Neutron Capture Information in Improving IBD Angular Resolution
Listen
Radio episode about this paper
Transcript
Introduction to the show: ident: High Energy Physics: Phenomenology. The day in particle phenomenology: models, signatures and constraints.
Kai: I'm Kai.
Mira: And I'm Mira, here with Lev.
Kai: We're looking at the paper: "Neutron Capture Information in Improving IBD Angular Resolution".
Mira: Here's the gist of the paper. Improving the angular resolution of IBD events using neutron capture information in Super-Kamiokande investigates how incorporating neutron capture data can statistically enhance neutrino directionality in Inverse Beta Decay (IBD) events, which is crucial for improving event reconstruction in water Cherenkov detectors The paper aims to study the possibilities of using neutron capture information to improve the angular resolution of IBD event reconstruction in water Cherenkov detectors.
Kai: This is motivated by the fact that while positron directions are often isotropic at low energies, neutron capture information could potentially provide additional information that allows better event reconstruction.
Mira: The authors use Geant4 to simulate neutron propagation in water and show that in a wide range of neutrino energies from about 10 MeV to several hundred MeV, neutron capture information could statistically enhance the neutrino directionality, compared to positron-only inference, even with neutron diffusion considered.
Kai: Experimental Setup and Simulation The study focuses on Super-Kamiokande (SK), a 50-kton water Cherenkov detector in Japan, which is undergoing an upgrade to incorporate 0.1% Gd into the current detector.
Title and authors: Kai: The paper we're looking at today is called "Neutron Capture Information in Improving IBD Angular Resolution". It’s a study focused on using neutron capture data to make Inverse Beta Decay events look more directional.
Mira: Right, it’s about how incorporating the information from neutrons can statistically help us improve the angular resolution of those Inverse Beta Decay events in water Cherenkov detectors.
Lev: From an engineering perspective, I'm thinking about how much overhead this kind of extra data adds to our existing reconstruction pipeline.
Kai: The authors are Qishan Liu and Kenny C. Y. Ng, working at the Chinese University of Hong Kong and the Chinese Academy of Sciences, Beijing. They’re looking at a fifty-kton water Cherenkov detector called Super-Kamiokande that is being upgraded with gadolinium <ref:2606.12155#pg2,a 50-kton water Cherenkov detector>.
Mira: So it’s important to know they are working on SK, which is getting doped with gadolinium sulfate octahydrate to increase neutron capture efficiency.
Lev: I'm interested in knowing the specific context of their work there, because the physics environment matters a lot for these kinds of simulations.
Kai: They’re specifically looking at how that improved neutron capture efficiency, which goes from about fifty percent at zero point zero one one percent concentration to seventy-five percent at zero point zero three percent concentration, could potentially provide extra information for event reconstruction <ref:2606.12155#pg2>.
Mira: So the core question is whether this extra neutron tagging allows us to get better directionality when we compare it against just the positron information we usually have.
Lev: I’m wondering if their simulation setup reflects the real-world conditions of those doping processes, because that’s where most of the assumptions live in these kinds of papers.
Kai: They are using Geant4 to simulate neutron diffusion in both pure water and Gd-doped water, which is essential because diffusion is what makes event-by-event reconstruction so difficult.
Mira: So they’re using simulation to bridge the gap between the hard physics and the actual detector response we see in data.
Lev: I want to know what aspect of that simulation they find most challenging—is it modeling the neutron interactions or something else?
Kai: They focused on including specific modules like G4HadronElasticPhysicsHP and G4HadronPhysicsFTFP BERT HP to model the neutron capture, but they also ran into a problem where Geant4 simulation overestimated the thermal motion of hydrogen atoms in pure water.
Mira: That overestimation is something they had to account for because it caused an underestimation of hydrogen capture compared to Gd, which is a significant detail.
Lev: So that means their baseline comparison between pure and doped water isn't perfectly clean; the physics model itself has some inherent bias we have to consider.
