An Enhanced Submodule for Modular Multilevel Converters With DC Fault-Clearing Capability

arXiv:2606.22469 · eess.SY, cs.SY · Submitted 2026-06-21 · Read on arXiv

Listen

Radio episode about this paper

Transcript

Introduction to the show: ident: Robotics Radio. Generated commentary on the latest robotics and control papers.

Rosa: I'm Rosa.

Dev: And I'm Dev, here with Taro.

Rosa: We're looking at the paper: "An Enhanced Submodule for Modular Multilevel Converters With DC Fault-Clearing Capability".

Dev: Here's the gist of the paper. Modular multilevel converter (MMC) has been successfully applied in various power electronic systems owing to its high efficiency, scalability, and superior output performance <ref:2606.22469#pg2> The diode-clamp submodule (DCSM) addresses this limitation by providing DC fault ride-through capability <ref:2606.22469#pg2> To overcome this drawback, an enhanced SM is proposed in this paper <ref:2606.22469#pg2>.

Rosa: Proposal and Design of the Enhanced Submodule The proposed submodule is a two-port circuit network consisting of three fully controlled switches S1–S3, three diodes D1–D3, and two capacitors C1, C2 where C1 > C2 <ref:2606.22469#pg3>.

Dev: The switches and diodes form a half-bridge configuration where the upper arm comprises switch S1 with an anti-parallel connected diode D1, while the lower arm consists of switches S2 and S3 connected in anti-series, each with an anti-parallel diode <ref:2606.22469#pg4>.

Rosa: The proposed SM features three operating modes similar to those of the conventional HBSM, namely, the inserted mode, the bypassed mode, and the blocked mode <ref:2606.22469#pg4>.

Paper summary: Rosa: So, to wrap up what we just covered about this paper, the authors are presenting an enhanced half-bridge submodule for modular multilevel converters that has direct current fault clearing capability <ref:2606.22469#pg1>.

Dev: The main implication is that this proposed submodule can autonomously suppress fault currents and resume normal operation right after a fault clears without needing those extra external protection devices we usually have to add <ref:2606.22469#pg1>.

Taro: It really reduces the overall system complexity and capital cost because they achieve greater energy storage capability while requiring only a smaller total capacitance and one fewer diode than the DCSM <ref:2606.22469#pg1>.

Rosa: So, when you look at this paper by Yu Liu, Shengbo Zhang, and Yating Yuan titled "An Enhanced Submodule for Modular Multilevel Converters With DC Fault-Clearing Capability," it’s about making the core building block of these converters more robust against severe short circuits <ref:2606.22469#pg1>.

Dev: The functionality they validated experimentally shows that this topology works as intended, allowing for reliable fault ride-through in a three-phase MMC setup <ref:2606.22469#pg1>.

Conclusion: Rosa: So we've looked at this paper, "An Enhanced Submodule for Modular Multilevel Converters With DC Fault-Clearing Capability," and it basically wraps up by saying they've built a better building block for those modular multilevel converters.

Dev: They’re focusing on how to give that core submodule the ability to handle direct current faults all by itself, without needing those extra external protection gadgets you usually have to bolt onto the system.

Taro: What this means for us is that we can potentially make these power systems more reliable and less dependent on complex, separate safety circuits when dealing with sudden short circuits.

Rosa: It’s about taking the energy storage part of the converter, which is often a weak spot during faults, and making it actively fight back against those fault currents through its own internal operation.

Dev: The authors showed that this enhanced submodule uses three different operating modes—inserted, bypassed, and blocked—to manage what happens when a fault current hits the system.

Taro: Specifically, in that blocked mode during a short circuit, they found that the way the voltage is boosting actually fights the direction of the fault current itself.

Rosa: That's really interesting because it suggests we can suppress those initial large currents before they even have a chance to damage other parts of the converter.

Dev: And from an engineering standpoint, their comparison shows this new design requires less total capacitance and one fewer diode than previous designs for the same amount of energy storage capacity.

