Complex Refractive Index Determination via Microspectroscopy Through Magnifying Optics: Challenges and Opportunities
Listen
Radio episode about this paper
Transcript
Introduction to the show: ident: Physics. The day in general physics: instruments, methods and results across the field.
Kai: We're looking at the paper: "Complex Refractive Index Determination via Microspectroscopy Through Magnifying Optics".
Mira: Here's the gist of the paper. Complex refractive index determination via microspectroscopy presents a fast and non-destructive approach for extracting refractive indices from reflectance and transmittance spectra of samples with lateral dimensions down to the micrometer scale <ref:2607.03077#pg2> The authors present a numerical formalism explicitly accounting for the influence of the numerical aperture, allowing for precise retrieval of the refractive index without resorting to dispersion models <ref:2607.03077#pg5>.
Kai: Microspectroscopy Methodology Microspectroscopy enables the assessment of the optical response of multilayer stacks using high-magnification optics with correspondingly large numerical apertures <ref:2607.03077#pg2> This technique couples a spectrometer with a glass fiber to a standard optical microscope, enabling the assessment of reflectance and/or transmittance spectra with a spot size down to 1 µm to 2 µm <ref:2607.03077#pg3>.
Mira: The measurement setup involves an Olympus BX53-MTRF microscope coupled to a Horiba iHR 320 spectrometer, utilizing various objective lenses with different numerical apertures (NAs) <ref:2607.03077#pg2> Linearly polarized light is achieved by inserting a continuously rotatable linear polarizer in the illumination path <ref:2607.03077#pg3>.
Kai: Modeling and Data Processing The numerical procedure involves the inversion of the modeling process for determining layer thickness or crystal axis orientation when refractive indices are known <ref:2607.03077#pg2> The influence of the NA is considered by an objective lens dependent weighting function WTot, which comprises a geometric component based on the objective lens’s NA and a lens-dependent Gaussian shaped component defined by the parameter ζ <ref:2607.03077#pg3>.
Paper summary: Kai: So, looking at the paper "Complex Refractive Index Determination via Microspectroscopy Through Magnifying Optics: Challenges and Opportunities" and the authors Julian Schwarz, Johannes Bauer, Mathias Rommel, and Andreas Hutzler, what's your take on what they actually built here?
Mira: Well, it’s about getting those complex refractive indices from reflectance and transmittance data using microspectroscopy. They show that this is a fast way to do it for samples down to the micrometer scale.
Lev: It seems like they are tackling some real problems with traditional methods, especially when you look at materials like van der Waals crystals or oriented graphite flakes.
Kai: Right, and their approach explicitly accounts for the numerical aperture, which is a big deal because that NA actually changes how much light you capture during the measurement.
Mira: They use a specific numerical formalism to get the refractive index without needing those dispersion models they usually rely on. That’s pretty neat for experimental setups where you don't want to model everything from scratch.
Kai: And the caveat is that for those graphite flakes, the method struggles with probing the out-of-plane refractive indices because they aren't very sensitive to them. That’s a limitation you have to keep in mind for any real hardware application.
Lev: For us, it means if you’re building a device that relies on these nanoscale materials, you need to consider how this method handles those thickness variations and polarization effects. That leads us into how we actually implement this kind of measurement in the lab.
Conclusion: Kai: So, we're wrapping up our look at "Complex Refractive Index Determination via Microspectroscopy Through Magnifying Optics: Challenges and Opportunities" by Julian Schwarz, Johannes Bauer, Mathias Rommel, and Andreas Hutzler.
Mira: This whole paper is about moving the determination of complex refractive indices away from those heavy dispersion models that spectroscopic ellipsometry usually forces you into.
Lev: It focuses on using microspectroscopy to get those indices quickly from reflectance and transmittance spectra measured at the micrometer scale.
Kai: The authors show this numerical formalism explicitly accounts for how much light you capture based on the numerical aperture, or NA, which is a big part of the setup.
Mira: They demonstrate this works for things like transparent glass and absorbing silicon carbide, but they also test it on those tricky flakes of highly oriented pyrolytic graphite and molybdenum trioxide.
Lev: And the caveat there is that for those graphite flakes, the method struggles with probing the out-of-plane refractive indices because they aren't very sensitive to them. That’s a limitation you have to keep in mind for any real hardware application.
Kai: So, it’s promising as an alternative to spectroscopic ellipsometry because of how simple the setup is, but you still get those ambiguities with multiple solution branches if you don't know your material beforehand.
Mira: Exactly, and they discuss ways forward by suggesting we might assume the out-of-plane component gets less important as the flake gets thinner. That’s a key idea for future work.
Lev: For us, it means if you’re building a device that relies on these nanoscale materials, you need to consider how this method handles those thickness variations and polarization effects. That leads us into how we actually implement this kind of measurement in the lab.
Julian Schwarz, Johannes Bauer, Mathias Rommel, Andreas Hutzler
Electron Devices, Friedrich-Alexander-Universität Erlangen-Nürnberg · Fraunhofer Institute for Integrated Systems and Device Technology IISB · Forschungszentrum Jülich GmbH, Helmholtz Institute Erlangen-Nürnberg for Renewable Energy (IET-2)
physics.app-ph
Submitted: 2026-07-03
Updated: 2026-07-03
DOI: 10.1002/smtd.71167
License: http://creativecommons.org/licenses/by/4.0/
Importance score: 79/100
The gist: Complex refractive index determination via microspectroscopy presents a fast and non-destructive approach for extracting refractive indices from reflectance and transmittance spectra of samples with…
Key concepts
- Microspectroscopy
- This technique combines a standard optical microscope with a spectrometer to measure the optical response of samples at very small spots (1-2 µm). It allows researchers to assess reflectance or transmittance spectra on samples with lateral dimensions down to the micrometer scale, providing high-magnification optical data.