Kai: They are looking at how these factors all combine to affect the final neutrino directionality when they match the neutron capture angle with the positron energy and angle to estimate a new direction.
Title and authors: Mira: That matching process is where they are trying to see if the statistical enhancement they claim actually shows up in practice, or if it’s just a theoretical effect.
Lev: So, what’s their main finding here? Are we talking about a clear boost in resolution, or is it something more subtle?
Kai: They found that even with neutron diffusion present, the inclusion of neutron capture information demonstrably enhances the reconstruction of neutrino directionality, and for a thirty MeV neutrino energy, the average cosine of Psi is about zero point two eight.
Mira: That number gives a clear idea of how much directional information they are actually recovering in that specific case when comparing it to just using positron direction.
Lev: So if we look at the overall picture, this suggests that incorporating this neutron data can statistically boost our ability to reconstruct the neutrino direction even in a noisy environment.
Kai: They also found a split based on energy: for neutrinos below forty MeV, they found that using only the neutron capture position alone yields a superior angular reconstruction performance compared to the combined method using both signals.
Mira: So they’re suggesting that you might need to tailor your reconstruction strategy based on the neutrino energy regime you are dealing with.
Lev: That's practical advice for experimental design; it tells us when one data source is better than trying to combine them.
Kai: The paper also flagged a limitation, saying that if the vertex resolution is thirty centimeters on both vertices, then directionality gets lost and there’s no improvement over just using positron-only results.
Mira: That’s the big caveat—if your detector resolution is poor, all this statistical enhancement from the neutron capture information becomes negligible.
Lev: So for any real hardware we build, that means we really need to focus on improving vertex resolution if we want to realize these gains in neutrino direction reconstruction.
Kai: They are also discussing the idea of simplifying the reconstruction by suggesting that instead of reconstructing two vertices and finding a vector between them, a single algorithm to directly reconstruct the neutron capture vector might reduce detector requirements.
Mira: That’s an interesting algorithmic suggestion; it means we might not need as much precise vertex information if we can just work with one combined measurement.
Lev: I'm leaning toward that idea because simpler algorithms are usually easier to implement in real-time systems, and that could reduce the computational load on our error correction routines.
Kai: So they’re giving us a direction for how to think about this: focus on the neutron capture angle relative to the positron vector, not necessarily reconstructing two separate vertices.
Mira: And it’s important to remember that this work is just a first step in considering how we can better reconstruct neutrino information in Super-Kamiokande Gd.
Lev: It sets a clear benchmark for what we need to achieve if we want to move toward the next generation of detectors like Hyper-Kamiokande, which is exactly what this paper suggests.
The paper's summary: Kai: So, summarizing the main point of "Neutron Capture Information in Improving IBD Angular Resolution," it’s about using neutron capture data to get better directionality when reconstructing Inverse Beta Decay events.
Mira: They show that the core idea is that because positron directions are often isotropic at low energies, we need to look for additional directional clues from neutrons.
Lev: So, the paper is basically arguing that the neutron capture information could statistically enhance neutrino directionality even when event-by-event reconstruction is hard due to neutron diffusion.
Kai: Exactly. They use simulations to show that neutrons retain some directional information after diffusion, and this effect is slightly better in Gd-loaded water compared to pure water.
Mira: And they quantify this enhancement by showing that combining the neutron capture information with the positron information leads to a better result than using just the positron direction or just the neutron capture position alone in certain conditions.
Lev: So, it’s not just that we have more data; it’s about how we combine these different pieces of data to make a statistically significant improvement in what we reconstruct.
Kai: They are investigating all these factors together, including the detector resolutions and the energy dependencies to see where this method actually works best.
Mira: And they found that while combining both signals is better with perfect detector resolution, you have to be careful because when you introduce real-world resolutions, like a thirty centimeter vertex resolution, it can wash out all that gain.