Taro: So we're talking about reducing the physical size and component count while increasing that critical fault ride-through capability simultaneously.

Rosa: That’s a big deal because it lowers both the capital cost of building these converters and increases their operational lifespan under harsh conditions.

Dev: The experimental validation confirmed they can handle these DC short-circuit faults on a three phase modular multilevel converter setup without any outside devices at all.

Taro: So, this moves the goalpost on how robust we can design the fundamental components of these high-power systems.

Shenzhen Technology University · University of Waterloo

eess.SY, cs.SY

Submitted: 2026-06-21

Updated: 2026-11-06

Comments: 9 pages, 17 figures

License: http://creativecommons.org/licenses/by/4.0/

Importance score: 67/100

The gist: Modular multilevel converter (MMC) has been successfully applied in various power electronic systems owing to its high efficiency, scalability…

Key concepts

Modular Multilevel Converter (MMC)
An MMC is a power electronic system known for its high efficiency and scalability. It uses multiple voltage levels to synthesize a desired output voltage, making it suitable for various power applications.
Diode-Clamp Submodule (DCSM)
The original submodule addressed DC fault ride-through but required more components. The proposed enhanced SM aims to improve performance while reducing the component count and increasing energy storage capacity compared to the DCSM.
Blocked Mode
In this specific operating mode, all switches are turned off during a short-circuit fault. This configuration causes the submodule's voltage boost direction to oppose the incoming fault current, effectively suppressing it and allowing normal operation to resume after the fault clears.

Terminology

Summary

Modular multilevel converter (MMC) has been successfully applied in various power electronic systems owing to its high efficiency, scalability, and superior output performance <ref:2606. p. 0

Where the paper says it

JOURNAL OF LATEX CLASS FILES, VOL. 8, JUNE 2026 1 An Enhanced Submodule for Modular Multilevel Converter with DC Fault Ride-Through Capability Yu Liu, Shengbo Zhang, and Yating Yuan Abstract—Modular multilevel converter (MMC) has been successfully applied in various power electronic systems owing to its high efficiency, scalability, and superior output performance.

22469#pg2> The diode-clamp submodule (DCSM) addresses this limitation by providing DC fault ride-through capability <ref:2606. p. 0
Where the paper says it

Although the half-bridge submodule (HBSM) is widely used in MMCs for its structural simplicity, it is incapable of handling direct-current (DC) short-circuit faults. The diode-clamp submodule (DCSM) addresses this limitation by providing DC fault ride-through capability.

22469#pg2> To overcome this drawback, an enhanced SM is proposed in this paper <ref:2606. p. 0
Where the paper says it

However, because its two identical capacitors are connected in series, the equivalent capacitance is halved. To overcome this drawback, an enhanced SM is proposed in this paper.

22469#pg2>.

Proposal and Design of the Enhanced Submodule

The proposed submodule is a two-port circuit network consisting of three fully controlled switches S1–S3, three diodes D1–D3, and two capacitors C1, C2 where C1 > C2 <ref:2606.22469#pg3>. The switches and diodes form a half-bridge configuration where the upper arm comprises switch S1 with an anti-parallel connected diode D1, while the lower arm consists of switches S2 and S3 connected in anti-series, each with an anti-parallel diode <ref:2606. p. 1

Where the paper says it

8, JUNE 2026 2 two capacitors C1, C2 where C1 > C2. The switches and diodes form a half-bridge configuration: the upper arm comprises switch S1 with an anti-parallel connected diode D1, while the lower arm consists of switches S2 and S3 connected in anti-series, each with an anti-parallel diode.

22469#pg4>. The proposed SM features three operating modes similar to those of the conventional HBSM, namely, the inserted mode, the bypassed mode, and the blocked mode <ref:2606. p. 1
Where the paper says it

Circuit topology of the proposed SM. The proposed SM features three operating modes similar to those of the conventional HBSM, namely, the inserted mode, the bypassed mode, and the blocked mode.

22469#pg4>.

