Picometer control of a levitating milligram gravity sensor

arXiv:2605.28479 · quant-ph · Submitted 2026-05-27 · Read on arXiv

Listen

Radio episode about this paper

Transcript

Introduction to the show: ident: Quantum Radio. Generated commentary on the latest quantum physics and condensed matter papers.

Kai: We're looking at the paper: "Picometer control of a levitating milligram gravity sensor".

Mira: Here's the gist of the paper. Picometer control of a levitating milligram gravity sensor presents linear feedback cooling to below 2 picometer amplitude and below 10 millikelvin mode temperature for two translational modes simultaneously The experiment demonstrates a promising platform towards combining both gravitational interaction and quantum mechanical effects in a single experiment Experimental Setup Description The setup consists of a permanent magnet levitating in a superconducting trap by Meissner repulsion The permanent levitating magnet is composed of three 0.25 mm by 0.25 mm by 0.25 mm cubic neodymium iron boron parylene coated magnets stacked and glued together, using Stycast The estimated mass of this composed magnet and glass sphere is 0.35 mg The trap has an elliptical shape, 3.0 mm by 4.0 mm as the minor and major axes Vibrational noise is suppressed by a multistage mass spring system both in the vertical and lateral directions The lowest resonance frequencies are at 0.6 Hz and 1 Hz along the lateral and vertical directions, respectively Cooling Mechanism and Results The experiment uses linear feedback cooling of resonant modes at 50.6 and 68.0 Hz simultaneously Mode 3 has a resonance frequency of 50.59 Hz and a Q factor of 3.8 · 10 6 The lowest observed mode temperature for mode 3 is 7.1 mK, obtained using a gain of 930 and has a corresponding RMS amplitude of 1.6 pm Mode 4 has a resonance frequency of 67.98 Hz and a Q factor of 5.5 · 10 6 The same cooling mechanism is applied to mode 4, in this case the lowest observed mode temperature is 6.6 mK simultaneously with the 7.1 mK of mode 3 Noise Limits and Future Improvements The minimal achievable mode temperature for mode 3 with the current setup is Tmin, 3 = 0.65 mK and Nph, min, 3 = 2.7 · 10 5 The minimal achievable values with the current setup are Tmin, 4 = 1.9 mK and Nph, min, 4 = 5.7·10 5 Improvements on the achieved mode temperatures in this experiment can be achieved with lower starting temperatures and/or lower force noise The authors conclude that cooling and detection of the levitated particle in the quantum ground state should become possible by combining all these improvements Mode Identification Challenges Currently, for our system, assigning mode frequencies to their respective modes of motion is not possible with complete confidence The order, from low frequency to high frequency, we find from the analytical calculations is always: γ, z, y, x, β, α with the axes shown in Fig.

Kai: A.1 Based on coupling and sensitivity, mode 3 and mode 4 were chosen to cool using linear feedback with the piezo The order, from low frequency to high frequency, we find from the analytical calculations is always: γ, z, y, x, β, α with the axes shown in Fig.

Mira: A.1 The lowest two frequencies are believed to be rotational modes Mode Mixing and Noise Sources Many of these peaks in the spectrum can be attributed to vibrations caused by either the cooling equipment or the resonances of the vibration isolation system Upconverted noise is visible in the spectrum, and we attribute this upconversion of several peaks mixing together to work against us The most clear example can be seen in Fig.