- Numerical Formalism Accounting for NA
- The method uses a numerical procedure that specifically incorporates the influence of the numerical aperture (NA) of the objective lens. This is done through a weighting function that combines geometric and Gaussian components, enabling accurate retrieval of refractive indices directly from measurements without relying on pre-existing dispersion models.
- Transfer Matrix Method (TMM)
- The TMM modeling is used to simulate how light interacts with multilayer stacks. It employs Fresnel-based equations to accurately reproduce the detected multiply reflected light, which is crucial for correctly extracting the complex refractive indices from the measured spectra.
Terminology
Summary
Complex refractive index determination via microspectroscopy presents a fast and non-destructive approach for extracting refractive indices from reflectance and transmittance spectra of samples with lateral dimensions down to the micrometer scale <ref:2607. p. 0 Complex Refractive Index Determination via Microspectroscopy
Through Magnifying Optics: Challenges and Opportunities
Julian Schwarz ∗1
, Johannes Bauer 1
, Mathias Rommel ∗2
, and Andreas Hutzler 3
1Electron Devices, Friedrich-Alexander-Universität Erlangen-Nürnberg, Cauerstraße 6,
91058 Erlangen, Germany
2Fraunhofer Institute for Integrated Systems and Device Technology IISB, Schottkystraße 10,
91058 Erlangen, Germany
3Forschungszentrum Jülich GmbH, Helmholtz Institute Erlangen-Nürnberg for Renewable Energy (IET-2),
Cauerstraße 10, 91058 Erlangen, Germany
Abstract
For the design and optimization of optoelectronic devices, accurate knowledge of the complex refractive indices of the constituent materials is essential. Herein, we present a fast
and non-destructive approach for the extraction of the refractive indices from reflectance
and transmittance spectra of samples with lateral dimensions down to the micrometer
scale. Microspectroscopy, based on the combination of a standard optical microscope and
a spectrometer, enables the assessment of the optical response of multilayer stacks using
high-magnification optics with correspondingly large numerical apertures. Employing a
numerical formalism explicitly accounting for the influence of the numerical aperture, allows
for precise retrieval of the refractive index without resorting to dispersion models.Where the paper says it
Where the paper says it
Microspectroscopy Methodology
Microspectroscopy enables the assessment of the optical response of multilayer stacks using high-magnification optics with correspondingly large numerical apertures <ref:2607.03077#pg2> This technique couples a spectrometer with a glass fiber to a standard optical microscope, enabling the assessment of reflectance and/or transmittance spectra with a spot size down to 1 µm to 2 µm <ref:2607. p. 1 An established technique enabling the optical characterization of samples on the micrometer scale is microspectroscopy [26–30], which can be easily implemented by coupling a spectrometer with a glass fiber to a
standard optical microscope [31]. In this way the reflectance and/or transmittance spectra are assesed with a
spot size down to 1 µm to 2 µm [28, 32]. 1 Measurement setup and modus operandi
The schematic of the employed measurement setup is shown in Fig. Reflectance and transmittance were
measured with an Olympus BX53-MTRF microscope coupled to a Horiba iHR 320 spectrometer including
a 1200 grooves/mm diffraction grating. Due to the characteristics of the halogen light sources and the Horiba
Synapse CCD detector, the available spectral range is limited from 440 nm to 950 nm. Linearly polarized
light was achieved by the insertion of a continuously rotatable linear polarizer in the illumination path.Where the paper says it
Where the paper says it
Where the paper says it
Modeling and Data Processing
The numerical procedure involves the inversion of the modeling process for determining layer thickness or crystal axis orientation when refractive indices are known <ref:2607.03077#pg2> The influence of the NA is considered by an objective lens dependent weighting function WTot, which comprises a geometric component based on the objective lens’s NA and a lens-dependent Gaussian shaped component defined by the parameter ζ <ref:2607. p. 3 these AOIs are weighted as per the definition of WTot. WTot comprises a geometric component based on the
objective lens’s NA and a lens-dependent Gaussian shaped component, defined by the parameter ζ, accounting
for potential inhomogeneities of the intensity between the individual AOIs. Besides the incoherent behavior without interference fringes for thick substrates, multiply
reflected light is either completely, partially, or not at all detected. In order to account for this, we apply
our developed approach, denoted partial backside reflectance - micro(spectro)scopy (PBRM) [32], to both