Operating Modes of the Proposed Submodule

The SM operates in three distinct modes:

  1. Inserted Mode: In this mode, S1 and S3 are turned on, whereas S2 is turned off, and both capacitors are connected in parallel <ref:2606. p. 1

    Where the paper says it

    Mode 1: Inserted Mode In this mode, S1 and S3 are turned on, whereas S2 is turned off. Consequently, the upper arm conducts while the lower arm is blocked, and both capacitors are connected in parallel and inserted into the external circuit.

    22469#pg5>. During normal operation, the two capacitors are effectively connected in parallel regardless of the direction of iSM. p. 1
    Where the paper says it

    During normal operation, these voltage drops are much smaller than the capacitor voltages, yielding vSM ≈ vc1 ≈ vc2 in this mode. Therefore, the two capacitors are effectively connected in parallel regardless of the direction of iSM.

  2. Bypassed Mode: When S1 is turned off and S2 and S3 are turned on, the upper arm is blocked while the lower arm conducts, and iSM does not flow through the capacitors. p. 1

    Where the paper says it

    Current path in the SM during normal operation: (a) inserted mode; (b) bypassed mode. Mode 2: Bypassed Mode When S1 is turned off and S2 and S3 are turned on, the upper arm is blocked while the lower arm conducts, and the SM operates in the bypassed mode.

    In this mode, C1 and C2 are always connected in parallel regardless of the direction of iSM. p. 1
    Where the paper says it

    Hence, the capacitors are bypassed and their voltages remain constant, neglecting losses. In this mode, C1 and C2 are always connected in parallel regardless of the direction of iSM, and vSM can be calculated as follows: vSM = vs2 + vd3 = vs3 + vd2 ≈ 0.

  3. Blocked Mode: When all switches S1–S3 are turned off, the SM operates in the blocked mode which can be adopted during a short-circuit fault. p. 1

    Where the paper says it

    Mode 3: Blocked Mode When all switches S1–S3 are turned off, the SM operates in the blocked mode. This mode can be adopted during the startup process to charge the capacitor voltages to the preset value, or when a short-circuit fault occurs.

    In this mode, if iSM is a fault current, it will be suppressed because the boosting direction of vSM opposes the direction of iSM. p. 2
    Where the paper says it

    In this case, the two capacitors are connected in parallel, and vSM can be calculated as eq. If iSM is a fault current, it will be suppressed because the boosting direction of vSM opposes the direction of iSM in this mode.

Performance Comparison with Existing Topologies

The proposed SM offers advantages over the DCSM in terms of energy storage capacity and component count. Specifically, for the same energy storage capacity, the proposed SM requires a smaller total capacitance and one fewer diode than the DCSM <ref:2606. p. 0

Where the paper says it

Similar to the DCSM, the proposed SM can autonomously suppress DC fault currents and resume normal operation after fault clearance. More importantly, for the same energy storage capacity, the proposed SM requires a smaller total capacitance and one fewer diode than the DCSM, thereby reducing the overall capital cost of the MMC.

22469#pg2>. Furthermore, Ceq,p = C1 + C2 is greater than Ceq,d = 1/2C1 of the DCSM due to parallel connection in Modes 1 and 2. p. 1
Where the paper says it

, C1 = C2, resulting in an equivalent capacitance of Ceq,d = 1 2C1. Therefore, for the same individual capacitors, Ceq,p > Ceq,d, indicating that the proposed SM offers greater energy storage capability than the DCSM.

This means the proposed SM requires only 25% of the total capacitance required by the DCSM to achieve the same equivalent capacitance. p. 1
Where the paper says it

Therefore, for the same individual capacitors, Ceq,p > Ceq,d, indicating that the proposed SM offers greater energy storage capability than the DCSM. Equivalently, to achieve the same equivalent capacitance, the proposed SM requires only 25% of the total capacitance required by the DCSM, thereby reducing the capacitor cost in the MMC.