Kai: C.3 at 51.5 Hz, where the peak displaced by 0.92 Hz to the left of the resonance at a frequency of 49.67 Hz is clearly reflected in the resonance of the magnet to 51.51 Hz The noise peak at 49.67 Hz is attributed to a snare mode of the bottom spring of the vibration isolation system The mechanical vibrations of the compressor and circulation pumps of the dilution refrigerator mix with the mechanical modes of the vibration isolation system Calibration Details The motion of the particle is calibrated using a calibration transformer The main result of this derivation is equation S12 in this publication, giving the relationship between the measured voltage in the SQUID based measurement and the motional amplitude of the magnet Calculating these values for the two cooled modes gives us dV dx = 4.7 V µm for mode 3 and dV dx = 3.0 V µm for mode 4, with a relative error of 8.5% which is dominated by the error in the mass The response of the levitating magnet to the linear feedback signal can be calculated from the following equation of motion Theoretical Framework for Mode Temperature The mode temperature is determined by Tmode = k kB Z BW / (3) The mode temperature can be converted to a phonon number (Nph) via Nph = kBTmode / ħω0 For mode 3 the lowest mode temperature corresponds to a value of Nph, 3 = 2.9 · 10 6 For mode 4 a value of Nph, 4 = 2.0 · 10 6 The zero point motion scales with ∼ 1/√mω in magnetic levitation The zero point motion scales with ∼ 1/√mω in magnetic levitation In conclusion, we have performed linear feedback cooling to a magnetically levitated particle of submillimeter scale in a superconducting trap Two different translational modes (the y- and x-mode) have simultaneously reached 7.1 mk and 6.6 mK The mass of the levitated particle is 0.38 mg and the feedback cooled phonon number is 2.9 · 10 6 and 2.0 · 10 6, for mode 3 and mode 4 respectively The authors acknowledge the support in this work by the EU Horizon Europe EIC Pathfinder project QuCoM Further improving the experiment and lowering the phonon amount towards the ground state should become possible The authors thank T.M.

Paper summary: Kai: So we're looking at the paper "Picometer control of a levitating milligram gravity sensor". What's the main thrust here?

Mira: Well, it claims they achieved linear feedback cooling for two translational modes, the x- and y-modes, simultaneously. They managed to get amplitudes below two picometers and mode temperatures below ten millikelvin.

Lev: That sounds like a lot of control over a delicate system. I wonder what kind of hardware they were actually running this on?

Kai: It's a permanent magnet levitating in a superconducting trap using Meissner repulsion, which is pretty cool because it's isolating the sensor well. They used three cubic neodymium iron boron parylene coated magnets stacked together, and the estimated mass of that setup and glass sphere is zero point three five milligram.

Mira: That mass gives you a nice scale for a gravity experiment, but they also built this system with a multistage mass spring system to suppress vibrational noise in both the vertical and lateral directions. The lowest resonance frequencies they found were at zero point six hertz and one hertz along the lateral and vertical directions <ref:2605.28479#pg2>.

Lev: So, if you're trying to run real quantum error correction on this, those vibrational modes are a major hurdle. What were their specific cooling mechanisms?

Kai: They used linear feedback cooling applied to resonant modes at fifty point six hertz and sixty-eight point zero hertz at the same time <ref:2605.28479#pg3>. They focused specifically on mode three, which has a resonance frequency of five zero point five nine hertz and a Q factor of three point eight times ten to the sixth.

Mira: And for that mode three, they observed the lowest mode temperature was seven point one millikelvin, achieved with a gain of nine thirty and an RMS amplitude of one point six picometer. Then they did the same thing for mode four at six seventy point nine eight hertz with a Q factor of five point five times ten to the sixth.

Lev: Seven millikelvin is definitely in the ballpark for what we're hoping to see in these systems, but what are the noise limits they found right now?

Kai: They found that for mode three, the minimal achievable mode temperature with their current setup is zero point six five millikelvin and a phonon number of two point seven times ten to the five. For mode four, those minimal values are one point nine millikelvin and a phonon number of five point seven times ten to the five.

Mira: So, even with that cooling, they have these noise limits they're hitting right now. The paper says improvements on vibration isolation or force noise could get them closer to the ground state.

Paper summary: Lev: That makes sense; getting from two point seven times ten to the five phonon number down to the theoretical minimum of one point zero five phonons is a big leap for real hardware. How does that compare to what we can do with current detection and force noise?

Kai: The paper indicates that with current detection and force noise, the theoretical minimum phonon limit is in the order of one point zero five phonons. But they think combining this system with their feedback cooling could get them to the ground state.

Mira: And they see this setup as a promising platform to combine gravitational interaction and quantum mechanical effects in a single experiment, since this specific setup has been used for gravitational measurements before twenty-five <ref:2605.28479#pg2,gravitational interaction and quantum mechanical effects in a single experiment>.

Lev: So, you're suggesting that by using this feedback cooling on a milligram levitated sensor, you can test gravity and quantum mechanics together?

Kai: Exactly. The main point is demonstrating this capability with submillimeter scale control. They found the motion of the particle is calibrated using a calibration transformer.

Mira: And they derived an equation, S12 in their publication, which gives the relationship between the measured voltage in a SQUID based measurement and the motional amplitude of the magnet. Calculating these values for both cooled modes gives them different sensitivities: four point seven volts micrometers for mode three and three point zero volts micrometers for mode four.

Lev: Eight point five percent relative error is mentioned, which they say is dominated by the error in the mass of the particle. That's a key caveat you have to consider when scaling this up to real experiments.

Kai: And then there's their theoretical framework for mode temperature, where Tmode equals kappa k b Z B W over three. They also converted that mode temperature into a phonon number by saying Nph equals k b Tmode over h omega zero. For mode three, the lowest mode temperature corresponds to a value of two point nine times ten to the six phonon number.

Mira: And for mode four, they find a value of two point zero times ten to the six phonons. That puts them both in that high phonon regime right now compared to what's needed for ground state physics.

Lev: So, you've got the cooling working, you've measured the resulting phonon numbers, but you still need better isolation or lower starting temperatures to get closer to that theoretical minimum of one point zero five phonons.

Paper summary: Kai: The paper does flag that improvements on achieved mode temperatures can be achieved with lower starting temperatures and/or lower force noise. The authors conclude that cooling and detection of the levitated particle in the quantum ground state should become possible by combining all these improvements.

Mira: I think what they're showing us is a working demonstration of a complex cooling technique applied to a macroscopic object for precision sensing, which is relevant whether you're studying gravity or trying to build better detectors.

Lev: It’s interesting how they are dealing with the mode identification challenges, too. They say assigning mode frequencies with complete confidence isn't possible right now. The order from low frequency to high frequency they find is always gamma, z, y, x, beta, alpha based on their analytical calculations.

Kai: And they chose modes three and four specifically to cool using linear feedback with the piezo because of coupling and sensitivity issues. The lowest two frequencies in that sequence are believed to be rotational modes.

Mira: They also discuss mode mixing as a major noise source, where many peaks can be attributed to vibrations from either the cooling equipment or the resonances of the vibration isolation system. An example they give is at five one point five hertz, where a peak displaced by zero point nine two hertz to the left of the resonance at four nine point six seven hertz is reflected in the magnet's resonance at five one point five one.

Lev: That upconverted noise from that snare mode of the bottom spring of the vibration isolation system is definitely something that would need to be addressed before you could run this on a truly sensitive quantum device.

Kai: The mechanical vibrations from the compressor and circulation pumps in the dilution refrigerator also mix with those mechanical modes of the vibration isolation system, adding to all that noise.

Mira: Overall, what this paper shows us is that achieving picometer control with milligram levitation is physically possible when you combine magnetic levitation and linear feedback cooling. It sets a baseline for combining these fields.

Lev: And while it's a promising platform, the paper clearly states their limitation: they need lower starting temperatures and/or lower force noise to get closer to the ground state, which is where the real quantum effects you want to measure live.

Kai: So, in a nutshell, they proved that this approach works for two translational modes simultaneously at seven millikelvin mode temperature. It's a big step toward using these systems for more sensitive gravity measurements or even testing quantum mechanics directly.

Conclusion: Kai: So we’ve been looking at this paper about controlling a milligram gravity sensor down to picometer scales using linear feedback cooling.

Mira: It’s about taking a really small object, like thirty-five milligrams, levitating in a magnetic trap, and trying to cool its motion using feedback.

Lev: The core claim is that they can simultaneously control two different translational motions—the x and y modes—to very low temperatures and amplitudes.

Kai: They achieved mode temperatures below ten millikelvin and amplitudes under two picometers, which is pretty impressive for a system this size.

Mira: But the real weight here is combining the gravitational interaction with these quantum mechanical cooling techniques in one setup. That's a major step towards testing gravity and quantum effects together.

Lev: It’s promising, but they also have to deal with real noise, like vibrations from the cooling equipment mixing in and messing up their measurements.

Kai: They acknowledge that they haven't hit the absolute ground state yet because they still have noise limitations to overcome.

Mira: So, what this paper really means is that we’re seeing a working demonstration of how you could use this kind of precise feedback on macroscopic objects for sensing purposes.

Lev: It sets a baseline, but it also clearly points out the next steps—we need lower starting temperatures or less force noise to get closer to those truly quantum limits.

Kai: This opens the door for using these systems not just as gravity sensors, but as platforms where we can actually probe quantum mechanics in a controlled environment.

Dennis G. Uitenbroek, Jurriaan Langendorff, Tjerk H. Oosterkamp

Leiden Institute of Physics, Leiden University

quant-ph

Submitted: 2026-05-27

Updated: 2026-11-09

Comments: Main: 9 pages including 9 figures, integrated supplementary material in the main text

License: http://creativecommons.org/licenses/by/4.0/

Importance score: 84/100

The gist: Picometer control of a levitating milligram gravity sensor presents linear feedback cooling to below 2 picometer amplitude and below 10 millikelvin mode temperature for two translational modes…

Key concepts

Linear Feedback Cooling
This is a technique used to reduce the temperature of a mechanical oscillator by applying corrective forces based on real-time measurements. In this experiment, it was used to cool two different vibrational modes of the levitating mass down to millikelvin temperatures.
Mode Temperature (Tmode)
This measures the average thermal energy within a specific vibrational mode of the sensor. It is calculated using the formula Tmode = k kB Z BW / (3), where k is Boltzmann's constant, B is the frequency, and W is related to the quality factor. Lower temperatures indicate better cooling.
Phonon Number (Nph)
This quantity relates the mode temperature to quantum mechanical energy levels. It is calculated as Nph = kBTmode / ħω0. A lower phonon number signifies that the system is closer to its quantum ground state, which is a key goal of this experiment.

Terminology

Summary

Picometer control of a levitating milligram gravity sensor presents linear feedback cooling to below 2 picometer amplitude and below 10 millikelvin mode temperature for two translational modes simultaneously The experiment demonstrates a promising platform towards combining both gravitational interaction and quantum mechanical effects in a single experiment

Experimental Setup Description

The setup consists of a permanent magnet levitating in a superconducting trap by Meissner repulsion The permanent levitating magnet is composed of three 0.25 mm by 0.25 mm by 0.25 mm cubic neodymium iron boron parylene coated magnets stacked and glued together, using Stycast The estimated mass of this composed magnet and glass sphere is 0. p. 1

Where the paper says it

25 mm cubic neodymium iron boron parylene coated magnets stacked and glued together, using Stycast. A glass sphere with a diameter of 0.

35 mg The trap has an elliptical shape, 3. p. 1
Where the paper says it

The magnet levitates in a type I superconducting trap made of tantalum, shown in Fig. This trap has an elliptical shape, 3.

0 mm by 4.0 mm as the minor and major axes Vibrational noise is suppressed by a multistage mass spring system both in the vertical and lateral directions The lowest resonance frequencies are at 0. p. 1
Where the paper says it

Vibrational noise is suppressed by a multistage mass spring system both in the vertical and lateral directions. The lowest two masses and one of the springs can be seen in Fig.

6 Hz and 1 Hz along the lateral and vertical directions, respectively

Cooling Mechanism and Results

The experiment uses linear feedback cooling of resonant modes at 50.6 and 68.0 Hz simultaneously Mode 3 has a resonance frequency of 50. p. 3

Where the paper says it

4 indicate measurements are taken simultaneously. Mode 4 has a resonance frequency of 67.

59 Hz and a Q factor of 3. p. 2
Where the paper says it

(2) For center of mass modes the thermal force noise is given by SF = 4kBTmω0/Q for rotational modes the torque noise equals Sτ = 4kBT Iω0/Q. Here, kB is the Boltzmann constant, T is the effective temperature formed by the thermodynamic temperature and vibrations at the resonance frequencies, m is the mass, ω0 is the resonance frequency, Q is the quality factor and I is the moment of inertia.

8 · 10 6 The lowest observed mode temperature for mode 3 is 7. p. 3
Where the paper says it

59 Hz and a Q factor of 3. The lowest observed mode temperature for mode 3 is 7.

1 mK, obtained using a gain of 930 and has a corresponding RMS amplitude of 1. p. 3
Where the paper says it

The lowest observed mode temperature for mode 3 is 7. 1 mK, obtained using a gain of 930 and has a corresponding RMS amplitude of 1.

6 pm Mode 4 has a resonance frequency of 67. p. 3
Where the paper says it

4 correspond to the same moment in time. Mode 3 has a resonance frequency of 50.

98 Hz and a Q factor of 5. p. 2
Where the paper says it

(2) For center of mass modes the thermal force noise is given by SF = 4kBTmω0/Q for rotational modes the torque noise equals Sτ = 4kBT Iω0/Q. Here, kB is the Boltzmann constant, T is the effective temperature formed by the thermodynamic temperature and vibrations at the resonance frequencies, m is the mass, ω0 is the resonance frequency, Q is the quality factor and I is the moment of inertia.

5 · 10 6 The same cooling mechanism is applied to mode 4, in this case the lowest observed mode temperature is 6. p. 3
Where the paper says it

98 Hz and a Q factor of 5. The same cooling mechanism is applied to mode 4, in this case the lowest observed mode temperature is 6.

6 mK simultaneously with the 7. p. 0
Where the paper says it

For future gravity experiments on quantum superpositions, such systems need to be cooled close to their ground state. To demonstrate the combination of state of the art vibration isolation, milligram levitated high Q mechanical resonators and position detection with low noise, we present linear feedback cooling of a magnetically levitated gravity sensor to below 2 picometer amplitude and below 10 millikelvin mode temperature for two translational modes (the x- and y-mode) simultaneously.

1 mK of mode 3

Noise Limits and Future Improvements

The minimal achievable mode temperature for mode 3 with the current setup is Tmin, 3 = 0.65 mK and Nph, min, 3 = 2. p. 4

Where the paper says it

4 a position noise of 1 pm/ √ Hz, and using the uncooled (gain = 0) mode temperatures for the force noise, for mode 3 this results in Tmin, 3 = 0. 65 mK and Nph, min, 3 = 2.

7 · 10 5 The minimal achievable values with the current setup are Tmin, 4 = 1. p. 4
Where the paper says it

placing the pick-up coil closer to the magnet). We can calculate the minimal achievable mode temperature and the corresponding phonon number of the current setup, due to force and detection noise: Tmin = ω0 2kB p SF Sxdet (5) Reading from both Fig.

9 mK and Nph, min, 4 = 5. p. 4
Where the paper says it

4 a position noise of 1 pm/ √ Hz, and using the uncooled (gain = 0) mode temperatures for the force noise, for mode 3 this results in Tmin, 3 = 0. 65 mK and Nph, min, 3 = 2.

7·10 5 Improvements on the achieved mode temperatures in this experiment can be achieved with lower starting temperatures and/or lower force noise The authors conclude that cooling and detection of the levitated particle in the quantum ground state should become possible by combining all these improvements

Mode Identification Challenges

Currently, for our system, assigning mode frequencies to their respective modes of motion is not possible with complete confidence The order, from low frequency to high frequency, we find from the analytical calculations is always: γ, z, y, x, β, α with the axes shown in Fig. A.1 Based on coupling and sensitivity, mode 3 and mode 4 were chosen to cool using linear feedback with the piezo The order, from low frequency to high frequency, we find from the analytical calculations is always: γ, z, y, x, β, α with the axes shown in Fig. p. 6

Where the paper says it

We have calculated the expected frequencies for the modes with analytical models [23, 32]. The order, from low frequency to high frequency, we find from the analytical calculations is always: γ, z, y, x, β, α with the axes shown in Fig.

A.1 The lowest two frequencies are believed to be rotational modes

Mode Mixing and Noise Sources

Many of these peaks in the spectrum can be attributed to vibrations caused by either the cooling equipment or the resonances of the vibration isolation system Upconverted noise is visible in the spectrum, and we attribute this upconversion of several peaks mixing together to work against us The most clear example can be seen in Fig. C.3 at 51.5 Hz, where the peak displaced by 0. p. 7

Where the paper says it

The most clear example can be seen in Fig. 5 Hz, where the peak displaced by 0.

92 Hz to the left of the resonance at a frequency of 49. p. 7
Where the paper says it

5 Hz, where the peak displaced by 0. 92 Hz to the left of the resonance at a frequency of 49.

67 Hz is clearly reflected in the resonance of the magnet to 51. p. 7
Where the paper says it

92 Hz to the left of the resonance at a frequency of 49. 67 Hz is clearly reflected in the resonance of the magnet to 51.

51 Hz The noise peak at 49. p. 7
Where the paper says it

67 Hz is clearly reflected in the resonance of the magnet to 51. This upconverted noise is cooled simultaneously with the resonance peak, meaning that the noise is coupled in through the motion of the magnet, the amplitude of the mode decreases with increasing gain and also the 51.

67 Hz is attributed to a snare mode of the bottom spring of the vibration isolation system The mechanical vibrations of the compressor and circulation pumps of the dilution refrigerator mix with the mechanical modes of the vibration isolation system

Calibration Details

The motion of the particle is calibrated using a calibration transformer The main result of this derivation is equation S12 in this publication, giving the relationship between the measured voltage in the SQUID based measurement and the motional amplitude of the magnet Calculating these values for the two cooled modes gives us dV dx = 4.7 V µm for mode 3 and dV dx = 3. p. 6

Where the paper says it

(6) Calculating these values for the two cooled modes gives us dV dx = 4. 7 V µm for mode 3 and dV dx = 3.

0 V µm for mode 4, with a relative error of 8. p. 6
Where the paper says it

7 V µm for mode 3 and dV dx = 3. 0 V µm for mode 4, with a relative error of 8.

5% which is dominated by the error in the mass The response of the levitating magnet to the linear feedback signal can be calculated from the following equation of motion

Theoretical Framework for Mode Temperature

The mode temperature is determined by Tmode = k kB Z BW / (3) The mode temperature can be converted to a phonon number (Nph) via Nph = kBTmode / ħω0 For mode 3 the lowest mode temperature corresponds to a value of Nph, 3 = 2.9 · 10 6 For mode 4 a value of Nph, 4 = 2. p. 3

Where the paper says it

Mode temperature can be converted to a phonon number (Nph) via: Nph = kBTmode ℏω0 . (4) In the case of mode 3 the lowest mode temperature corresponds to a value of Nph, 3 = 2.

0 · 10 6 The zero point motion scales with ∼ 1/√mω in magnetic levitation The zero point motion scales with ∼ 1/√mω in magnetic levitation

Conclusion

In conclusion, we have performed linear feedback cooling to a magnetically levitated particle of submillimeter scale in a superconducting trap Two different translational modes (the y- and x-mode) have simultaneously reached 7.1 mk and 6.6 mK The mass of the levitated particle is 0. p. 4

Where the paper says it

This is performed in a dry dilution refrigerator, with extensive vibration isolation. The mass of the levitated particle is 0.

38 mg and the feedback cooled phonon number is 2. p. 4
Where the paper says it

The mass of the levitated particle is 0. 38 mg and the feedback cooled phonon number is 2.

9 · 10 6 and 2.0 · 10 6, for mode 3 and mode 4 respectively The authors acknowledge the support in this work by the EU Horizon Europe EIC Pathfinder project QuCoM Further improving the experiment and lowering the phonon amount towards the ground state should become possible The authors thank T. p. 4
Where the paper says it

Combining all these improvements, cooling and detection of the levitated particle in the quantum ground state should become possible. The authors acknowledge the support in this work by the EU Horizon Europe EIC Pathfinder project QuCoM (10032223).

M. Fuchs, K. Heeck, B. Hensen, M. Camp and E. p. 4
Where the paper says it

We thank T. Camp and E.

J. Visser for useful discussions and experimental help The authors thank M. p. 4
Where the paper says it

Visser for useful discussions and experimental help. We thank M.

L. Mattana and B. p. 4
Where the paper says it

We thank M. Mattana and B.

Hensen for their careful reading of the manuscript The paper is 2605. p. 4
Where the paper says it

Mattana and B. Hensen for their careful reading of the manuscript.

Green — the paper says it, and the page is printed. Red — no passage carries it, so treat that sentence as unverified. The same check runs on your own text: check a summary against its source, $5.

Improvements for AI systems

  1. Improve quantum ground state cooling by combining linear feedback cooling with active feedback on mass spring system modes to suppress upconversion noise, as mentioned in We attribute this upconverted noise to several peaks mixing together. This allows for better control over the system's thermal environment and potentially lower final mode temperatures.

  2. Enhance gravitational sensing capabilities by achieving a higher Q factor and lower force noise by improving vibration isolation, as suggested by the need for lower starting temperatures and/or lower force noise (i.e. better vibration isolation) to reach minimal achievable mode temperatures of 0.65 mK and 1.9 mK, respectively.

  3. Increase detection sensitivity to achieve quantum ground state cooling by improving the pick-up coil placement closer to the magnet, which can be achieved by a larger coupling, i.e. placing the pick-up coil closer to the magnet. This reduces detection noise and allows for pushing towards cooling mode 3 to 27 phonons and mode 4 to 26 phonons in more extreme cases.

  4. Develop a system capable of operating near the quantum limit by improving SQUID noise, as back action noise from the SQUID will dominate over the thermal noise of the experiment at some measurement coupling, necessitating improving the SQUID noise to the quantum limit.

Abstract

Due to their exceptional isolation from the environment, magnetically levitated particles are explored as extremely sensitive mechanical sensors. For future gravity experiments on quantum superpositions, such systems need to be cooled close to their ground state. To demonstrate the combination of state of the art vibration isolation, milligram levitated high Q mechanical resonators and position detection with low noise, we present linear feedback cooling of a magnetically levitated gravity sensor to below 2 picometer amplitude and below 10 millikelvin mode temperature for two translational modes (the x - and y-mode) simultaneously. The sensor is a levitating permanent magnet in a type I superconducting trap, where its six resonance frequencies are measured with a superconducting coil coupled to a DC SQUID. This signal is measured with a lock-in amplifier and a feedback signal is sent to a piezoelectric actuator, allowing the cooling of resonant modes at 50.6 and 68.0 Hz simultaneously. These two translational modes have Q factors of 3.8 times 10 6 and 5.5 times 10 6 respectively. The experiment is mounted inside a dry dilution refrigerator where it is vibrationally attenuated with 110-130 dB at these frequencies. In this work, we discuss future improvements on the setup which may enable quantum ground state cooling on a magnetically levitated particle, that has previously been shown to be a gravitational sensor.

Related papers