reflectance and transmittance. 5 %, the error for SrTiO3 amounts to ca. As a consequence,
Fresnel-based equations were used to simulate the individual R(αn) and T(αn) to accurately reproduce the
detected multiply reflected light, since this approach allows the different orders of reflected and transmitted
light to be separated in the calculations [47].Where the paper says it
Where the paper says it
Where the paper says it
Material Characterization Results
The method was demonstrated for several sample types, including large-area, homogeneous, optically incoherent samples such as transparent glasses and absorbing 4H-SiC <ref:2607.03077#pg2>. Precise refractive indices matching reference dispersions were extracted for nonabsorbing materials like BF33 and Al2O3 for the 10x and 100x objective lenses <ref:2607. p. 5 S8 demonstrate
the feasibility of the proposed method. So, precise refractive indices matching the reference dispersions were
extracted for these nonabsorbing materials for the 10x and 100x objective lenses. On the contrary, for thick absorbing samples, reflectance and transmittance are required to unambiguously
determine n and k. As an example, a c-plane oriented 4H-SiC sample was investigated, whereby the 4
◦
off-axis cut was neglected.Where the paper says it
Where the paper says it
Anisotropy and Limitations
For flakes of highly oriented pyrolytic graphite (HOPG) and MoO3, anisotropic refractive indices were chosen from literature, and the isotropic approximation was applied for HOPG due to low NA objective lenses <ref:2607.03077#pg5>. The ambiguity of multiple solution branches for n and k in these flakes is a fundamental limitation of the method when no a priori knowledge is available <ref:2607. p. 6 The branch with the higher n,
denoted as branch A, corresponds to the smaller k, and vice versa. Such ambiguity constitutes a fundamental
limitation of the method. Finally, the introduction of linearly polarized light enables the extraction of the refractive indices along the
in-plane crystal axes of biaxial materials. Since linearly polarized light parallel to the in-plane axes effectively
reduces the biaxial behavior to that of a uniaxial material like HOPG, the determined material properties
are again, in principle, isotropic approximations showing thickness-dependent impact of the out-of-plane
component. While the results
prove excellent agreement with values reported in literature, the case of graphite highlights
the limitation for probing the out-of-plane refractive indices due to reduced sensitivity. Finally, we discuss possible extensions towards retrieving the full anisotropic tensor of the
refractive index, establishing the proposed approach as a methodologically sound alternative
to spectroscopic ellipsometry.Where the paper says it
Where the paper says it
Where the paper says it
Conclusion and Future Directions
The proposed method is presented as a promising alternative to state-of-the-art methods for determining material dispersion, with a comparatively simple setup <ref:2607.03077#pg2>. The approach successfully resolves ambiguities in the SixNy thin film by superimposing solution spaces for lenses with different NAs <ref:2607. p. 9 Moreover, the intricate extinction
coefficients of a thick absorbing 4H-SiC substrate were retrieved with high accuracy. The ambiguous solutions
for the dispersion of a SixNy film, due to the interference pattern and the numerical nature of the approach,
could be resolved by superimposing the solution spaces for lenses with different NAs. We
demonstrate the applicability of the proposed method for large-area, homogeneous, optically
incoherent samples such as transparent glasses and absorbing 4H-SiC, for a SixNy
thin film
on glass substrate, and for mechanically exfoliated flakes of highly oriented pyrolytic graphite
and MoO3
, as representatives of uniaxial and biaxial optical anisotropy. While the results
prove excellent agreement with values reported in literature, the case of graphite highlights
the limitation for probing the out-of-plane refractive indices due to reduced sensitivity. In principle, several approaches can be considered for the simultaneous extraction of the in-plane and
out-of-plane complex refractive indices from microspectroscopic measurements. One possibility is based on
the assumption that the influence of the out-of-plane component diminishes with decreasing flake thickness.Where the paper says it
Where the paper says it
Where the paper says it
--- Page 1 ---
Complex Refractive Index Determination via Microspectroscopy Through Magnifying Optics: Challenges and Opportunities <ref:2607.03077#pg2>
Through Magnifying Optics: Challenges and Opportunities <ref:2607.03077#pg2>
Julian Schwarz, Johannes Bauer, Mathias Rommel, and Andreas Hutzler are the authors of this paper <ref:2607.03077#pg2>.