Experimental Validation and Fault Ride-Through

The proposed SM topology was verified through an experiment applied to a three-phase MMC During a DC fault, once the current exceeds a preset threshold value Ith arm, the SMs enter Mode 3 by turning off all IGBTs. In this blocked mode, vc2 decreases while vc1 increases because the two capacitors are connected in anti-series. p. 2

Where the paper says it

Thus, vSM is initially zero when the SM transitions from either of these modes to Mode 3. Once blocked, vc2 decreases while vc1 increases because the two capacitors are connected in anti-series, resulting in a negative vSM that continuously decreases.

This results in a voltage vSM that opposes the fault current, forcing the arm currents to decay. p. 3
Where the paper says it

Therefore, once the SM is blocked, vc2 decreases while vc1 increases, as illustrated by the capacitor voltages of SM1 in Fig. Because the two capacitors are connected in anti-series, the voltage across the SM becomes increasingly negative and opposes the fault current, forcing the arm currents to decay, as shown in Fig.

The experiment confirmed that the proposed SM can ride through DC short-circuit faults without external protection devices. p. 3
Where the paper says it

The arm currents, AC-side currents, and capacitor voltages automatically return to their pre-fault levels, as shown in Fig. This confirms that the proposed SM topology can ride through DC short-circuit faults without external protection devices.

Conclusion

The paper presents an enhanced HBSM with DC fault ride-through capability for MMCs. The proposed SM can autonomously suppress fault currents and resume normal operation after fault clearance without relying on additional external protection devices. p. 3

Where the paper says it

The topology and operating modes of the proposed SM are described in detail, and its performance is experimentally validated. Similar to the DCSM, the proposed SM can autonomously suppress fault currents and resume normal operation after fault clearance without relying on additional external protection devices.

This topology reduces system complexity and overall capital cost of the MMC by requiring a smaller total capacitance while offering greater energy storage capability and using one fewer diode than the DCSM. p. 3
Where the paper says it

Unlike the DCSM, however, the proposed SM requires a smaller total capacitance while offering greater energy storage capability, and each proposed SM uses one fewer diode than the DCSM. These advantages help reduce the system complexity and overall capital cost of the MMC.

The functionality of the proposed SM is experimentally validated. p. 0
Where the paper says it

In addition, the proposed SM requires one fewer diode than the DCSM, thereby lowering the overall MMC capital cost. The topology and the operating modes of the proposed SM are described in detail, and its functionality is experimentally validated.

Green — the paper says it, and the page is printed. Red — no passage carries it, so treat that sentence as unverified. The same check runs on your own text: check a summary against its source, $5.

Improvements for AI systems

  1. Improved AI systems can operate reliably in DC grid applications by integrating a proposed submodule topology that autonomously suppresses DC fault currents and restores normal operation without external protection devices.

  2. The improved system achieves reduced capital cost compared to existing fault-handling modules by requiring one fewer diode than the DCSM and utilizing a smaller total capacitance for the same energy storage capacity.

  3. The enhanced submodule allows for greater energy storage capability than the DCSM, as "for the same individual capacitors, Ceq,p > Ceq,d," which translates to requiring only 25 percent of the total capacitance needed by the DCSM to achieve equivalent performance.

Abstract

Modular multilevel converter (MMC) has been successfully applied in various power electronic systems owing to its high efficiency, scalability, and superior output performance. Although the half-bridge submodule (HBSM) is widely used in MMCs for its structural simplicity, it is incapable of handling direct-current (DC) short-circuit faults. The diode-clamp submodule (DCSM) addresses this limitation by providing DC fault ride-through capability. However, because its two identical capacitors are connected in series, the equivalent capacitance is halved. To overcome this drawback, an enhanced SM is proposed in this paper. For the same energy storage capacity, the proposed SM reduces the total required capacitance by 75% compared with the DCSM. In addition, the proposed SM requires one fewer diode than the DCSM, thereby lowering the overall MMC capital cost. The topology and the operating modes of the proposed SM are described in detail, and its functionality is experimentally validated. The results demonstrate that the proposed SM can suppress DC fault currents and restore normal operation without additional external protection devices.

Related papers