Lev: So the summary is that the benefit of the neutron information isn't guaranteed; it depends heavily on how well those detector resolutions are managed.
Kai: They also found a way to use this information based on energy: for energies below forty MeV, you can rely solely on the neutron capture data for superior angular reconstruction.
Mira: So they’re giving us a practical rule about when to prioritize which piece of data based on the neutrino energy you are dealing with.
Lev: That’s valuable guidance for optimizing our analysis pipelines; it tells us exactly what input is most useful at different energy levels.
Kai: They also made some notes on the physical aspects, like how capture time doesn't change much with momentum, so using capture time as a proxy for momentum might be unhelpful right now.
Mira: So they are basically filtering out information that isn't actually useful for the reconstruction process and focusing only on what matters.
Lev: So they’re trying to keep the analysis focused on the most relevant physical inputs, which is smart because it saves us from chasing dead ends in our simulations.
The paper's improvements: Kai: When we talk about how this paper improves things, they are suggesting a few concrete steps for next-generation reconstruction.
Mira: They are pushing the idea to use better vertex information, suggesting that instead of just reconstructing two vertices and finding the vector between them, maybe a single algorithm to directly reconstruct the neutron capture vector could reduce detector requirements.
Lev: I agree with that direction; if we can simplify the algorithm by relying on one direct reconstruction, we might not need as much precise vertex information at all.
Kai: They’re also suggesting incorporating a model where the detected neutron capture position is treated as a three-dimensional random point x equals x y z with a normal distribution centered at the original capture position, with standard deviation calculated via delta d and chi squared value.
Mira: That sounds like they are trying to explicitly model how detector resolution smears that captured position in a way that an AI can use to correct for it.
Lev: So they are building a mechanism into the algorithm to handle the uncertainty from the vertex resolution, which is a necessary step before we can trust any of these statistical enhancements.
Kai: They also propose implementing a complete neutrino direction reconstruction algorithm that uses the updated positron energy E prime e and recalculated neutron angle theta double prime with both vertex and positron angular resolutions to compare it against a baseline where neutrino direction equals the positron direction.
Mira: That comparison is crucial because it lets you see exactly how much statistical improvement you get by combining the two signals versus just using one signal.
Lev: So this means we can benchmark our performance directly against the naive approach, which is a solid way to quantify the gain from incorporating that extra data.
Kai: They are also laying out a clear strategy for how to handle those detector effects in their reconstruction process by showing how they compare different scenarios—like using perfect resolution versus using resolutions of ten centimeters and thirty centimeters for both vertices.
Mira: That comparison is key because it shows us the cost of achieving better resolution; you can see that with a thirty centimeter resolution, the gain from neutron information disappears.
Lev: So they are giving us a clear understanding of where the practical limits are before we start designing hardware that might be overly complicated.
Kai: And they’re emphasizing that this entire methodology is designed to be scalable and extendable to future detectors like Hyper-Kamiokande, which is what makes it relevant for our long-term planning.
Mira: So the main improvement here is providing a framework that shows exactly how to use this neutron capture information in a way that's both effective and realistic for real detector constraints.
Conclusion: Kai: To wrap up, the paper "Neutron Capture Information in Improving IBD Angular Resolution" shows that using neutron capture data can enhance neutrino directionality when you look at Inverse Beta Decay events.
Mira: They demonstrated this by showing a statistical improvement, particularly for energies below forty MeV, where the use of neutron-only data outperforms the combined method.
Lev: So essentially, the main thing to take away is that you can get better directional information by incorporating neutron capture information into your analysis pipeline.
Kai: And they gave us some specific ways to do this, like using a single algorithm instead of reconstructing two vertices and just focusing on the neutron capture angle relative to the positron vector.
Mira: The limitation is clear: if you have poor vertex resolution, all that directional gain vanishes and it’s not worth pursuing if your hardware can't achieve good vertex accuracy.