Abstract For the design and optimization of optoelectronic devices, accurate knowledge of the complex refractive indices of the constituent materials is essential <ref:2607. p. 0 Complex Refractive Index Determination via Microspectroscopy
Through Magnifying Optics: Challenges and Opportunities
Julian Schwarz ∗1
, Johannes Bauer 1
, Mathias Rommel ∗2
, and Andreas Hutzler 3
1Electron Devices, Friedrich-Alexander-Universität Erlangen-Nürnberg, Cauerstraße 6,
91058 Erlangen, Germany
2Fraunhofer Institute for Integrated Systems and Device Technology IISB, Schottkystraße 10,
91058 Erlangen, Germany
3Forschungszentrum Jülich GmbH, Helmholtz Institute Erlangen-Nürnberg for Renewable Energy (IET-2),
Cauerstraße 10, 91058 Erlangen, Germany
Abstract
For the design and optimization of optoelectronic devices, accurate knowledge of the complex refractive indices of the constituent materials is essential. Herein, we present a fast
and non-destructive approach for the extraction of the refractive indices from reflectance
and transmittance spectra of samples with lateral dimensions down to the micrometer
scale. Complex Refractive Index Determination via Microspectroscopy
Through Magnifying Optics: Challenges and Opportunities
Julian Schwarz ∗1
, Johannes Bauer 1
, Mathias Rommel ∗2
, and Andreas Hutzler 3
1Electron Devices, Friedrich-Alexander-Universität Erlangen-Nürnberg, Cauerstraße 6,
91058 Erlangen, Germany
2Fraunhofer Institute for Integrated Systems and Device Technology IISB, Schottkystraße 10,
91058 Erlangen, Germany
3Forschungszentrum Jülich GmbH, Helmholtz Institute Erlangen-Nürnberg for Renewable Energy (IET-2),
Cauerstraße 10, 91058 Erlangen, Germany
Abstract
For the design and optimization of optoelectronic devices, accurate knowledge of the complex refractive indices of the constituent materials is essential. Herein, we present a fast
and non-destructive approach for the extraction of the refractive indices from reflectance
and transmittance spectra of samples with lateral dimensions down to the micrometer
scale. Herein, we present a fast
and non-destructive approach for the extraction of the refractive indices from reflectance
and transmittance spectra of samples with lateral dimensions down to the micrometer
scale. Microspectroscopy, based on the combination of a standard optical microscope and
a spectrometer, enables the assessment of the optical response of multilayer stacks using
high-magnification optics with correspondingly large numerical apertures. Microspectroscopy, based on the combination of a standard optical microscope and
a spectrometer, enables the assessment of the optical response of multilayer stacks using
high-magnification optics with correspondingly large numerical apertures. Employing a
numerical formalism explicitly accounting for the influence of the numerical aperture, allows
for precise retrieval of the refractive index without resorting to dispersion models. Employing a
numerical formalism explicitly accounting for the influence of the numerical aperture, allows
for precise retrieval of the refractive index without resorting to dispersion models. We
demonstrate the applicability of the proposed method for large-area, homogeneous, optically
incoherent samples such as transparent glasses and absorbing 4H-SiC, for a SixNy
thin film
on glass substrate, and for mechanically exfoliated flakes of highly oriented pyrolytic graphite
and MoO3
, as representatives of uniaxial and biaxial optical anisotropy. We
demonstrate the applicability of the proposed method for large-area, homogeneous, optically
incoherent samples such as transparent glasses and absorbing 4H-SiC, for a SixNy
thin film
on glass substrate, and for mechanically exfoliated flakes of highly oriented pyrolytic graphite
and MoO3
, as representatives of uniaxial and biaxial optical anisotropy. While the results
prove excellent agreement with values reported in literature, the case of graphite highlights
the limitation for probing the out-of-plane refractive indices due to reduced sensitivity. While the results
prove excellent agreement with values reported in literature, the case of graphite highlights
the limitation for probing the out-of-plane refractive indices due to reduced sensitivity. Finally, we discuss possible extensions towards retrieving the full anisotropic tensor of the
refractive index, establishing the proposed approach as a methodologically sound alternative
to spectroscopic ellipsometry.Where the paper says it
Where the paper says it
Where the paper says it
Where the paper says it
Where the paper says it
Where the paper says it
Where the paper says it
Keywords Microspectroscopy · High numerical aperture · Van der waals materials · Refractive index · Material properties · Transmittance Reflectance
--- Page 2 ---
The precise knowledge of the material properties is vital for the design and optimization of devices build from next-generation materials like van der Waals crystals, exploiting their unique optical and electronic features like tunable bandgaps [1], high carrier mobilities [2], and inherent anisotropy [3–5] for polarization-sensitive devices [6, 7] <ref:2607.03077#pg3>. The complex refractive index, consisting of the real part, the refractive index n, and the imaginary part, the extinction coefficient k, is commonly determined by spectroscopic ellipsometry (SE) [3–12–14], enabling the simultaneous determination of both quantities as well as the thickness [15] <ref:2607. p. 0 For tailoring the characteristics in specific applications employing van der Waals materials
like field-effect transistors [2, 6], photodetectors [8, 9] and waveplates [10, 11], the (complex) refractive
index is a crucial parameter for selecting appropriate materials as it shapes the light-matter interaction in
(opto)electronic devices. The complex refractive index, consisting of the real part, the refractive index n, and the imaginary part,
the extinction coefficient k, is commonly determined by spectroscopic ellipsometry (SE) [3, 12–14], enabling
the simultaneous determination of both quantities as well as the thickness [15]. The complex refractive index, consisting of the real part, the refractive index n, and the imaginary part,
the extinction coefficient k, is commonly determined by spectroscopic ellipsometry (SE) [3, 12–14], enabling
the simultaneous determination of both quantities as well as the thickness [15]. However, the application of
classical SE is limited to large samples with lateral dimensions of several hundred micrometers or more [14, 16].Where the paper says it
Where the paper says it
∗Corresponding authors: julian. p. 0 However, the application of
