Open-Source Framework for the Visualization, Quantification, and Analysis of 4D Flow and High-Dimensional Magnetic Resonance Images
q-bio.QM
Submitted: 2026-10-28
Updated: 2026-10-30
Comments: These authors contributed equally
License: http://creativecommons.org/licenses/by/4.0/
The gist: Background: Four-dimensional (4D) flow cardiovascular magnetic resonance (CMR) captures 3D anatomy and blood velocity across the cardiac cycle, but current post-processing software is closed…
Abstract
Background: Four-dimensional (4D) flow cardiovascular magnetic resonance (CMR) captures 3D anatomy and blood velocity across the cardiac cycle, but current post-processing software is closed, varies across platforms, and sits outside open-source image-computing frameworks. We developed an open-source framework for the import, visualization, and quantification of 4D flow and other high-dimensional CMR within SlicerHeart, an extension for 3D Slicer. Methods: Import 4D Flow reads vendor DICOM, applies preprocessing, and stores velocities as a time-resolved vector field; Analyze 4D Flow provides measurement planes, streamline and Doppler-like visualization, segmentation propagation, and quantification. Underlying both, we extended the Insight Toolkit to store five- and higher-dimensional arrays. Flow quantification was compared with a commercial package (cvi42) and 2D phase contrast in 13 patients with congenital heart disease across 108 paired regions of interest (Bland-Altman analysis and intraclass correlation coefficients, ICCs). Consensus-recommended processing methods were also implemented as an open-source library with an automated test suite of analytic and CFD phantoms and clinical acquisitions. Results: The modules integrate with 3D Slicer's segmentation, registration, and rendering tools and export velocity fields and geometry for computational modeling. Agreement with cvi42 was close: forward volume bias-0.1 mL (95% limits of agreement 2.2 to-2.3; ICC 0.997), effective volume per minute bias-0.015 L/min (0.21 to-0.24; ICC 0.994). Against 2D phase contrast, forward volume bias (-2.2 mL) and mean absolute percentage error (21.8%) matched cvi42 (-2.1 mL; 21.3%). Conclusions: This open, extensible framework brings 4D flow CMR into an established image-computing ecosystem and agrees closely with a commercial reference; every step can be inspected, reproduced, and improved.
Related papers
- ViroGym: Realistic Large-Scale Benchmarks for Evaluating Viral Proteins
- CellCanon: An Agentic Cellular World Model for Prediction, Explanation, and Observation-Driven Updating
- Probing and steering biology across Boltz-1s trunk-diffusion boundary
- Trajectory Inference of Human Aging from Cross-Sectional DNA Methylation Data
- Bridging the Modality Bottleneck in Pathology MIL through Molecularly Guided Feature Adaptation
- Molecular notation can act as a shortcut in AI benchmark evaluation