Lev: So for my part, I think this paper provides a solid foundation for how we can start thinking about optimizing our error correction routines based on the insights they found about the energy regimes.
Kai: This study is the first step in considering neutron capture information to better reconstruct neutrino information in Super-Kamiokande Gd, and it sets a clear direction for what to build next.
Mira: It’s a promising path forward, and we have to keep an eye on how this methodology scales to bigger experiments like Hyper-Kamiokande.
Lev: I agree, it's the first step in considering this information to better reconstruct neutrino information in Super-Kamiokande Gd.
Qishan Liu, Kenny C. Y. Ng
Department of Physics, The Chinese University of Hong Kong · Institute of High Energy Physics, Chinese Academy of Sciences · China Center of Advanced Science and Technology
hep-ph
Submitted: 2026-06-10
Updated: 2026-11-03
Comments: 26 pages, 21 figures. Comments are welcome
License: http://arxiv.org/licenses/nonexclusive-distrib/1.0/
Importance score: 80/100
The gist: Improving the angular resolution of IBD events using neutron capture information in Super-Kamiokande investigates how incorporating neutron capture data can statistically enhance neutrino…
Key concepts
- Inverse Beta Decay (IBD)
- This is the nuclear reaction being studied where an electron interacts with a nucleus to produce a positron and an antineutrino. Measuring the direction of this event helps scientists determine the direction of the incoming neutrino, which is crucial for astrophysics.
- Neutron Capture Information
- When a neutron is captured by Gadolinium (Gd) in water, it releases detectable signals. This capture event provides extra directional information about where the neutron was located and how it moved after being captured, potentially helping to pinpoint the original neutrino direction.
- Neutron Diffusion
- Neutrons moving through water or Gd-doped water spread out over time due to random collisions, a process called diffusion. The paper models this diffusion using Geant4, showing that while it complicates reconstruction, neutrons still retain some directional hints even after diffusing.
- Angular Resolution
- This measures how precisely scientists can determine the direction of the incoming neutrino. Better angular resolution means a smaller error margin in pinpointing where the neutrino came from, which is essential for applications like searching for dark matter or supernovae.
Terminology
Summary
Improving the angular resolution of IBD events using neutron capture information in Super-Kamiokande investigates how incorporating neutron capture data can statistically enhance neutrino directionality in Inverse Beta Decay (IBD) events, which is crucial for improving event reconstruction in water Cherenkov detectors
Motivation and Background
The paper aims to study the possibilities of using neutron capture information to improve the angular resolution of IBD event reconstruction in water Cherenkov detectors. This is motivated by the fact that while positron directions are often isotropic at low energies, neutron capture information could potentially provide additional information that allows better event reconstruction. p. 0 The authors use Geant4 to simulate neutron propagation in water and show that in a wide range of neutrino energies from about 10 MeV to several hundred MeV, neutron capture information could statistically enhance the neutrino directionality, compared to positron-only inference, even with neutron diffusion considered. p. 0
Experimental Setup and Simulation
The study focuses on Super-Kamiokande (SK), a 50-kton water Cherenkov detector in Japan, which is undergoing an upgrade to incorporate 0.1% Gd into the current detector. p. 0 Gadolinium doping enhances neutron capture efficiency from approximately 50% at 0. p. 001% concentration to 75% at 0. p. 103%, with the ultimate goal of achieving a concentration of 0. p. 11% to enhance neutron tagging efficiency to 90%. p. 1 The simulation involves modeling neutron diffusion in both pure water and Gd-doped water using Geant4-v11. p. 21.1.
Kinematics and Neutron Propagation Analysis
The kinematics of IBD are described by equations (3) and (4), which involve seven parameters that need to be measured, focusing on the angle θ. In practice, neutron diffusion in water makes event-by-event reconstruction difficult, leading to an angle θ' instead of the original angle θ. Simulations show that neutrons retain some directional information after diffusion, with a slight improvement in resolution observed in Gd-loaded water. p. 2 The angular resolution of the neutron capture position as a function of neutron momentum shows that neutrons statistically retain directional information even after diffusion in water, with a slight improvement observed in Gd-loaded water. p. 2
Reconstruction Performance and Conclusions
The reconstruction process involves matching the measured neutron capture angle θ' and positron energy Ee to infer the neutrino direction ϕ' using Eq. (4). The study demonstrates that even with neutron diffusion, the inclusion of neutron capture information demonstrably enhances the reconstruction of neutrino directionality, with an average cos ψ being about 0. p. 428 for a 30 MeV neutrino energy. p. 0 For neutrinos with energies below 40 MeV, the use of neutron capture position alone yields a superior angular reconstruction performance compared to the combined approach incorporating both neutron and positron information. p. 7 However, a vertex resolution of 30 cm on both vertices results in the loss of directionality and no improvement over positron-only results. p. 7 The findings suggest that better vertex information is needed for substantial enhancement in neutrino direction reconstruction. p. 5
Implications for Future Detectors
The results have important implications for next-generation neutrino detectors, particularly Hyper-Kamiokande (HK) expected to begin operation around 2028. The methodology developed here can be extended to HK, offering valuable guidance for optimizing its physics potential. p. 7 p. 7 p. 7 This improved directional information could be important for supernova pointing applications and the search for dark matter. p. 7 The work serves as the first step in considering the neutron capture information to better reconstruct neutrino information in SK-Gd. p. 7 p. 7
Appendix Details on Capture Information
The appendix details that neutron capture time does not change much with respect to neutron momentum and is therefore unlikely to be useful for event reconstruction. The average capture distance for neutrons with a momentum of 30 MeV is approximately 7. p. 85 cm in Gd-loaded water, which is slightly shorter than the average capture distance of 10. p. 86 cm in pure water. p. 0 The authors defer the use of neutron capture distance as a proxy for neutron momentum to future work. p. 8
Appendix Details on Detector Resolution Effects
The impact of vertex resolution is significant, with a 30 cm vertex resolution leading to a deterioration in angular reconstruction when combined with other detector effects. The study shows that the improvement in IBD angular resolution gained by incorporating neutron capture information is negligible with a 30 cm vertex resolution. p. 5 The analysis confirms that the isotropic emission of positrons at these energies diminishes the effectiveness of directional information in the combined method. p. 6
Comparison Between Detector Scenarios
The reconstruction resolution is better in Gd-loaded water than in pure water, but when considering experimental resolutions, the reconstructions become comparable between Gd-loaded water and pure water. The longer capture distance in pure water helps to compensate for the loss of directional information, leading to similar reconstruction performance. p. 7 The neutron-only approach can be effectively used to reconstruct the neutrino direction for energies below 40 MeV. p. 6 p. 6 The neutron-only approach in Gd-loaded water Cherenkov detectors is analogous to those proposed in liquid scintillator detectors. p. 6
Comparison of Reconstruction Methods
The blue solid curve shows the reconstruction using positron and neutron diffusion information with perfect detector resolution, while the yellow curve represents experiments considering only the neutron capture position, excluding positron data. The red solid curve depicts the performance using only the positron direction, without accounting for any detector resolutions. p. 6 p. 6 The blue solid curve consistently outperforms the red curve, demonstrating the significant improvement in IBD angular resolution gained by incorporating neutron capture information. p. 5 The isotropic emission of positrons at these energies diminishes the effectiveness of directional information in the combined method. p. 6
Uncertainty Analysis
The uncertainty stemming from the form factor in the IBD cross section is negligible compared to detector effects, accounting for less than 1% of the overall result. The analysis results with varying neutrino energies demonstrate that the uncertainty from the cross section is negligible, accounting for less than 1% of the overall result. Consequently, this effect is excluded in reconstruction. p. 6 The impact of the positron energy resolution of 10% was not significant on the reconstruction results. p. 5
Conclusion and Future Directions
The study demonstrates a novel approach that could enhance the neutrino directionality in SK-Gd using neutron capture information. The authors motivate consideration of methods to obtain better vertex information either through better algorithms or detector modifications. p. 7 p. 7 It is suggested that it is not optimal to reconstruct two vertices and then find the vector between them, and a single algorithm to directly reconstruct the neutron capture vector may reduce detector requirements. p. 7 p. 7 The methodology developed here can be extended to HK, offering valuable guidance for optimizing its physics potential. The focus remains on neutrino directionality of IBD reactions, considering only the neutron capture angle relative to the positron vector. p. 7 The work is the first step in considering the neutron capture information to better reconstruct neutrino information in SK-Gd. p. 7
Acknowledgments and References
The authors thank Shirley Li for coming up with this idea together many years ago. The works of QSL and KCYN are supported by Croucher foundation, RGC grants (24302721, 14305822, 14308023), Joint NSFC/GRC grant (N CUHK456/22), and NSFC grant 12322517. p. 8 The paper includes numerous references from various fields including astrophysics, particle physics, and detector technology. p. 0 The list of references is provided at the end of the document. p. 2 p. 2
Appendix Details on Specific Parameters
The fitting function for neutron capture time is given by f(t) = p0 · (1 − e − t/p1) · e − t/p2 + p3. The mean capture distance for neutrons with a momentum of 30 MeV is approximately 7. p. 95 cm in Gd-loaded water. p. 2 The authors find that the capture time does not change much with respect to neutron momentum and is therefore unlikely to be useful for event reconstruction. p. 8 The capture distance could potentially be used as a proxy for the neutron momentum, but this information is deferred to future work. p. 8 The analysis confirms that the capture distance with respect to neutron momentum increases rapidly above about 30 MeV. p. 8 The study shows that neutrons are preferentially emitted along the neutrino direction, especially at lower energies. p. 6 The directional information conveyed by the neutrons is limited by their increasing emission angle deviation from the neutrino direction as neutrino energy rises. p. 6 p. 6
Reconstruction Resolution Summary
The 68% quantile of the neutrino direction reconstruction resolution is shown as a function of neutrino energy from 3 MeV to 500 MeV for different resolution scenarios. The blue solid curve shows the reconstruction using positron and neutron diffusion information with perfect detector resolution in both water(dash-dot) and Gd-loaded water(solid). p. 8 The yellow curves represent experiments considering only the neutron capture position, excluding positron data. p. 8 The red solid curve depicts the performance using only the positron direction, without accounting for any detector resolutions. The middle and right plots incorporate additional experimental resolutions: a neutron capture and IBD vertex resolution of 10 cm and 30 cm, respectively, a positron angular resolution of 10◦, and a positron energy resolution of 10%. p. 8 The average value of the neutrino direction reconstruction resolution is provided in Fig. p. 5 21 in Appendix F. p. 2 The yellow curve represents experiments considering only the neutron capture position, excluding positron data. p. 6
Summary of Key Findings
The use of neutron capture position alone yields a superior angular reconstruction performance compared to the combined approach incorporating both neutron and positron information for neutrinos with energies below 40 MeV. The directional information from neutrons is limited by their increasing emission angle deviation from the neutrino direction as neutrino energy rises. p. 6 For higher energies, the positron direction becomes more critical for achieving accurate neutrino direction reconstruction. p. 6 The neutron-only approach can be effectively used to reconstruct the neutrino direction for energies below 40 MeV. The directional information conveyed by the neutrons is limited by their increasing emission angle deviation from the neutrino direction as neutrino energy rises. The study demonstrates a novel approach that could enhance the neutrino directionality in SK-Gd using the neutron capture information. p. 7
Final Recommendations
For a vertex resolution of 30 cm on both vertices, the directionality is lost, and this approach offers no improvement over positron-only results. The authors motivate consideration of methods to obtain better vertex information either through better algorithms or detector modifications. It is suggested that it is not optimal to reconstruct two vertices and then find the vector between them, and a single algorithm to directly reconstruct the neutron capture vector may reduce detector requirements. The methodology developed here can be extended to HK, offering valuable guidance for optimizing its physics potential. Directional neutrino detection is also invaluable in the search for DM and reactor monitoring. p. 7 The work serves as the first step in considering the neutron capture information to better reconstruct neutrino information in SK-Gd. The list of references is provided at the end of the document.
Green — the paper says it, and the page is printed. Red — no passage carries it, so treat that sentence as unverified. The same check runs on your own text: check a summary against its source, $5.
Improvements for AI systems
-
Improve event reconstruction for Inverse Beta Decay (IBD) events in water Cherenkov detectors by incorporating neutron capture information, potentially allowing
neutrino directionality could be reconstructed statistically, with or without using the positron information.
This allows AI systems to estimate neutrino direction even when event-by-event reconstruction is difficult due to neutron diffusion. -
Develop a simulation module based on Geant4 that models neutron propagation in water and Gd-doped water, specifically focusing on how
neutrons retain some directional information after diffusion.
This simulation enables the AI system to use simulated capture positions to infer the initial neutrino momentum. -
Enhance vertex reconstruction algorithms by incorporating a model where the detected neutron capture position is a
3-dimensional random point x = (x, y, z) with a normal distribution centered at the original capture position
with standard deviation calculated viadelta d and chi squared value.
This allows the AI to account for detector resolution effects when using neutron capture information. -
Implement a complete neutrino direction reconstruction algorithm that utilizes
the updated positron energy E'e and the recalculated neutron angle theta'' (considering both vertex and positron angular resolutions)
to compare against a baseline whereneutrino direction = positron direction.
This allows the AI to assess the statistical enhancement of directional resolution when combining both signals. -
Create a low-energy neutrino reconstruction strategy that prioritizes
neutron-only data
for energies below 40 MeV, as this approach can yield a superior angular reconstruction performance compared to the combined method for these lower energies. This allows the AI to select the most effective input data source based on neutrino energy regimes.
Sources
- Physics with Reactor Neutrinos
- Geo-neutrinos and Earth's interior
- Evidence for oscillation of atmospheric neutrinos
- First Detailed Calculation of Atmospheric Neutrino Foregrounds to the Diffuse Supernova Neutrino Background in Super-Kamiokande
- Revisiting the Triangulation Method for Pointing to Supernova and Failed Supernova with Neutrinos
- Supernova Neutrino Neutrino Astronomy
- Timing the Neutrino Signal of a Galactic Supernova
- Can a supernova be located by its neutrinos?
- Gadolinium in water Cherenkov detectors improves detection of supernova $\nu_e$
- Observing the Next Galactic Supernova
- From eV to EeV: Neutrino Cross Sections Across Energy Scales
- An accurate evaluation of electron (anti-)neutrino scattering on nucleons
- Supernova Neutrinos: Production, Oscillations and Detection
- First measurement of reactor neutrino oscillations at JUNO
- Neutrino Physics with JUNO
- Neutrino Constraints on the Dark Matter Total Annihilation Cross Section
- Testing MeV dark matter with neutrino detectors
- Sensitivity floor for primordial black holes with neutrino searches
- Strong New Limits on Light Dark Matter from Neutrino Experiments
- Dark Matter Annihilation to Neutrinos
Related papers
- MadNIS at NLO
- The NANOGrav 15-year data set: A Limit on Continuous Spin Gravitons
- DIS-secting the universe with high-energy neutrinos
- Crowdsourcing Gravitational Waves from Superradiant Axions
- Classification of g-modes for neutron stars with a strong transition: Novel universal relation including slow stable hybrid stars
- Scalar axion field of toroidal electromagnetic pulses