classical SE is limited to large samples with lateral dimensions of several hundred micrometers or more [14, 16]. ∗Corresponding authors: julian. ∗Corresponding authors: julian. schwarz@fau. Complex Refractive Index Determination via Microspectroscopy
Through Magnifying Optics: Challenges and Opportunities
Julian Schwarz ∗1
, Johannes Bauer 1
, Mathias Rommel ∗2
, and Andreas Hutzler 3
1Electron Devices, Friedrich-Alexander-Universität Erlangen-Nürnberg, Cauerstraße 6,
91058 Erlangen, Germany
2Fraunhofer Institute for Integrated Systems and Device Technology IISB, Schottkystraße 10,
91058 Erlangen, Germany
3Forschungszentrum Jülich GmbH, Helmholtz Institute Erlangen-Nürnberg for Renewable Energy (IET-2),
Cauerstraße 10, 91058 Erlangen, Germany
Abstract
For the design and optimization of optoelectronic devices, accurate knowledge of the complex refractive indices of the constituent materials is essential. Herein, we present a fast
and non-destructive approach for the extraction of the refractive indices from reflectance
and transmittance spectra of samples with lateral dimensions down to the micrometer
scale. Complex Refractive Index Determination via Microspectroscopy
Through Magnifying Optics: Challenges and Opportunities
Julian Schwarz ∗1
, Johannes Bauer 1
, Mathias Rommel ∗2
, and Andreas Hutzler 3
1Electron Devices, Friedrich-Alexander-Universität Erlangen-Nürnberg, Cauerstraße 6,
91058 Erlangen, Germany
2Fraunhofer Institute for Integrated Systems and Device Technology IISB, Schottkystraße 10,
91058 Erlangen, Germany
3Forschungszentrum Jülich GmbH, Helmholtz Institute Erlangen-Nürnberg for Renewable Energy (IET-2),
Cauerstraße 10, 91058 Erlangen, Germany
Abstract
For the design and optimization of optoelectronic devices, accurate knowledge of the complex refractive indices of the constituent materials is essential. Herein, we present a fast
and non-destructive approach for the extraction of the refractive indices from reflectance
and transmittance spectra of samples with lateral dimensions down to the micrometer
scale. rommel@iisb. fraunhofer. fraunhofer. hutzler@fz-juelich. hutzler@fz-juelich. de
1
arXiv:2607. p. 0 hutzler@fz-juelich. de
1
arXiv:2607.Where the paper says it
Where the paper says it
Where the paper says it
Where the paper says it
Where the paper says it
Where the paper says it
Where the paper says it
Where the paper says it
arXiv:2607.03077v1 [physics. p. 0 de
1
arXiv:2607. 03077v1 [physics. 03077v1 [physics. app-ph] 3 Jul 2026Where the paper says it
Where the paper says it
--- Page 3 ---
This requirement is often not met for flakes of van der Waals materials produced by mechanical exfoliation, whose typical lateral dimensions range from a few to a few tens of micrometers <ref:2607.03077#pg3>. Hence, more specialized setups with smaller probe sizes are required for the characterization of such flakes, which can be achieved by imaging SE [17, 18], microspot SE [19, 20], and Fourier plane micro-ellipsometry [21, 22], among others <ref:2607. p. 1 This requirement is often not met for flakes of van der Waals materials produced by mechanical exfoliation,
whose typical lateral dimensions range from a few to a few tens of micrometers. Hence, more specialized
setups with smaller probe sizes are required for the characterization of such flakes, which can be achieved
by imaging SE [17, 18], microspot SE [19, 20], and Fourier plane micro-ellipsometry [21, 22], among others. Hence, more specialized
setups with smaller probe sizes are required for the characterization of such flakes, which can be achieved
by imaging SE [17, 18], microspot SE [19, 20], and Fourier plane micro-ellipsometry [21, 22], among others. But, these advanced methods entail setups with increasing complexity, prolonged measurement times, or
complex data analysis and calibration. But, these advanced methods entail setups with increasing complexity, prolonged measurement times, or
complex data analysis and calibration. Moreover, SE typically relies on optical dispersion models, such as the
Drude–Lorentz [23, 24], Tauc–Lorentz [3, 14], and Sellmeier [25] formalism, especially for the simultaneous
determination of the complex refractive indices and thicknesses of the materials under investigation.Where the paper says it
Where the paper says it
Where the paper says it
An established technique enabling the optical characterization of samples on the micrometer scale is microspectroscopy [26–30], which can be easily implemented by coupling a spectrometer with a glass fiber to a standard optical microscope [31] <ref:2607. p. 1 Moreover, SE typically relies on optical dispersion models, such as the
Drude–Lorentz [23, 24], Tauc–Lorentz [3, 14], and Sellmeier [25] formalism, especially for the simultaneous
determination of the complex refractive indices and thicknesses of the materials under investigation. An established technique enabling the optical characterization of samples on the micrometer scale is microspectroscopy [26–30], which can be easily implemented by coupling a spectrometer with a glass fiber to a
standard optical microscope [31]. An established technique enabling the optical characterization of samples on the micrometer scale is microspectroscopy [26–30], which can be easily implemented by coupling a spectrometer with a glass fiber to a
standard optical microscope [31]. In this way the reflectance and/or transmittance spectra are assesed with a
spot size down to 1 µm to 2 µm [28, 32]. In this way the reflectance and/or transmittance spectra are assesed with a
spot size down to 1 µm to 2 µm [28, 32]. From such measurements, parameters like the thickness [31, 33, 34]
or the complex refractive indices [35–38] can be deduced by comparison with comprehensive modeling. From such measurements, parameters like the thickness [31, 33, 34]
or the complex refractive indices [35–38] can be deduced by comparison with comprehensive modeling. If
linearly polarized light is applied, even the anisotropic optical properties [4, 10, 11, 35, 39] and the orientation
of the crystal axes can be determined. If
linearly polarized light is applied, even the anisotropic optical properties [4, 10, 11, 35, 39] and the orientation
of the crystal axes can be determined. However, the modeling is often based on the assumption of normal
incidence, which may lead to significant errors in the extracted parameters for objective lenses with high
numerical apertures (NAs) and the accompanying large range of angles of incidence (AOIs). However, the modeling is often based on the assumption of normal
incidence, which may lead to significant errors in the extracted parameters for objective lenses with high
numerical apertures (NAs) and the accompanying large range of angles of incidence (AOIs). Additionally,
the utilization of transmittance measurements is underrepresented in literature, whereby especially a lack of
detailed description of the measurement process for such measurements is evident.Where the paper says it
Where the paper says it
Where the paper says it
Where the paper says it
Where the paper says it
Where the paper says it
For this reason, we present an in-depth study on the purely numerical extraction of the (complex) refractive index from reflectance and/or transmittance spectra obtained by microspectroscopy under arbitrary NA <ref:2607. p. 1 Additionally,
the utilization of transmittance measurements is underrepresented in literature, whereby especially a lack of
detailed description of the measurement process for such measurements is evident. For this reason, we present an in-depth study on the purely numerical extraction of the (complex) refractive
index from reflectance and/or transmittance spectra obtained by microspectroscopy under arbitrary NA. For this reason, we present an in-depth study on the purely numerical extraction of the (complex) refractive
index from reflectance and/or transmittance spectra obtained by microspectroscopy under arbitrary NA. Therefore, the extensive modular modeling framework from our previous works [31, 32, 40–42] is employed
and refined to account for transmitted light. Therefore, the extensive modular modeling framework from our previous works [31, 32, 40–42] is employed
and refined to account for transmitted light. In the course of this work, our objective lens dependent
modeling for the influence of the NA [31] is transferred from reflectance to transmittance measurements,
as well as the developed approach accounting for the partial detection of multiply reflected light in thick
transparent substrates with incoherent behavior [32]. In the course of this work, our objective lens dependent
modeling for the influence of the NA [31] is transferred from reflectance to transmittance measurements,
as well as the developed approach accounting for the partial detection of multiply reflected light in thick
transparent substrates with incoherent behavior [32]. On top of that, by incorporating linearly polarized
light in the measurements and implementing it into modeling [42], we demonstrate the determination of the
refractive indices along the different in-plane crystal axes of anisotropic materials. On top of that, by incorporating linearly polarized
light in the measurements and implementing it into modeling [42], we demonstrate the determination of the
refractive indices along the different in-plane crystal axes of anisotropic materials. Lastly, the chances and
limitations of microspectroscopy for the accurate extraction of the full anisotropic tensor of refractive indices
are discussed. Lastly, the chances and
limitations of microspectroscopy for the accurate extraction of the full anisotropic tensor of refractive indices
are discussed. We start with the measurement and modeling procedure for reflectance and, specificially,
transmittance spectra. We start with the measurement and modeling procedure for reflectance and, specificially,
transmittance spectra. Building on this, we present extracted complex refractive indices for several thick
incoherent substrates, both non-absorbing and absorbing, as well as for a SixNy
thin film on a glass substrate,
and flakes of the uniaxial van der Waals material highly oriented pyrolytic graphite (HOPG) and the biaxial
representative MoO3
.Where the paper says it
Where the paper says it
Where the paper says it
Where the paper says it
Where the paper says it
Where the paper says it
Where the paper says it
--- Page 4 ---
In this work, we investigated several optically thick substrates <ref:2607.03077#pg3>. We assumed purely specular reflection and transmission, as all samples were double side polished <ref:2607. p. 1 1 Sample preparation and reference characterization
In this work, we investigated several optically thick substrates. We assumed purely specular reflection and
transmission, as all samples were double side polished. We assumed purely specular reflection and
transmission, as all samples were double side polished. The samples were 500 µm thick BF33 glass wafers
from Schott AG [43], 100 µm AF 32eco thin wafers from Schott AG [44], 500 µm thick Al2O3 windows from
S. We assumed purely specular reflection and
transmission, as all samples were double side polished. The samples were 500 µm thick BF33 glass wafers
from Schott AG [43], 100 µm AF 32eco thin wafers from Schott AG [44], 500 µm thick Al2O3 windows from
S. The samples were 500 µm thick BF33 glass wafers
from Schott AG [43], 100 µm AF 32eco thin wafers from Schott AG [44], 500 µm thick Al2O3 windows from
S. , and 500 µm thick SrTiO3
substrates from CRYSTAL GmbH. , and 500 µm thick SrTiO3
substrates from CRYSTAL GmbH. A SixNy
thin film was deposited
on a BOROFLOAT 33 glass (BF33) wafer as a single-wafer process using plasma-enhanced chemical vapor
deposition (PECVD) at a deposition temperature of 130 ◦C with NH3 and SiH4 as precursors. A SixNy
thin film was deposited
on a BOROFLOAT 33 glass (BF33) wafer as a single-wafer process using plasma-enhanced chemical vapor
deposition (PECVD) at a deposition temperature of 130 ◦C with NH3 and SiH4 as precursors. 500 nm thick layer was applied in two consecutive 250 nm deposition procedures to increase the homogeneity
of the layer thickness. The measurements took place as-deposited without any further heat treatment. These samples were already employed in a previous study [32], where extensive reference characterization of
focused ion beam (FIB) prepared lamellae was performed by high-angle annular dark-field (HAADF)-scanning
transmission electron microscopy (STEM) and energy dispersive X-ray spectroscopy (EDX) and the thickness
of the SixNy film was determined to be 536. hutzler@fz-juelich. de
1
arXiv:2607. These samples were already employed in a previous study [32], where extensive reference characterization of
focused ion beam (FIB) prepared lamellae was performed by high-angle annular dark-field (HAADF)-scanning
transmission electron microscopy (STEM) and energy dispersive X-ray spectroscopy (EDX) and the thickness
of the SixNy film was determined to be 536. The thickness of an n-doped 4H-SiC wafer with the typical 4
◦ off-axis cut normal to the c-plane was
determined to 351. The thickness of an n-doped 4H-SiC wafer with the typical 4
◦ off-axis cut normal to the c-plane was
determined to 351. 5 µm as the average of 5 thickness measurements at different positions on the wafer
obtained by a Logitech CG10 contact measurement gauge. 5 µm as the average of 5 thickness measurements at different positions on the wafer
obtained by a Logitech CG10 contact measurement gauge. Flakes of HOPG and MoO3 were mechanically
exfoliated in atmosphere and transferred onto 500 µm thick BF33 glass substrates. Flakes of HOPG and MoO3 were mechanically
exfoliated in atmosphere and transferred onto 500 µm thick BF33 glass substrates. The thickness of the
flakes was determined by atomic force microscopy (AFM) measurements using a Bruker Dimension ICON in
intermittent-contact mode.Where the paper says it
Where the paper says it
Where the paper says it
Where the paper says it
Where the paper says it
Where the paper says it
Where the paper says it
Where the paper says it
Where the paper says it
Where the paper says it
Where the paper says it
Where the paper says it
--- Page 5 ---
The schematic of the employed measurement setup is shown in Fig. 1a <ref:2607. p. 0 hutzler@fz-juelich. de
1
arXiv:2607. 1 Measurement setup and modus operandi
The schematic of the employed measurement setup is shown in Fig. Reflectance and transmittance were
measured with an Olympus BX53-MTRF microscope coupled to a Horiba iHR 320 spectrometer including
a 1200 grooves/mm diffraction grating. Reflectance and transmittance were
measured with an Olympus BX53-MTRF microscope coupled to a Horiba iHR 320 spectrometer including
a 1200 grooves/mm diffraction grating. The signal is collected with the center fiber of a fiber bundle,
which has a diameter of 200 µm. The signal is collected with the center fiber of a fiber bundle,
which has a diameter of 200 µm. Due to the characteristics of the halogen light sources and the Horiba
Synapse CCD detector, the available spectral range is limited from 440 nm to 950 nm. Due to the characteristics of the halogen light sources and the Horiba
Synapse CCD detector, the available spectral range is limited from 440 nm to 950 nm. Linearly polarized
light was achieved by the insertion of a continuously rotatable linear polarizer in the illumination path. Linearly polarized
light was achieved by the insertion of a continuously rotatable linear polarizer in the illumination path. For
transillumination measurements, an achromatic and aplanatic Olympus U-AAC universal condenser was used. For
transillumination measurements, an achromatic and aplanatic Olympus U-AAC universal condenser was used. All utilized objective lenses are listed in Tab. All utilized objective lenses are listed in Tab. 1 together with their NAs and the corresponding diameters of
the measurement spot on the sample, defined by the respective magnification and the fiber diameter. Objective lens 10x 50xUL1 100xUL1 100x
NA 0. 90
Spot diameter/µm 20 4 2 2
In general, the field stop was set to the smallest size to reduce stray light [26, 32]. 90
Spot diameter/µm 20 4 2 2
In general, the field stop was set to the smallest size to reduce stray light [26, 32]. To account for background
noise in reflectance, the spectrum of an ultra-low reflecting flock sheet from Musou Black was measured [42]. To account for background
noise in reflectance, the spectrum of an ultra-low reflecting flock sheet from Musou Black was measured [42]. In transmittance, the background signal was isolated by measuring the spectrum with the light path to the
detector blocked. In contrast, a 100 % transmittance reference was used by aligning condenser and objective lens
relative to each other without a sample in between. All measurements were averaged over 10 acquisitions. All measurements were averaged over 10 acquisitions. For focusing on the upper surface of the sample in both illumination modes, the objective lens was focused by
moving the stage until the image of the field diaphragm was brought into sharp focus. For focusing on the upper surface of the sample in both illumination modes, the objective lens was focused by
moving the stage until the image of the field diaphragm was brought into sharp focus. In transmission mode,
the condenser was subsequently adjusted so that the image of its field diaphragm was also sharply visible,
after the light source in the epi-illumination path had been disabled. In transmission mode,
the condenser was subsequently adjusted so that the image of its field diaphragm was also sharply visible,
after the light source in the epi-illumination path had been disabled. In general, the aperture diaphragm
was fully opened in epi-illumination and in transillumination the condenser aperture was adjusted to match
the NA of the objective lens to ensure the same range of AOIs in both illumination modes. However, the
illumination through a thick substrate by the condenser causes spherical aberrations due to the refractive
index mismatch between the substrate and the surrounding air [45, 46]. This phenomenon is especially
pronounced for the 100x objective lens with the highest NA of 0. This phenomenon is especially
pronounced for the 100x objective lens with the highest NA of 0. 90 and the ocurring high AOIs, which is why
the condenser aperture was reduced to an effective NA of 0. 90 and the ocurring high AOIs, which is why
the condenser aperture was reduced to an effective NA of 0. 60 for the transmittance measurements with this
objective lens to mitigate the influence of spherical aberrations (cf.Where the paper says it
Where the paper says it
Where the paper says it
Where the paper says it
Where the paper says it
Where the paper says it
Where the paper says it
Where the paper says it
Where the paper says it
Where the paper says it
Where the paper says it
Where the paper says it
Where the paper says it
Where the paper says it
Where the paper says it
Where the paper says it
Where the paper says it
Where the paper says it
--- Page 6 ---
Fig. 1: a) Schematic of the employed measurement setup. p. 2 2 Microspectroscopic measurements and modeling
2. 1 Measurement setup and modus operandi
The schematic of the employed measurement setup is shown in Fig. 2 Modeling framework
Fig. 1b shows the flowchart of the numerical procedure for extracting the (complex) refractive indices from
measured reflectance and transmittance spectra. 2 Modeling framework
Fig. 1b shows the flowchart of the numerical procedure for extracting the (complex) refractive indices from
measured reflectance and transmittance spectra.Where the paper says it
Where the paper says it
Where the paper says it
Flowchart of the numerical procedure for extracting the (complex) refractive indices from measured reflectance and/or transmittance spectra <ref:2607.03077#pg2>.
--- Page 8 ---
Fig. 2: (a) Measured reflectance (R) and transmittance (T) spectra of a 351. p. 5 The
simulations accurately replicate the measurements. 2: (a) Measured reflectance (R) and transmittance (T) spectra of a 351. 2: (a) Measured reflectance (R) and transmittance (T) spectra of a 351. 5 µm thick 4H-SiC sample for the
10x/NA 0. 5 µm thick 4H-SiC sample for the
10x/NA 0. 25 objective lens and corresponding modeled spectra, calculated using isotropic optical constants
(n, k) from Khadivianazar et al. hutzler@fz-juelich. de
1
arXiv:2607. [56] as reference. Extracted solution space, smoothed mean of the solution
space, analytical solution based on the equations of Nichelatti [58], and the reference values by Khadivianazar
et al.Where the paper says it
Where the paper says it
Where the paper says it
Where the paper says it
Where the paper says it
Green — the paper says it, and the page is printed. Red — no passage carries it, so treat that sentence as unverified. The same check runs on your own text: check a summary against its source, $5.
Improvements for AI systems
-
Automated extraction of complex refractive indices from microspectroscopy data can be performed without relying on dispersion models like Drude-Lorentz or Tauc-Lorentz by using a numerical formalism that explicitly accounts for the influence of the numerical aperture (NA).
-
The improved system can accurately determine the thickness and complex refractive indices of multilayer stacks and thick transparent substrates, such as a SixNy thin film on glass, by transferring objective lens dependent modeling from reflectance to transmittance measurements.
-
The AI system can resolve ambiguities in extracting refractive indices for flakes of van der Waals materials like HOPG and MoO3 by superimposing the solution spaces obtained from different objective lenses or analyzing samples with varying thicknesses.
-
The system can determine refractive indices along the in-plane crystal axes of biaxial materials like MoO3 by incorporating linearly polarized light measurements into the modeling framework, enabling the determination of material properties that are at least uniaxial approximations.
-
The AI system can estimate isotropic refractive indices for anisotropic samples like HOPG by utilizing solution branch A, which corresponds to the smaller extinction coefficient k, and comparing results with literature data where available.
Abstract
For the design and optimization of optoelectronic devices, accurate knowledge of the complex refractive indices of the constituent materials is essential. Herein, we present a fast and non-destructive approach for the extraction of the refractive indices from reflectance and transmittance spectra of samples with lateral dimensions down to the micrometer scale. Microspectroscopy, based on the combination of a standard optical microscope and a spectrometer, enables the assessment of the optical response of multilayer stacks using high-magnification optics with correspondingly large numerical apertures. Employing a numerical formalism explicitly accounting for the influence of the numerical aperture, allows for precise retrieval of the refractive index without resorting to dispersion models. We demonstrate the applicability of the proposed method for large-area, homogeneous, optically incoherent samples such as transparent glasses and absorbing 4H-SiC, for a SixNy thin film on glass substrate, and for mechanically exfoliated flakes of highly oriented pyrolytic graphite and MoO3, as representatives of uniaxial and biaxial optical anisotropy. While the results prove excellent agreement with values reported in literature, the case of graphite highlights the limitation for probing the out-of-plane refractive indices due to reduced sensitivity. Finally, we discuss possible extensions towards retrieving the full anisotropic tensor of the refractive index, establishing the proposed approach as a methodologically sound alternative to spectroscopic ellipsometry.
Related papers
- Twistsonics: engineering acoustic topological textures in moire sound lattices
- Vibe-FDTR: An agent-oriented framework for reproducible frequency-domain thermoreflectance data analysis
- Principles of Use of Tensile J-Curve Materials in Antagonistic Arrangements
- Nonreciprocal Radiation in Time-Periodic Topological Quadrupole Lattices
- Impact of Structural Design on Magneto-Mechanical Resonators: The Case of a Jewel Bearing Variant
- Measurement and Modeling of Structure-Induced Surface Scattering on Terahertz Channel