization